Description
Victor Marine FBBR Sewage Treatment Plant
The Victor Marine FBBR (Fixed Bed Bio Film Reactor) is a UK-built biological marine sewage treatment plant — a low-power, low-maintenance alternative to chemical-physical plants. It treats both black and grey water to a standard that permits overboard discharge where the law allows, and is Bureau Veritas type-approved to IMO MEPC.227(64) (excluding §4.2) and MEPC.159(55), with MED certification.
How it works
Treatment runs in five stages with no high-speed moving parts:
- Fixed-Bed BioReactor — bacteria grow as a biofilm on a high-surface-area structured media bed, aerated by an integral air blower; the biofilm digests the waste (an improved trickling-filter principle).
- Settlement tank with tube settlers to clarify the effluent.
- Chlorination by tablet dispenser (easy to refill without stopping the plant).
- Chlorine contact / discharge tank.
- Dechlorination by tablet, to meet the IMO residual-chlorine limit before the discharge pump sends it overboard.
Transfers are by gravity and airlift — only the inlet, blower and discharge pump use power — so energy consumption is very low. The plant is fully automatic under PLC-HMI control, with an integrated sludge consolidation and transfer system.
Model range
| Model | Persons | Hydraulic load (m³/day) | Biological load (kg BOD/day) | Dry weight (kg) |
|---|---|---|---|---|
| FBBR Mini | ~9 | 1.8 | 0.63 | 490 |
| FBBR 12 | 12 | 2.4 | — | — |
| FBBR 15 | 15 | 3.0 | — | — |
| FBBR 30 | 30 | 6.0 | — | — |
| FBBR 50 | 50 | 10.0 | 3.50 | 1500 |
— = figure on request. Size by peak persons aboard / daily sewage load.
Why biological (FBBR)?
- No membranes, no backwashing, no cleaning cycles — and no high-speed moving parts, so low maintenance and lifetime cost.
- Very low power — gravity / airlift transfers; only the blower and pumps draw current.
- Few consumables — chlorine & dechlorine tablets, air filters, the odd solenoid/gasket/level switch (ex-stock worldwide).
- Handles a gravity or vacuum feed; turnkey or modular for easier install.
Discharge, MARPOL & certification
Marine sewage is controlled under MARPOL Annex IV. A type-approved plant lets a vessel discharge treated effluent outside prohibited zones. The FBBR is certified to MEPC.227(64) excluding §4.2; if you need the stricter §4.2 Special-Areas standard, see the Ecomar S series. Always confirm acceptance with your flag / class and AMSA for the operating area.
Dealer notes
- Quote-only, via AMI — send crew number, vessel type and operating area and we’ll size the plant and quote.
- Size by persons — the model number is roughly the person capacity (Mini ~9, up to 50).
- 3-phase 380–460 V supply; plan the space (allow maintenance access) and feed (gravity or vacuum).
- Waste must be macerated to the plant’s requirement — a macerator is an optional item.
- Y3 Marine supports selection, install and commissioning with Chief-Engineer-level back-up.
Genuine Victor Marine. Supplied by Y3 Marine.