Whale® Water Heater Temperature & Pressure Relief Valve (SK45360EW)

Genuine Whale temperature & pressure (T&P) relief valve for the S360EW 12V water heater. Safety-critical: vents at 99°C / 75 PSI. Replace any valve that weeps, corrodes or seizes.

Add to Quote
SKU: SP13135684 Categories: ,

Description

Genuine Whale water heater relief valve — the temperature & pressure (T&P) safety valve for the S360EW 12V marine water heater. A safety-critical component that relieves on both over-temperature and over-pressure — the last line of defence if the thermostat sticks or the system over-pressurises. Factory rated at 99°C / 75 PSI (5.2 bar).

Key details — Whale water heater relief valve

  • Function: combined temperature & pressure safety relief
  • Relief settings: 99°C / 75 PSI (5.2 bar)
  • Fits: Whale S360EW 11L 12V water heater
  • Whale part no: SK45360EW
  • BLA code: SP13135684
  • Genuine Whale service part

What it protects against

The T&P valve does two jobs at once. It vents on over-temperature (~99°C) before the water can flash to steam, and relieves the tank on over-pressure (75 PSI / 5.2 bar). Together they protect against tank rupture and scalding discharge. Never run the heater without a working, correctly-rated T&P valve.

Weeping valve? Check the accumulator first

A T&P valve that weeps a little every heating cycle is usually not faulty — it is relieving thermal expansion. As water heats it expands by 2–3%, and that extra volume has to go somewhere.

In a pressurised freshwater system the pump’s accumulator normally absorbs this expansion — its air cushion takes up the extra volume, like a small expansion tank. Two things are essential for that to work:

  • Never fit a non-return or isolating valve in the line between the water heater and the accumulator. Close that path and the tank becomes a sealed vessel — expansion is trapped and forced out through the T&P valve on every cycle. Any check valve used to stop hot water migrating into the cold lines must be positioned so the accumulator still communicates with the heated tank.
  • Keep the accumulator healthy. A waterlogged accumulator, or one with the wrong air pre-charge, cannot absorb expansion and is a common real-world cause of a weeping T&P valve. Check the air charge before condemning the valve.

If the valve still weeps once the accumulator is confirmed healthy and the line to it is open, the valve itself is due for replacement.

When to replace

Replace the T&P valve if it weeps or discharges during normal operation (once thermal expansion is ruled out), shows corrosion or scaling around the seat, has a seized lever, or fails to reseat cleanly. A relief valve must never be plugged, bypassed or swapped for a plain plug — that removes the tank’s only over-temperature and over-pressure protection.

Installation & discharge

Fit the valve in the heater’s designated relief port. Route the discharge line downhill to a safe, visible drain point, keep it full-size, and fit no valve or restriction in the discharge line. Test the valve periodically and confirm it reseats cleanly.

⚠ Australian Compliance

Marine water heaters on vessels in Australian waters require a temperature & pressure relief valve certified to AS/NZS 1271. CE-marked or international valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm compliance with your marine surveyor before commissioning.

Additional information

Brand

Whale

Function

Temperature & pressure relief valve

Relief Setting

99°C / 75 PSI (5.2 bar)

Australian Standard

AS/NZS 1271 required

Fits

Whale S360EW 11L 12V

Whale Part No

SK45360EW

BLA Code

SP13135684