Description
Whale Gulper IC Pump
The Whale Gulper IC is the pump at the heart of Whale’s Intelligent Control drainage range. It is a compact, remote-mounting diaphragm pump that can be fitted away from the water it moves — in a locker or under a sole — and it carries the IC control electronics on board. On its own it will not run: it waits for an IC sensor to signal that water is present, then pumps, and stops when the water clears.
That one pump covers three jobs depending on which sensor you pair with it — automatic bilge, shower drainage, or grey-waste removal — which is what makes the IC range so flexible. The valves are non-choke (they pass hair and soft solids), the head rotates to suit the install, and the pump is self-priming and safe to run dry.
How the Whale IC system fits together
Whale Intelligent Control (IC) is a float-free drainage system. The control electronics live in the Gulper IC pump, and a sensor detects water without touching it, signalling the pump to run and then stop when the water clears. Every install is one pump plus the one sensor that matches the job:
| Application | Sensor | What it does |
|---|---|---|
| Bilge | IC Strainer 19 mm | Sits in the bilge, senses rising water — turns the Gulper IC into an automatic bilge pump |
| Shower | Gulley IC Shower Sensor | Shower-tray drain body with the sensor built into it |
| Grey waste | IC Two-Way Manifold | Joins two drain lines and senses the combined grey-water level |
The Gulper IC Adapter (Deutsch ↔ ODS) joins mismatched harness plugs when mixing or retrofitting IC parts. Sensing is non-contact — no float to stick, no probe to foul — with a built-in on/off delay to prevent short-cycling.
Specifications
| Specification | Detail |
|---|---|
| Type | Remote-mount diaphragm waste / bilge pump — Intelligent Control |
| Flow | Up to 19 L/min (5 GPM) |
| Control | Built-in IC — low-voltage switching, runs only on an IC sensor signal (no float) |
| Priming | Self-priming; safe to run dry |
| Valves | Non-choke — passes hair & soft solids |
| Bilge duty | Primary bilge pump to 12 m / secondary bilge pump on any vessel |
| Voltage | 12V or 24V (select below) |
| Standard | Performance meets ISO 15083 |
| Code | Whale BP2082B (12V) / BP2084B (24V) |
Dealer notes
- Buy the matching sensor with the pump — the Gulper IC does nothing until a sensor is wired in. See the table above for which sensor suits bilge, shower or grey-waste duty.
- Mount it high and dry; its self-priming lets it sit above the water it clears, keeping the motor out of the bilge.
- As a bilge pump it is an automatic secondary on any vessel, or the primary on craft to ~12 m — it is a nuisance-water pump, not an emergency dewatering pump.
- Mixing an older sensor or harness? The Gulper IC Adapter sorts Deutsch ↔ ODS plug mismatches.
Fitting notes
- Mount the pump in a dry, accessible spot with the head rotated to line up your inlet and outlet hose runs.
- Run the sensor cable back to the pump; keep connectors above the waterline and support the hoses, securing them with 316 stainless-steel hose clamps.
- Wire to a fused supply (marine-grade crimps and heat-shrink) at the correct voltage; observe polarity.
- Test: trigger the sensor (raise bilge water / run the shower) — the pump should start, then stop on the built-in delay once clear.
Bilge discharge (MARPOL): overboard discharge of oily bilge water is restricted under MARPOL Annex I. Keep the bilge clean and oil-free, and test the pump and its sensor monthly.