Description
Whale Supersub Smart Automatic Bilge Pump
The Whale Supersub Smart combines the slim, low-profile Supersub body with Whale’s electronic field sensor — a solid-state sensor that detects rising bilge water, runs the pump and shuts it off when clear. There is no mechanical float to stick or corrode, and the Smart models include a built-in non-return valve to stop discharge water draining back into the bilge. At only around 75 mm high it keeps shallow and restricted bilges automatically dry.
Configuration Options
| Capacity | Open flow | Volts | Current | Fuse | Hose | Code |
|---|---|---|---|---|---|---|
| 650 GPH | ~41 L/min (2,460 LPH) | 12V | — | 5A | 19mm (3/4″) | |
| 1100 GPH | 66 L/min (3,960 LPH) | 12V | 4.3A | 5A | 25/28mm | |
| 1100 GPH | 66 L/min (3,960 LPH) | 24V | 2.2A | 2.5A | 25/28mm |
Built-in non-return valve on the 1100 Smart models (/). Cable 1.5 mm² (16 AWG); maximum head approximately 3 m.
Whale Build Quality
- Ultra-low-profile body — around 75 mm high; fits under soles, in lockers and in shallow bilges where a cylindrical pump won’t sit
- Clears water to a few millimetres — the flat form pumps the bilge far drier than a conventional pump
- Meets ISO 8849 — the marine standard for electric bilge pumps; CE certified
- Fuel-resistant housing — stands up to the oil and diesel film of a working bilge
- Wide anti-clog intake — large screened area resists blocking
- Solid-state field sensor — automatic switching with no moving sensing parts; nothing to jam or corrode
- Built-in non-return valve (1100 models) — stops discharge water draining back into the bilge
- Low amp draw — easy on the battery for long unattended periods
- 2-year warranty
How the automatic sensing works
The Supersub Smart senses water electronically rather than with a float. As the bilge rises the field sensor triggers the pump; as it empties the pump stops — no float to foul with the oil film and debris that collect in a bilge. The sensor draws a small standing current, so the pump must be on a permanent, fused feed (not through a panel that gets switched off). The built-in non-return valve means the water lifted up the discharge doesn’t simply run back down into the bilge each time the pump stops.
Installation Notes
- Lay the pump flat at the lowest point of the sump — the whole point of the low profile is to get the intake as close to the bilge floor as possible.
- Keep the screened intake clear of debris; the slim body pumps very low, so a clean sump pays off directly in a drier bilge.
- Run the discharge hose with a continuous upward slope to the overboard fitting; any low point forms an air lock that stops the pump priming after shutdown.
- Fit a vented loop above the waterline on the discharge to prevent back-siphon through the overboard skin fitting.
- Wire to a permanent, fused feed (direct to the battery) so the automatic sensor stays live; fuse the positive at the battery end at the rated size and keep all wiring joints above the waterline.
- Use the correct wire gauge for the run length to avoid voltage drop reducing output.
- Tolerates short dry running but should not be run dry continuously.
Nuisance water, MARPOL & oily-water discharge
These electric pumps are nuisance-water pumps. Their job is to keep the bilge dry during normal operation — clearing the everyday accumulation of rainwater, deck washdown, spray, condensation and shaft-gland or packing drips. They are not an emergency dewatering system for a holed or flooding hull; that role belongs to the manual Gusher range and to fixed emergency pumps sized to the vessel.
Because a bilge pump discharges whatever is in the bilge overboard, oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm oil, and never discharge in a port or a designated special area. Smaller craft without a separator must hold oily bilge water and land it ashore — it must not be pumped over the side. A visible diesel or oil sheen in the bilge means overboard discharge is illegal. Keep machinery-space bilges clean and oil-free, and where contamination is possible route the bilge to a holding tank or separator rather than straight overboard. This matters most with automatic pumps, which can discharge unattended — a bilge-water alarm and a clean bilge are the dealer’s standing advice.
Test it monthly
A bilge pump that fails quietly is only discovered when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: lift the float or trigger the electronic sensor, confirm the pump actually runs and moves water, and check that the strainer is clear, the non-return/check valve seats, and the discharge line runs freely with no air lock. Confirm the automatic models cut in and cut out on their own. Keep a spare strainer base and a service kit aboard so a blocked intake or tired diaphragm can be put right on the spot.
Dealer notes
- Automatic, no float needed — hands-off bilge protection in a shallow or tight sump.
- Must be on a permanent feed — don’t wire through a switched panel or the auto function is lost.
- 1100 models include a non-return valve; still fit a vented loop on the discharge above the waterline.
- Fuse per rating: 5A (12V), 2.5A (24V). For a manually switched version see the standard Supersub.
Genuine Whale (Navico). Supplied by Y3 Marine.





