Description
The Whale Pressure Relief Valve opens if system pressure rises beyond its set point — from thermal expansion in a water heater or a pump/switch fault — relieving the excess to protect hoses, fittings and the pump. A cheap part that prevents expensive leaks.
Dealer notes
- Fit on the pressure side of the system; essential where a calorifier/water heater can expand the water.
- Check it operates freely at service; a seized relief valve offers no protection.
Fitting & service guide — in-line valve
Fitting
- Isolate and relieve pressure on the line; have rags for residual water.
- Observe the flow-direction arrow. A non-return valve fitted backwards blocks flow completely; a relief valve must sit on the pressure side of the system.
- Connect to the hose or fitting: on barbed tails use a stainless hose clip; on BSP threads use PTFE tape or a marine thread sealant and do not overtighten plastic.
- Support the hose each side so the valve carries no strain.
Test & maintain
- Run the system and check for leaks; confirm a non-return valve holds back-flow when the pump stops, and a relief valve does not weep at normal pressure.
- At service, check the valve moves freely and is clear of debris — a check valve can trap grit, and a seized relief valve offers no protection.
Note: a non-return valve is not a substitute for a vented (anti-siphon) loop where an overboard outlet sits at or near the waterline.
Genuine Whale (Navico). Supplied by Y3 Marine.