VETUS Anti-Siphon Air Vent (ASD Series)

$197.32

VETUS ASD anti-siphon air vent — prevents seawater syphoning back into the engine through the cooling water injection line when the engine stops. Available with (V) or without (H) integral VMQ anti-siphon valve. Standard 13–32mm adjustable connection (ASDH/ASDV) or 38mm fixed connection (ASD38H/ASD38V).

Add to Quote
SKU: N/A Category:

Description

📦 Dispatch & Availability: Standard Vetus exhaust items are available on back order and typically dispatch within 10 business days. Non-standard or larger items have a lead time of approximately 12 weeks from order.

The VETUS anti-siphon air vent (ASD series) prevents seawater from syphoning back through the exhaust system into the engine whenever the engine is stopped. Fitted in the cooling water supply line upstream of the water injection point, the air vent breaks the syphon by admitting a small amount of air when the engine stops — preventing the partial vacuum that would otherwise draw sea water backward through the injection elbow and into the engine. Two series are available: the standard ASDH/ASDV (13–32mm adjustable connection) and the ASD38H/ASD38V for larger 38mm systems. Within each series, the H variant uses a simple open tube (requiring a permanent vent pipe to hull) while the V variant adds an integral anti-siphon valve that opens on pressure drop and closes under positive flow, eliminating continuous water drip from the hull outlet during engine operation. Four models cover most wet exhaust and sanitary system applications aboard superyachts and motor yachts.

VETUS anti-siphon air vent — model selection guide

Model SKU Connection Ø Valve Vent Pipe Included Typical Use
ASDH ASDH 13–32mm (adjustable) No (open) Yes — 8×14mm, 4m Exhaust / toilets — where continuous hull drip during running is acceptable
ASDV ASDV 13–32mm (adjustable) Yes — VMQ No Exhaust / toilets — preferred; no drip during running; integral anti-siphon valve
ASD38H ASD38H 38mm No (open) Yes — 8×14mm, 4m Large exhaust systems; waste water discharge lines
ASD38V ASD38V 38mm Yes — VMQ No Large exhaust systems; waste water discharge lines — preferred with valve

ASDH/ASDV connection is 13mm native; saw down to 19mm, 25mm, or 32mm as required. ASD38H/ASD38V connect directly to 38mm hose. Valve sensitivity: 8 cm water column (VETUS installation manual 030426.01).

Key Features

  • Anti-siphon protection for wet exhaust systems — breaks the siphon that forms in the cooling water supply line when the engine stops, preventing seawater from tracking back through the injection elbow and into the engine cylinders
  • V variants — integral anti-siphon valve (VMQ) — opens under vacuum (siphon condition) to admit air and break the siphon; closes under positive flow during engine running; eliminates continuous water drip from the hull outlet that occurs with the open H variants
  • H variants — open tube type — simpler construction; vent pipe runs to a small hull outlet above the waterline; a small quantity of water continuously drips from the hull outlet while the engine runs (acceptable in some installations)
  • 360° rotatable vent pipe connection — the hose pillar for the vent pipe rotates fully to any angle, simplifying routing to the hull outlet
  • Adjustable connection size (ASDH/ASDV) — native connection 13mm; saw down to 19mm, 25mm, or 32mm as required to match the cooling water hose diameter; deburr after cutting
  • Polypropylene construction — corrosion-free; unaffected by salt water, engine coolant, and bilge environment
  • Mounting bracket available separately — MBSET02 for ASDH/ASDV; MBSET01 for ASD38H/ASD38V
  • Valve service kit available — ASDVS: 4 replacement VMQ valves and cleaning brush; replace valve every 2 years on V variants

Typical Applications

  • Generator set and auxiliary diesel cooling water supply lines — gensets aboard superyachts are often positioned low in the bilge, placing the cooling water injection point close to or below the waterline; the ASD is a routine fitting in these installations to prevent syphon-back on engine shutdown
  • VETUS NLPG muffler/gooseneck and LT gooseneck vent stub connection — both components include a purpose-built hose stub specifically for the ASD series; connecting an ASD ensures any trapped air in the gooseneck loop is vented correctly
  • Waste water discharge lines on tenders, sailing yachts, and smaller motor yachts — ASD38H/ASD38V fitted in the discharge pipe between pump and overboard outlet when the waste tank or pump is below the waterline
  • Below-waterline toilet discharge lines — any vessel where the holding tank or macerator pump sits below the waterline requires anti-siphon protection at the discharge line

Where It Fits in the Exhaust System

The ASD air vent is fitted in the cooling water supply line from the sea strainer/sea cock to the engine’s water injection point, not in the exhaust line itself. It must be positioned at least 40cm above the waterline (and no more than 2m above). In installations where the water injection point on the engine is below or within 15cm of the waterline, a siphon can form between the sea cock and the engine — the air vent breaks this siphon automatically on engine shutdown.

The ASD is also used on the integral vent stub of the VETUS NLPG muffler/gooseneck and LT gooseneck, where its role is to vent trapped air from the gooseneck loop rather than break a cooling water siphon.

Component Role Required?
Sea cock / sea strainer Raw water supply for engine cooling Yes
ASD Air Vent Anti-siphon protection in cooling water supply line Yes (this unit) — when injection point ≤15cm above WL
Water injection bend / mixing elbow Injects cooling water into exhaust gas stream Yes
Waterlock / muffler Separates and silences mixed wet exhaust Yes
Gooseneck (NLPG / LT series) Anti-siphon loop — vent stub for ASD connection Where fitted

Installation & Maintenance Notes

  • Mount 40cm–2m above waterline — the air vent must be at least 40cm above the waterline at all times; on sailboats install as close to amidships as possible to maintain this height when heeling
  • Hull outlet at least 15cm above waterline — the vent pipe hull outlet (H variants) must be above 15cm at all times including under heel
  • ASDH/ASDV connection adjustment — native size is 13mm; saw off sections to reach 19mm, 25mm, or 32mm; deburr thoroughly to avoid valve damage; use one SS hose clamp per connection
  • V variant valve maintenance — replace the VMQ valve every 2 years using the ASDVS service kit; use only Teflon spray as lubricant when fitting the new valve — no silicone oil, engine oil, or grease
  • H variant vent pipe — inspect the 8mm vent pipe regularly for blockages; a blocked vent pipe on an H variant will defeat the anti-siphon function entirely
  • Vent pipe routing — run the vent pipe continuously downhill from the air vent to the hull outlet; the hose pillar on the air vent is 360° rotatable to assist routing

Additional information

Model

ASDH — 13–32mm (no valve, vent pipe included), ASDV — 13–32mm (with valve, no vent pipe), ASD38H — 38mm (no valve, vent pipe included), ASD38V — 38mm (with valve, no vent pipe)

Material

Polypropylene body (PP) — VMQ anti-siphon valve (V variants)

Valve Sensitivity

8 cm water column (V variants)

Connection

ASDH/ASDV: 13mm native — adjustable to 19/25/32mm by cutting; ASD38H/ASD38V: 38mm fixed

Vent Pipe Stub

360° rotatable hose pillar — 8×14mm vent pipe to hull outlet

Min. Height Above Waterline

400mm (16") — 2000mm (6'7") maximum

Hull Outlet Min. Height

150mm (6") above waterline (including under heel)

Valve Service Kit

ASDVS — 4× VMQ valves and cleaning brush (V variants, replace every 2 years)

Mounting Bracket

MBSET02 (ASDH/ASDV) — MBSET01 (ASD38H/ASD38V) — sold separately

Brand

VETUS

Brand

Vetus