Whale Microswitch Kit Universal

$14.91

Whale Microswitch Kit — Universal (AK1317). The replacement microswitch for the Whale Universal pressure pump’s built-in pressure switch — the contact that starts and stops the motor on demand. A worn microswitch causes short-cycling, a pump that won’t cut off, or won’t run; this kit restores correct operation.

Genuine Whale (Navico). Supplied by Y3 Marine.

Add to Quote
SKU: 130370-BLA Category:

Description

Whale Microswitch Kit — Universal

The microswitch is the electrical contact inside the Whale Universal pressure pump’s built-in pressure switch. It is what actually starts the motor when a tap opens and stops it at cut-off pressure, so the pump runs on demand. Like any switched contact it wears, and when it does the pump short-cycles, fails to cut off, or won’t run at all. This genuine Whale kit (AK1317) renews the microswitch and restores correct on-demand operation — far cheaper than a new pump.

Before you fit it

A flat or faulty accumulator pre-charge mimics a failing switch — both cause short-cycling. Check the accumulator (and look for small downstream leaks) before condemning the microswitch; if the pump genuinely won’t cut off, won’t start, or chatters, the microswitch is the usual culprit.

Specifications

Specification Detail
Type Replacement microswitch for the pump’s pressure switch
Fits Whale Universal pressure pump
Rating 16 A, 125/250 V AC microswitch
Scope Microswitch only — not the pump head or diaphragm
Restores Correct automatic on-demand start/stop
Code AK1317

Dealer notes

  • Common wear item on a hard-worked pressure system; a cheap fix that saves replacing the pump.
  • Rule out the accumulator first — a flat pre-charge causes the same short-cycling symptom.
  • Microswitch only — for valve/diaphragm wear, use the pump’s service kit; for the whole wet end, the Universal pump head assembly.

Fitting & service guide — pressure-switch microswitch

  1. De-power the pump and relieve system pressure before touching the wiring; confirm dead.
  2. Open the pressure-switch cover and note the wiring (photograph it) before removing the old microswitch.
  3. Fit the new microswitch, remake the connections with marine-grade crimps and heat-shrink, and keep joints clean and dry.
  4. Test: run the system and confirm the pump starts on demand and cuts off at pressure with no short-cycling. If it still cycles, re-check the accumulator pre-charge and for downstream leaks.

Genuine Whale (Navico). Supplied by Y3 Marine.

Additional information

Type

Replacement pressure-switch microswitch

Fits

Whale Universal pressure pump

Rating

16 A, 125/250 V AC

Scope

Microswitch only — not pump head/diaphragm

Restores

Automatic on-demand start/stop

Code

AK1317

Brand

Whale (Navico)