Description
📦 Dispatch & Availability: Standard Vetus exhaust items are available on back order and typically dispatch within 10 business days. Non-standard or larger items have a lead time of approximately 12 weeks from order.
The VETUS marine muffler (MP Series, plastic) delivers additional noise attenuation downstream of a waterlock or mixing elbow by creating turbulent mixing of injected cooling water and exhaust gas inside its polypropylene housing. The low-restriction flow path keeps backpressure within safe limits while the water-absorb design effectively dampens combustion noise — making it a practical upgrade on any wet exhaust system where quieter operation is a priority. Seven sizes cover engines from small auxiliaries up to 114 kW (155 hp), fitting standard VETUS exhaust hose diameters throughout.
VETUS marine muffler — model selection guide
| Model | SKU | Hose Diameter | Max Engine Power | Body Dimensions (L × H) |
|---|---|---|---|---|
| MP40 | DEMPMP40 | 40mm (1-9/16″) | 18 kW / 24.5 hp | 368 × 158mm |
| MP45 | DEMPMP45 | 45mm (1-3/4″) | 22 kW / 30 hp | 368 × 158mm |
| MP50 | DEMPMP50 | 51mm (2″) | 28 kW / 38 hp | 368 × 158mm |
| MP60 | DEMPMP60 | 60mm (2-3/8″) | 39 kW / 53 hp | 368 × 158mm |
| MP75 | DEMPMP75 | 76mm (3″) | 63 kW / 86 hp | 456 × 180mm |
| MP90 | DEMPMP90 | 90mm (3-1/2″) | 89 kW / 121 hp | 456 × 180mm |
| MP100 | DEMPMP100 | 102mm (4″) | 114 kW / 155 hp | 580 × 202mm |
Engine power ratings are based on an allowable backpressure of 0.1 bar. Size up if your installation has a long exhaust run or high backpressure.
Key Features
- Additional noise reduction — turbulent water mixing inside the housing damps combustion and flow noise beyond what a waterlock alone achieves
- Low backpressure design — polypropylene construction with smooth internal flow path offers minimal resistance to exhaust gas flow
- Flexible positioning — can be installed before or after the gooseneck; fitting after the gooseneck reduces gurgling at the transom
- Mounting brackets included — MP40 to MP90 fitted with two mounting ears; MP100 supplied with Ty-rap® straps
- Wide size range — 7 models cover 40–102mm hose and engines up to 114 kW (155 hp)
- Max continuous operating temperature: 70°C — suitable for all standard wet exhaust applications; install a temperature alarm as a safeguard
Typical Superyacht Applications
- Auxiliary diesel generator exhaust systems where additional silencing is required in accommodation spaces
- Tender and chase-boat engines where a compact, lightweight muffler is needed
- Main propulsion wet exhaust systems with noise-sensitive crew quarters near the engine room
- Retrofit noise-reduction upgrade on existing waterlock systems
Complete Your Wet Exhaust System
The VETUS MP muffler is a supplementary silencing component — it works in series with a waterlock (LP, NLP, or MG series) to provide a second stage of noise reduction. A complete wet exhaust system typically includes a mixing elbow, waterlock, exhaust hose, muffler (optional), gooseneck, and transom connection. The muffler is not a substitute for a waterlock.
Typical wet exhaust flow: Engine mixing elbow → Exhaust hose → Waterlock → Exhaust hose → Muffler (optional) → Gooseneck → Exhaust hose → Transom connection
| Component | Role | Required? |
|---|---|---|
| Mixing elbow (injection bend) | Injects cooling water into exhaust gas at the manifold | Yes |
| Waterlock (LP / NLP / MG series) | Traps and drains injected water; primary noise reduction | Yes |
| Exhaust hose | Flexible wet-exhaust rated conduit between components | Yes |
| MP Series muffler | Additional in-line noise attenuation stage | Optional |
| Gooseneck (LT series) | Anti-syphon loop to prevent water re-entry | Recommended |
| Transom connection | Hull exit fitting for the exhaust discharge | Yes |
Installation & Compatibility Notes
- Match hose size exactly — select the model whose hose diameter matches your existing exhaust hose; do not reduce or increase hose diameter at the muffler
- Support the muffler — the housing fills with water during operation, significantly increasing weight; always provide adequate structural support
- Hose connections — use two stainless steel 12mm-wide hose clamps per connection; use water or soap to ease fitting — never use grease or oil
- Exhaust routing — the highest point in the exhaust line downstream of the muffler must not exceed 150cm above the muffler base; the pipe between the muffler and the highest point must not exceed 300cm
- Winter lay-up — drain the muffler completely before storage to prevent frost damage
- Use VETUS exhaust hose — reinforced, rated to 100°C, resistant to exhaust gas and oil; do not substitute with standard water hose
- Temperature alarm — VETUS strongly recommends fitting an exhaust temperature alarm on all wet exhaust systems