Description
This genuine Whale set renews the plate, diaphragm and pivot of the MK5 single-action manual pump — the moving parts that wear and lose output. Fitting them restores full stroke and flow.
Dealer notes
- For the MK5 single-action pump; confirm single- vs double-action before ordering.
- Renew the valves at the same time for a complete wet-end refresh.
Fitting & service guide — diaphragm pump wet end
General guidance for servicing a Whale manual/diaphragm pump wet end. Always follow the pump’s own Whale service manual for the exact parts, orientation and torque for your model.
1. Make it safe
- Isolate the pump. Switch off and remove the fuse (electric), or remove the handle (manual), so it cannot be operated while your hands are in it.
- Isolate the line. Close the relevant seacock/valve and relieve pressure; have a bucket and rags for residual water.
- PPE for the duty. For black- or grey-water pumps wear gloves and eye protection, ventilate, and have disinfectant to hand. For an oily bilge, avoid skin contact and dispose of waste responsibly — never pump oily water over the side (MARPOL).
2. Strip the wet end
- Record orientation as you go — a quick photo at each step. Diaphragm pumps reassemble only one way.
- Release the clamp ring / clamp plate and lift off the cover (upper housing).
- Lift out the diaphragm; note which way the dome faces.
- Remove the valves (or valve plates). Note the flap/duckbill direction — inlet and outlet face opposite ways; a single reversed valve will stop the pump dead.
3. Inspect & renew
- Renew both valves together (inlet + outlet) even if only one looks worn — they age as a set, and a half-service soon fails again.
- Renew the diaphragm if it is stiff, swollen, split or distorted — a tired diaphragm is the usual cause of lost output or prime.
- Clean the seats and body, clearing scale and debris. A light smear of silicone grease on the rubber-to-plastic sealing faces (never on the valve sealing surfaces) eases assembly.
4. Reassemble & test
- Refit the valves the correct way round (flow direction), then the diaphragm (dome as noted).
- Seat the cover and tighten the clamp ring/plate evenly in a diagonal sequence — even clamping is what seals it; do not overtighten plastic.
- Reconnect the hoses, open the seacock, and re-power or refit the handle.
- Test: confirm it pulls prime, delivers full flow, and holds (no back-leak when stopped). Check for weeps around the cover and ports.
Engineer’s notes
- Service the whole wet end together — valves and diaphragm. The small extra cost of the full service kit saves a second strip-down.
- Match the material to the duty — Neoprene for general fresh/salt water; Nitrile where oil or fuel is present (oily bilges, diesel).
- If flow is still weak after a wet-end service, check the suction line for air leaks and the strainer for blockage before suspecting the pump.