Description
Whale Orca Smart Automatic Bilge Pump
The Whale Orca Smart is the self-switching member of the Orca family. A solid-state electronic field sensor built into the pump detects rising bilge water and runs the pump automatically, then shuts it down once the bilge is clear. There is no mechanical float to stick, foul or corrode and no separate switch to wire — just permanent power and a discharge. It carries the same compact footprint, wide anti-clog intake and fuel-resistant ABS body as the switched Orca.
Configuration Options
| Capacity | Open flow | Flow @1m | Volts | Current | Fuse | Hose | Code |
|---|---|---|---|---|---|---|---|
| 1300 GPH | 82 L/min (4,920 LPH) | 1,100 GPH | 12V | 5.0A | 7A | 25/28.5mm | BE1482 |
| 1300 GPH | 82 L/min (4,920 LPH) | 1,100 GPH | 24V | 2.5A | 5A | 25/28.5mm | BE1484 |
Maximum discharge head approximately 4.5 m. Catalogue codes BE1482 (12V) / BE1484 (24V).
Whale Build Quality
- Meets ISO 8849 — the marine standard for electrically driven bilge pumps; CE certified
- Fuel-resistant ABS body — withstands the oil, diesel and chemical film found in a working bilge
- Wide, free-flowing intake — large surface area resists clogging and keeps flow up as the bilge empties
- Easy-release cover — press both buttons and pull; the motor cartridge and filter area clean out without tools
- Multiple wire-exit locations — the lead can be routed to suit a tight or awkward install
- Solid-state field sensor — senses water electronically with no moving parts; nothing to jam, and immune to the oil film that fouls a float switch
- Low amp draw — easy on the battery for long unattended periods
- Marine-grade internals — ABS body, Nitrile seals and Acetal impeller for a long service life in salt water
- 3-year warranty on the 500–1300 models
How the automatic sensing works
Instead of a float, the Orca Smart uses an electronic field sensor that detects the presence of water directly. As the bilge rises the sensor triggers the pump; as it empties the pump stops. Because there are no moving sensing parts, there is nothing to corrode, stick or get fouled by debris — the classic failure modes of a float switch. The sensor draws a small standing current, so the pump must be wired to a permanent, fused feed (not through a panel that gets switched off), ideally direct to the battery via its own fuse.
Installation Notes
- Mount as low as practical in the bilge sump — the lower the pump sits, the less residual water remains after each cycle.
- Keep the strainer intake clear of frames and limber holes, with clearance around the base so debris can’t blank it off.
- Run the discharge hose with a continuous upward slope to the overboard fitting; any low point forms an air lock that stops the pump priming after shutdown.
- Fit a vented loop above the waterline on the discharge to prevent back-siphon / down-flooding through the overboard skin fitting.
- Wire to a permanent, fused feed (direct to the battery) so the automatic sensor stays live; fuse the positive at the battery end at the rated size, and keep all wiring joints above the waterline.
- Use the correct wire gauge for the run length to avoid voltage drop reducing output.
- These pumps tolerate short dry running but should not be run dry continuously.
Nuisance water, MARPOL & oily-water discharge
These electric pumps are nuisance-water pumps. Their job is to keep the bilge dry during normal operation — clearing the everyday accumulation of rainwater, deck washdown, spray, condensation and shaft-gland or packing drips. They are not an emergency dewatering system for a holed or flooding hull; that role belongs to the manual Gusher range and to fixed emergency pumps sized to the vessel.
Because a bilge pump discharges whatever is in the bilge overboard, oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm oil, and never discharge in a port or a designated special area. Smaller craft without a separator must hold oily bilge water and land it ashore — it must not be pumped over the side. A visible diesel or oil sheen in the bilge means overboard discharge is illegal. Keep machinery-space bilges clean and oil-free, and where contamination is possible route the bilge to a holding tank or separator rather than straight overboard. This matters most with automatic pumps, which can discharge unattended — a bilge-water alarm and a clean bilge are the dealer’s standing advice.
Test it monthly
A bilge pump that fails quietly is only discovered when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: lift the float or trigger the electronic sensor, confirm the pump actually runs and moves water, and check that the strainer is clear, the non-return/check valve seats, and the discharge line runs freely with no air lock. Confirm the automatic models cut in and cut out on their own. Keep a spare strainer base and a service kit aboard so a blocked intake or tired diaphragm can be put right on the spot.
Dealer notes
- Automatic, no float needed — ideal for unattended bilge protection or where a float switch would be hard to service.
- Match voltage to the vessel’s DC system and fuse per Whale’s rating (7A on 12V, 5A on 24V).
- Must be on a permanent feed — don’t wire through a switched panel or the auto function is lost.
- For a manually switched pump, or the 500/950 GPH capacities, see the standard Whale Orca.
Genuine Whale (Navico). Supplied by Y3 Marine.