Whale® Electric Water Heater 12V — 11L

$2,382.33

12V DC electric marine water heater for tenders, RIBs and small sailing yachts where there’s no shore power, genset or inverter. Runs directly off the vessel’s battery bank, heating a full 11L tank in around an hour. ABYC E-11 ignition-protected, ALCLAD tank, integrated T&P relief valve and thermal cut-out. Compact horizontal mounting for tight bilge and locker spaces.

Available on back-order

Add to Quote
SKU: 135680 Categories: ,

Description

📦 Dispatch & Availability: This item is available on back order. Please allow up to 10 business days to dispatch from the date of order.

The Whale electric water heater (S360EW) is a 12V DC marine unit built for one specific job: delivering hot water aboard tenders, RIBs, small sailing yachts and other small craft that carry no AC shore power, generator or inverter. It runs directly off the vessel’s 12V battery bank, so hot water becomes available without adding an inverter or running the main engine. Compact and horizontally mounted, it drops into tight bilge and locker spaces where a conventional calorifier simply won’t fit — a practical, self-contained solution for deck showers, wash-down and galley duty on smaller vessels and superyacht tenders.

Choosing the right Whale electric water heater

Marine hot-water systems fall into three broad types, and matching the heater to the vessel’s power architecture is where most specification errors happen:

  • Engine-coolant (heat-exchanger) calorifiers recover waste heat from the engine’s cooling circuit — efficient underway, but they need the engine running and a coil plumbed into the coolant loop.
  • AC element calorifiers heat fast on 230/240V, but depend on shore power, a genset or a substantial inverter.
  • DC direct heaters like the S360EW carry their own element and run straight off the battery — the only practical option on a craft with no AC source at all.

The S360EW sits firmly in that third category. It’s not intended to replace a large accommodation calorifier; it’s the correct tool when the vessel has 12V and nothing else.

Key Features

  • Voltage: 12V DC — direct battery operation, no inverter or genset required
  • Tank capacity: 11L
  • Tank material: ALCLAD (aluminium-clad) pressure vessel
  • Mounting: Horizontal, suited to shallow bilge and locker installs
  • Connections: ½” NPT female
  • Current draw: <30A (35A fuse) — plan cable sizing and a dedicated protected circuit accordingly
  • Ignition protection: ABYC E-11 compliant — essential in petrol/outboard engine spaces
  • Safety: Integrated temperature & pressure (T&P) relief valve (99°C / 75 PSI / 5.2 bar), thermal cut-out, low-current switching, heating-indication output
  • Max tested pressure: 300 PSI (20.7 bar)
  • Dimensions (W × D × H): 368 × 356 × 330 mm
  • Weight: 6.8 kg
  • Warranty: 2 years
  • BLA Code: 135680

Recovery and electrical load — what to expect

A DC element is limited by the current the system can safely carry, so a direct 12V heater recovers more slowly than an AC unit and draws meaningful current while heating. At under 30A the S360EW needs correctly sized cable, a dedicated 35A-protected circuit, and a battery bank (and charging source) able to sustain the load — this is the single most common install oversight. Sized and wired correctly, it heats a full tank in around an hour, which is ample for intermittent deck-shower and wash-down use.

Typical applications

  • Superyacht tenders, chase boats and toys requiring hot water independent of the mothership
  • RIBs and centre-consoles with 12V-only electrical systems
  • Small sailing yachts (20–33 ft / 6–10 m) with no genset or inverter
  • Deck showers and wash-down stations — rinsing dive gear, wetsuits and crew
  • Day boats and small commercial craft with no genset or inverter installed

Installation & compatibility notes

  • Integrates with the Whale 15mm Quick Connect plumbing system, the Whale Watermaster automatic pressure pump, and the Whale Twist® deck shower
  • Mount horizontally on a solid bearer; keep the T&P valve discharge routed to a safe drain point
  • Fit an accumulator/pressure pump upstream for stable delivery
  • Confirm battery capacity, charging and cable runs before commissioning — see the electrical note above

⚠ Australian Installation Requirements

All marine water heaters installed aboard vessels in Australian waters must comply with the following. Failure to comply may constitute a vessel safety deficiency under the National Standard for Commercial Vessels (NSCV C5A).

  • Temperature & Pressure Relief Valve (T&PRV): A T&PRV rated and certified to AS/NZS 1271 must be fitted. CE-marked or international relief valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm compliance with your marine surveyor before commissioning.
  • Thermostatic Mixing Valve (TMV): A TMV must be installed at all hot water outlets to limit delivery temperature and prevent scalding — required on all commercial and passenger vessels.

Compliance is the responsibility of the installer and vessel operator. Y3 Marine recommends installation by a licensed marine plumber or qualified engineer.

Additional information

Weight 6.8 kg
Dimensions 356 × 368 × 330 mm
Brand

Whale

Model

S360EW

Voltage

12V DC

Tank Capacity

11 L

Tank Material

ALCLAD (aluminium-clad)

Mounting

Horizontal

Connections

1/2" NPT Female

Current Draw

<30A (35A fuse)

Ignition Protection

ABYC E-11

Safety Features

Integrated T&P relief valve, thermal cut-out, low-current switching, heating-indication output

T&P Relief Valve

99°C / 75 PSI (5.2 bar)

Max Tested Pressure

300 PSI (20.7 bar)

Warranty

2 years

BLA Code

135680