Description
Whale IC Strainer 19 mm
The Whale IC Strainer is the bilge sensing trigger of a Whale IC drainage system: a compact strainer with an Intelligent Control water sensor built into the body. Sit it in the bilge, run its 4 m cable to a remotely-mounted Gulper IC pump, and it detects rising water and signals the pump to run, then stops it once the bilge is clear. It is the accessory that makes a Gulper IC an automatic bilge pump.
Sensing is low-current and non-contact, with an on/off delay to prevent rapid cycling. The valves are non-choke and there is no filter element to clean or float to stick — the classic bilge-switch failure modes are simply not there.
How the Whale IC system fits together
Whale Intelligent Control (IC) is a float-free drainage system. The control electronics live in the Gulper IC pump, and a sensor detects water without touching it, signalling the pump to run and then stop when the water clears. Every install is one pump plus the one sensor that matches the job:
| Application | Sensor | What it does |
|---|---|---|
| Bilge | IC Strainer 19 mm | Sits in the bilge, senses rising water — turns the Gulper IC into an automatic bilge pump |
| Shower | Gulley IC Shower Sensor | Shower-tray drain body with the sensor built into it |
| Grey waste | IC Two-Way Manifold | Joins two drain lines and senses the combined grey-water level |
The Gulper IC Adapter (Deutsch ↔ ODS) joins mismatched harness plugs when mixing or retrofitting IC parts. Sensing is non-contact — no float to stick, no probe to foul — with a built-in on/off delay to prevent short-cycling.
Specifications
| Specification | Detail |
|---|---|
| Role | IC bilge sensor + strainer (non-contact water sensing) |
| Hose | 19 mm |
| Cable | 4 m to the pump |
| Requires | A Gulper IC pump to do the pumping |
| Maintenance | No filter element; no float |
Dealer notes
- Sensor only — pair it with a Gulper IC pump; it is the bilge alternative to the shower Gulley IC or the grey-waste Two-Way Manifold.
- Site it at the low point of the bilge so it picks up water early; keep the cable run and connector above the waterline.
- Nuisance-water duty — it is not an emergency dewatering sensor. Test it with the pump monthly.
Fitting notes
- Place the strainer at the bilge low point where water collects first; secure it so it cannot float or shift.
- Run the 4 m cable to the pump; keep the connector above the waterline.
- Plumb the 19 mm suction hose from the strainer to the pump inlet and secure with 316 stainless-steel hose clamps.
- Test: raise the bilge water — the pump should start, then stop on the delay once clear.
Genuine Whale (Navico). Supplied by Y3 Marine.