VETUS Exhaust Gas and Cooling Water Separator (LGS Series)

Price range: $649.69 through $801.77

VETUS LGS exhaust gas and cooling water separator — separates the wet exhaust stream into independent gas and water discharge paths. Replaces the gooseneck when mounted vertically at least 45cm above the waterline. Dual 360° rotatable hose connections. SS mounting strap included. Six sizes, 40–90mm, covering engines up to 93 kW (125 hp).

Add to Quote
SKU: N/A Category:

Description

📦 Dispatch & Availability: Standard Vetus exhaust items are available on back order and typically dispatch within 10 business days. Non-standard or larger items have a lead time of approximately 12 weeks from order.

The VETUS gas water separator (LGS series, exhaust and cooling water) takes the mixed wet exhaust stream from the waterlock and splits it into two separate discharge paths: exhaust gas exits via the upper hose connection and out through the vessel’s exhaust outlet, while cooling water drains away through a dedicated skin fitting with valve. Installed vertically above the waterline, the LGS replaces the gooseneck entirely — its elevated position creates the required anti-syphon loop, preventing seawater from back-flooding the engine. The dual 360° rotatable hose connections can be configured as either inlet or outlet, giving maximum flexibility in confined engine room layouts. Six sizes cover 40–90mm exhaust hose with separation capacities from 7 to 20 litres, handling auxiliary gensets through to main propulsion diesels up to 93 kW (125 hp).

VETUS gas water separator — model selection guide

Model SKU Hose Ø (ID) Drain Hose Volume Max Engine Power
LGS4038 LGS4038 40mm (1-9/16″) 38mm (1-1/2″) 7L 18 kW / 25 hp
LGS4538 LGS4538 45mm (1-3/4″) 38mm (1-1/2″) 7L 23 kW / 32 hp
LGS5038 LGS5038 50mm (2″) 38mm (1-1/2″) 7L 29 kW / 40 hp
LGS6050 LGS6050 60mm (2-3/8″) 50mm (2″) 12L 40 kW / 55 hp
LGS7550 LGS7550 75mm (3″) 50mm (2″) 12L 65 kW / 90 hp
LGS9075 LGS9075 90mm (3-1/2″) 75mm (3″) 20L 93 kW / 125 hp

Engine power ratings based on 0.1 bar allowable backpressure (VETUS installation manual 030411.02). Max continuous operating temperature: 70°C.

Key Features

  • Separates exhaust gas from cooling water — splits the wet exhaust stream into two paths: exhaust gas exits via the upper hose connection, cooling water drains through a dedicated skin fitting; ideal where a submerged or low exhaust outlet is impractical
  • Replaces the gooseneck — when installed vertically with its highest point at least 45cm above the waterline, the LGS provides the required anti-syphon protection without a separate gooseneck loop
  • Dual 360° rotatable hose connections — both hose tails rotate independently and either can function as inlet or outlet, allowing the unit to be oriented in almost any direction in confined bilge or engine room spaces
  • Dedicated cooling water drain — cooling water discharges through a threaded drain port (G1½″, G2″, or G3″ depending on model) to a separate skin fitting with valve; eliminates mixed exhaust discharge from the transom
  • Valve safety requirement — a valve in the cooling water drain line must be closed when the engine is stopped, preventing water entry when sailing under canvas or at rest
  • Corrosion-free polypropylene — unaffected by salt water, exhaust condensate, and bilge environment
  • Stainless steel mounting strap included — mount vertically against a solid bulkhead; unit contains water in operation and the strap-mount transfers the load correctly
  • Six sizes, 40–90mm — covers small auxiliary engines through to main propulsion diesels up to 93 kW (125 hp)

Typical Applications

  • Generator set installations where separate discharge paths are needed — gensets aboard superyachts are often positioned such that the exhaust gas and cooling water need to exit at different hull locations; the LGS handles the separation cleanly downstream of the waterlock
  • Sailing yachts where the transom outlet may be submerged when heeling — separate gas and water discharge paths eliminate the backflow risk that a combined wet transom outlet cannot prevent on a hard tack or in heavy seas
  • Tenders and support vessels with low transom outlets — when a below- or near-waterline exhaust exit is unavoidable, the LGS allows cooling water to drain through a dedicated seacock while exhaust gas exits at a higher point on the hull
  • Installations where gas and water must exit at different hull locations — the LGS handles the separation so each stream is routed to its optimal outlet; eliminates the need to route both streams to a single combined transom fitting

Complete Your Wet Exhaust System

The VETUS LGS gas/water separator sits downstream of the waterlock and replaces the gooseneck in installations where separated gas and water discharge is needed. A waterlock (LP, NLP, or NLP3 series) is still required upstream to provide primary noise reduction and initial water separation. The LGS then separates the residual mixed stream for clean individual discharge.

Typical wet exhaust flow with LGS: Engine mixing elbow → Exhaust hose → Waterlock (LP/NLP/NLP3) → Exhaust hose → LGS Gas/Water Separator → [Exhaust gas: hose to hull exit] + [Cooling water: hose to skin fitting with valve]

Component Role Required?
Mixing elbow (injection bend) Injects cooling water into exhaust gas at the manifold Yes
Waterlock (LP / NLP / NLP3 series) Traps water; primary noise reduction Yes
Exhaust hose Flexible wet-exhaust rated conduit between components Yes
LGS Gas/Water Separator Separates exhaust gas and cooling water; replaces gooseneck Yes (this unit)
Skin fitting with valve Overboard discharge for separated cooling water Yes — not included
Transom connection Hull exit for separated exhaust gas discharge Yes

Installation & Compatibility Notes

  • Mount vertically — the LGS must be installed as vertically as possible, above the waterline; the highest point of the unit must be at least 45cm (18″) above the waterline to function as the anti-syphon loop
  • Sailboats: install amidships — minimises the reduction in effective height when heeling; a unit mounted at the stern can lose considerable anti-syphon height on a hard tack
  • Close to the waterlock — install the LGS as close as possible to the waterlock to minimise water remaining in the hose between the two when the engine shuts down
  • Cooling water drain valve — mandatory — fit a valve in the drain line between the LGS and the skin fitting; this valve must be closed whenever the engine is not running
  • Drain skin fitting placement — the skin fitting may be above or a maximum of 7.5cm (3″) below the waterline; must not be in a location where forward speed creates back-pressure into the unit
  • Rotatable connections — unscrew hose clamps before rotating hose tails; re-tighten to 5–6 Nm (LGS40/45/50) or 0.4 Nm (LGS60/75/90)
  • Two stainless steel 12mm hose clamps per connection — use water or soap as lubricant during fitting; never use grease or oil-based products
  • Use VETUS exhaust hose — reinforced, rated to 100°C, resistant to exhaust gas and oil; do not substitute with standard water hose
  • Max continuous operating temperature: 70°C — fit a temperature alarm on the engine exhaust hose

Additional information

Model

LGS4038 — 40mm hose (38mm drain, 7L), LGS4538 — 45mm hose (38mm drain, 7L), LGS5038 — 50mm hose (38mm drain, 7L), LGS6050 — 60mm hose (50mm drain, 12L), LGS7550 — 75mm hose (50mm drain, 12L), LGS9075 — 90mm hose (75mm drain, 20L)

Material

Polypropylene (corrosion-free synthetic)

Max Operating Temperature

70°C (158°F)

Hose Connection

Barbed hose tail — 2× 12mm SS clamps per end (recommended)

Rotation

Both hose connections — 360° rotatable, either can be in or out

Mounting

Vertical — SS mounting strap included

Min Height Above Waterline

450mm (18") — replaces gooseneck

Drain Connection

Skin fitting with valve required — not included (G1½", G2", or G3" depending on model)

Compatible Hose

VETUS reinforced exhaust hose (heat-resistant to 100°C)

Brand

VETUS

Brand

Vetus