Description
Whale Supersub Bilge Pump
The Whale Supersub is a slim, low-profile submersible bilge pump for tight, shallow bilges. Its flat body — only around 75 mm high — sits where a cylindrical pump physically won’t, under cabin soles, in lockers and in the shallow sumps of planing hulls, and it pumps the bilge down to a very low residual level. Every model here is a switched pump, run from an external float switch, electronic field sensor or 3-way panel.
For the same low-profile pump with built-in automatic water sensing, see the Whale Supersub Smart.
Configuration Options
| Capacity | Open flow | Volts | Fuse | Hose | Code |
|---|---|---|---|---|---|
| 500 GPH | 32 L/min (1,920 LPH) | 12V | 5A | 19mm (3/4″) | |
| 1100 GPH | 66 L/min (3,960 LPH) | 12V | 5A | 25/28mm (1″/1-1/8″) | |
| 1100 GPH | 66 L/min (3,960 LPH) | 24V | 2.5A | 25/28mm (1″/1-1/8″) |
Maximum discharge head approximately 3 m. Flow at 1 m head is roughly 400 GPH (500 model) and 750 GPH (1100 model). Cable 1.5 mm² (16 AWG).
Whale Build Quality
- Ultra-low-profile body — around 75 mm high; fits under soles, in lockers and in shallow bilges where a cylindrical pump won’t sit
- Clears water to a few millimetres — the flat form pumps the bilge far drier than a conventional pump
- Meets ISO 8849 — the marine standard for electric bilge pumps; CE certified
- Fuel-resistant housing — stands up to the oil and diesel film of a working bilge
- Wide anti-clog intake — large screened area resists blocking
- Low amp draw — easy on the battery for long unattended periods
- 2-year warranty
Why low profile matters
A standard submersible pump has to leave a pool of water beneath its intake — roughly the height of the pump body. In a shallow planing-hull sump or under a tight sole that can mean a permanently wet bilge. The Supersub’s flat form drops the intake almost to the bilge floor, so it keeps the space genuinely drier — less standing water means less corrosion, less odour and less oil/fuel sheen washing around underway. Where headroom is the constraint, it fits where nothing else will.
Installation Notes
- Lay the pump flat at the lowest point of the sump — the whole point of the low profile is to get the intake as close to the bilge floor as possible.
- Keep the screened intake clear of debris; the slim body pumps very low, so a clean sump pays off directly in a drier bilge.
- Run the discharge hose with a continuous upward slope to the overboard fitting; any low point forms an air lock that stops the pump priming after shutdown.
- Fit a vented loop above the waterline on the discharge to prevent back-siphon through the overboard skin fitting.
- Fuse the positive at the battery end at the rated size and keep all wiring joints above the waterline.
- Use the correct wire gauge for the run length to avoid voltage drop reducing output.
- Tolerates short dry running but should not be run dry continuously.
Nuisance water, MARPOL & oily-water discharge
These electric pumps are nuisance-water pumps. Their job is to keep the bilge dry during normal operation — clearing the everyday accumulation of rainwater, deck washdown, spray, condensation and shaft-gland or packing drips. They are not an emergency dewatering system for a holed or flooding hull; that role belongs to the manual Gusher range and to fixed emergency pumps sized to the vessel.
Because a bilge pump discharges whatever is in the bilge overboard, oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm oil, and never discharge in a port or a designated special area. Smaller craft without a separator must hold oily bilge water and land it ashore — it must not be pumped over the side. A visible diesel or oil sheen in the bilge means overboard discharge is illegal. Keep machinery-space bilges clean and oil-free, and where contamination is possible route the bilge to a holding tank or separator rather than straight overboard. This matters most with automatic pumps, which can discharge unattended — a bilge-water alarm and a clean bilge are the dealer’s standing advice.
Test it monthly
A bilge pump that fails quietly is only discovered when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: lift the float or trigger the electronic sensor, confirm the pump actually runs and moves water, and check that the strainer is clear, the non-return/check valve seats, and the discharge line runs freely with no air lock. Confirm the automatic models cut in and cut out on their own. Keep a spare strainer base and a service kit aboard so a blocked intake or tired diaphragm can be put right on the spot.
Dealer notes
- Switched pumps — pair each with a float switch, electronic field sensor or bilge panel; for hands-off operation choose the Supersub Smart.
- Best choice where headroom is tight or the sump is shallow; mount flat, not on edge.
- Keep the intake clear — the low profile is only an advantage if the screen stays clean.
- Fuse per rating: 5A (12V), 2.5A (24V).
Genuine Whale (Navico). Supplied by Y3 Marine.