Description
Wilson Marine Calorifier
Long-Life Commercial-Grade Stainless
316 standard · 2205 duplex premium
Engineered hot water for high-demand vessels
The Wilson Marine Calorifier is a heavy-duty, made-to-order hot-water calorifier engineered for superyachts and the oil & gas industry — where hot-water demand is high, redundancy matters and the installation has to answer to class. Wilson design each unit to the mechanical engineer’s specification and build it from the highest grade stainless steel, using high-quality electrical and mechanical components, so the owner gets a vessel engineered to the job rather than an off-the-shelf tank pressed into service.
★ Australian-made — factory-direct through Y3 Marine
Every Wilson calorifier is designed and built in Australia, not imported. As an authorised Wilson Marine dealer, Y3 Marine works direct with the factory — which cuts the lead time, freight and supply delays that come with overseas-sourced calorifiers, and means local build, local spares and local warranty support. Need it quickly, or built to an unusual spec? Dealing straight with the maker is the fastest route.
Specify the build — standard or premium
- Pressure vessel — 316 stainless (standard): proven marine-grade stainless, the standard build for most vessels. 2205 duplex (premium): roughly double the yield strength and far greater resistance to chloride pitting and stress-corrosion cracking — the longest-life choice for the hottest, most salt-laden, highest-duty service.
- Outer shell / casing: Colorbond® steel (standard) or 316 stainless, to suit the install environment and finish.
- Insulation: a choice of insulation options to suit the duty and minimise standing heat loss — specified per project.
Electric Systems
|
Built to demand
200 L – 10,000 L
capacities available
|
Customisable element configuration for maximum stratification
Every Wilson calorifier is built around your draw-off profile, not a fixed catalogue layout — you choose the number, rating, voltage and, critically, the height and orientation of each immersion element. Stratification is what makes a calorifier efficient: hot water rises and sits as a distinct hot layer at the top draw-off while cooler water stays below, so a well-stratified tank delivers far more usable hot water per kWh and has hot water available sooner.
- Go vertical where you can — a vertical tank stratifies far better than a horizontal one: the tall water column holds a clean hot layer at the top while the bottom stays cool, so more of the stored volume is usable. Specify vertical wherever the space allows; horizontal where headroom is the constraint.
- Stacked, staged elements — multiple elements can be arranged one above the other, each on its own set point, so the tank is brought up to temperature in stages from the top down. A ready hot volume is maintained at the top while the lower elements add capacity, and because the elements come on in sequence rather than all at once, peak electrical draw and connected load on the genset are reduced.
- Redundancy & demand — several elements mean the loss of one still leaves hot water, and the bank can be sized to meet peak galley, laundry and guest demand on a large yacht or a platform crew change.
Wilson position and stage the elements to preserve that hot layer and to match the vessel’s electrical system and demand pattern.
Heat recovery — put the heat you already make to work
A Wilson calorifier can be built with an internal heat-exchanger coil to recover waste heat from onboard systems and use it to make domestic hot water for little or no extra fuel, with electric elements as back-up (dual heating).
- Engine / genset jacket water (conventional) — the usual source and plenty of it, but intermittent: there’s only heat to recover while the machinery is running.
- HVAC & refrigeration (consistent) — the air-conditioning and refrigeration plant reject heat continuously whenever they run, which on a superyacht or a platform is effectively always. Recovering that condenser heat into the calorifier is a steady, viable source of hot water — and it offloads the chillers at the same time.
The result is lower genset load, less fuel burned purely to heat water, and the coil is removable for service. Steam heating can also be integrated where the vessel has it.
Skid-Mounted Package — Control Panel Mounted
|
Built to Capacity — 200 L to 10,000 L
|
Specification & options
| Capacity | 200 L – 10,000 L, built to order |
| Applications | superyachts and the oil & gas industry |
| Pressure vessel | 316 stainless (standard) or 2205 duplex stainless (premium) |
| Outer shell / casing | Colorbond® steel (standard) or 316 stainless |
| Insulation | Choice of insulation options, specified per duty |
| Heating | Electric; dual heating with onboard heat recovery (HVAC / refrigeration / engine); steam optional |
| Elements | Incoloy 825 flanged — customisable number, rating, voltage & location; stacked & staged for stratification |
| Configuration | Vertical (best stratification), horizontal, or skid-mounted package with pumps |
| Controls | Plug-and-play panel — separate or heater-mounted |
| Ingress protection | Custom engineered to the application |
| Certification | DNV / ABS inspection certificate available (P.O.A); Certificate of Origin & Green Passport supplied |
| Origin | Designed & manufactured in Australia |
Legislation & compliance
Which rules apply depends on the vessel’s flag — and the marine surveyor or classification society has the final say. As a guide:
- Australian commercial vessels (DCVs) are surveyed to the National Standard for Commercial Vessels (NSCV) and Australian plumbing & electrical standards. A stored-hot-water system is generally expected to carry a correctly-rated pressure / temperature relief valve (AS/NZS 1271), deliver tempered water to sanitary fixtures at a safe temperature (typically ≤ 50 °C) through a thermostatic mixing / tempering valve while storing hot enough to control Legionella (per AS/NZS 3500.4), and be electrically connected by a licensed person (AS/NZS 3000 / NSCV C5B).
- Foreign-flagged vessels (most visiting superyachts) are exempt from the NSCV and Australian domestic plumbing standards — they maintain their systems to flag-State and class requirements (DNV, ABS, Lloyd’s, etc.) under SOLAS. Wilson can supply the calorifier with a DNV / ABS inspection certificate where class requires it.
- Pressure vessel — a calorifier is a pressure vessel; Wilson design and build to recognised pressure-equipment standards, with class inspection and certification available on request.
Requirements vary by flag, class, vessel type and jurisdiction — confirm the specifics with your marine surveyor or classification society before commissioning. Y3 Marine can help scope a compliant build.
Dealer notes
- For high-demand vessels — engineered for superyachts and oil & gas; sized and staged to genuinely high, redundant hot-water loads.
- Specify vertical for stratification — vertical tanks hold a far better hot layer than horizontal; go vertical wherever headroom allows.
- Stage the elements — stacked elements on stepped set points raise temperature gradually and cut peak electrical draw on the genset.
- 316 standard, duplex premium — 316 for the standard build; step up to 2205 duplex for the longest life in the harshest duty.
- Shell & insulation to suit — Colorbond or 316 outer casing, with insulation specified to the heat-loss target.
- Recover consistent heat — engine heat is intermittent; HVAC and refrigeration reject heat continuously and make a steady recovery source that also offloads the chillers.
- Class-certifiable — DNV/ABS inspection and class approval available where the survey demands it.
- Australian-made, factory-direct — Y3 deals direct with the Australian factory, cutting lead time versus imported calorifiers; local build, support, spares and warranty, servicing Australasia and South-East Asia.
- Sizing, configuration and pricing are quoted per project — add to quote with your requirements.
Y3 Marine is an authorised Wilson Marine dealer.