Description
📦 Dispatch & Availability: Standard Vetus exhaust items are available on back order and typically dispatch within 10 business days. Non-standard or larger items have a lead time of approximately 12 weeks from order.
The VETUS exhaust gooseneck creates the anti-syphon loop required in any wet exhaust system where the engine’s cooling water injection point is less than 15 cm above the waterline, or on any sailing yacht. By routing the exhaust hose up and over a high point at least 45 cm above the waterline, the gooseneck prevents seawater from syphoning back through the exhaust and into the engine when the engine is shut down. Available in two families: the compact WLOCKLT series for 40–60mm hose and the larger LT series (supplied with stainless steel AISI 316 mounting brackets) for 65–152mm hose covering auxiliary diesels up to 114 kW. Several LT models are available with a stepped outlet for systems where the outlet hose is larger than the inlet.
VETUS exhaust gooseneck — model selection guide
| Model | SKU | Inlet Ø | Outlet Ø | Height | Series / Notes |
|---|---|---|---|---|---|
| WLOCKLT Series — Compact plastic gooseneck, 40–60mm (no mounting brackets) | |||||
| WLOCKLT40 | WLOCKLT40 | 40mm (1-9/16″) | 40mm | 390mm | Horizontal outlet; can be modified to vertical |
| WLOCKLT45 | WLOCKLT45 | 45mm (1-3/4″) | 45mm | 390mm | Horizontal outlet; can be modified to vertical |
| WLOCKLT50 | WLOCKLT50 | 51mm (2″) | 51mm | 390mm | Horizontal outlet; can be modified to vertical |
| WLOCKLT60 | WLOCKLT60 | 60mm (2-3/8″) | 60mm | 390mm | Horizontal outlet; can be modified to vertical |
| LT Series — Plastic gooseneck with SS AISI 316 mounting brackets, 65–152mm | |||||
| LT6565 | LT6565 | 65mm (2-17/32″) | 65mm | 500mm | Equal inlet/outlet |
| LT6575 | LT6575 | 65mm (2-17/32″) | 75mm (2-15/16″) | 500mm | Stepped outlet — NLP65 waterlock to 75mm outlet |
| LT7575 | LT7575 | 75mm (2-15/16″) | 75mm | 500mm | Equal inlet/outlet |
| LT9090 | LT9090 | 90mm (3-1/2″) | 90mm | 525mm | Equal inlet/outlet |
| LT90110 | LT90110 | 90mm (3-1/2″) | 110mm (4-5/16″) | 525mm | Stepped outlet — pairs with 110mm transom fitting |
| LT102 | LT102 | 102mm (4″) | 102mm | 525mm | Equal inlet/outlet |
| LT110110 | LT110110 | 110mm (4-5/16″) | 110mm | 525mm | Equal inlet/outlet |
| LT127 | LT127 | 127mm (5″) | 127mm | 565mm | Equal inlet/outlet; large superyacht engines |
| LT152 | LT152 | 152mm (6″) | 152mm | 565mm | Equal inlet/outlet; large superyacht engines |
Hose sizing guide (0.1 bar backpressure): 40mm→18 kW, 45mm→22 kW, 51mm→28 kW, 60mm→39 kW, 76mm→63 kW, 90mm→89 kW, 102mm→114 kW. Match gooseneck inlet to your existing exhaust hose diameter. All LT models supplied with SS AISI 316 mounting brackets.
WLOCKLT vs LT — Which to Choose?
Choose WLOCKLT for 40–60mm hose installations. This compact series mounts without separate brackets and can be modified to a vertical outlet by cutting section A — useful when the gooseneck must exit upward through a deck fitting or bulkhead rather than horizontal toward the transom.
Choose LT for 65mm and above. The LT series is larger, heavier, and comes with stainless steel mounting brackets for secure installation. Several LT models offer a stepped outlet (LT6575, LT90110) to transition from one hose diameter to a larger outlet — useful when the waterlock outlet hose is smaller than the transom connection.
Key Features
- Anti-syphon protection — raises the exhaust line at least 45 cm above the waterline, preventing cooling water from syphoning back into the engine on shutdown; mandatory on any sailing yacht and on any installation where the water injection point is within 15 cm of the waterline
- Stepped outlet variants available — LT6575 (65mm in / 75mm out) and LT90110 (90mm in / 110mm out) allow a smooth diameter transition when the transom connection or downstream hose is larger than the waterlock outlet
- WLOCKLT: modifiable to vertical outlet — section A can be sawn off to convert the horizontal outlet to a vertical one on WLOCKLT40/45/50/60 models, enabling through-deck installations
- LT: SS AISI 316 mounting brackets supplied — heavy-gauge stainless steel mounting brackets included with all LT series models for secure bulkhead or frame installation
- Corrosion-free polypropylene housing — impervious to salt water, exhaust condensate, and bilge environment; no rust, no galvanic interaction with metal components
- Wide size range — 40mm to 152mm — covers small auxiliary gensets through to large superyacht main propulsion engines
- Additional noise reduction — the gooseneck loop and volume provide a minor secondary muffling effect by trapping residual noise energy in the exhaust column
Typical Applications
- Any sailing yacht with an auxiliary diesel — the gooseneck is mandatory on all sailing vessels; the compact WLOCKLT series suits most sailing yacht auxiliaries (40–60mm), and the full LT series covers larger offshore yachts
- Generator set exhaust systems — gensets aboard motor yachts and superyachts sit well within the LT series’ power envelope regardless of the vessel’s overall size; the LT is the clean, standalone gooseneck option where the combined NLPG unit is not preferred
- Systems using the VETUS MF high-performance muffler — the MF has no integrated check valve or anti-syphon function, so a downstream LT gooseneck is required to complete the system
- Larger gensets and auxiliary engines requiring 76mm to 152mm exhaust hose — the full LT range covers substantial commercial generator sets and large auxiliary engines; the LT150 is appropriate for high-output gensets on larger vessels
Complete Your Wet Exhaust System
The gooseneck is fitted downstream of the waterlock and upstream of the transom connection. The top of the gooseneck must be at least 45 cm above the waterline. The exhaust hose section between the waterlock and the gooseneck high point must not exceed 300 cm in length, and the gooseneck high point must not be more than 150 cm above the underside of the waterlock.
Typical wet exhaust flow: Engine mixing elbow → Exhaust hose → Waterlock → Exhaust hose → Gooseneck → Exhaust hose → Transom connection
| Component | Role | Required? |
|---|---|---|
| Mixing elbow (injection bend) | Injects cooling water into exhaust gas at the manifold | Yes |
| Waterlock (LP / NLP / NLP3 / MG series) | Traps and separates injected water; primary noise reduction | Yes |
| Exhaust hose | Flexible wet-exhaust rated conduit between components | Yes |
| Gooseneck (LT / WLOCKLT series) | Anti-syphon loop — prevents syphoning on shutdown | Yes (this unit) |
| Transom connection | Hull exit fitting for exhaust discharge | Yes |
| Temperature alarm sender (XHSM) | Monitors exhaust temperature; triggers alarm on overheating | Recommended |
Installation & Compatibility Notes
- Minimum height 45 cm above waterline — the top of the gooseneck loop must be at least 45 cm above the loaded waterline; on a sailing yacht, account for heel and ensure the height is maintained at maximum heel angle
- Position as close to waterlock as possible — fitting the gooseneck directly above the waterlock (drawing 3/5) minimises the volume of water that drains back into the waterlock when the engine stops; fitting it at the transom (drawing 4/6) increases this return volume but may suit some layouts
- Max rise / max run — the highest point in the exhaust hose must not be more than 150 cm above the waterlock base; the hose run from the waterlock to the highest point must not exceed 300 cm
- Horizontal outlet standard — all WLOCKLT models have a horizontal outlet as standard; to convert to vertical (for through-deck exits), saw off section A and de-burr the edges; this modification is not available on LT models
- LT series mounting — use the supplied SS AISI 316 brackets; the gooseneck body must be adequately supported as the hose will contain water during operation
- Hose connections — use two stainless steel 12mm-wide hose clamps per connection; use water or soap to ease fitting — never grease or oil
- Use VETUS exhaust hose — reinforced, rated to 100°C, resistant to exhaust gas and oil; do not substitute with standard water hose
- Max continuous operating temperature: 70°C — fit a temperature alarm to protect against overheating
- Syphoning prevention at low injection point — if the engine’s water injection point is below or within 15 cm of the waterline, an air vent or anti-syphon valve must also be fitted in the cooling water hose between the engine block and the injection point