The FCI High Pressure Regulating Valve (83-0569) is the OEM manual needle valve used to control HP operating pressure on Aquamiser+, MaxQ+ and Atlas+ watermakers. By adjusting the restriction on the HP brine discharge line, the operator sets the RO membrane operating pressure and thereby the product water output quality (TDS) — closing the valve increases pressure and improves product quality; opening it reduces pressure. On Aquamiser+ it is the sole HP control valve. On MaxQ+ and Atlas+, it is the primary control valve on manual (non-APC) models and is also fitted to APC units as a mechanical backup alongside the automated HPCV (85-4790). The valve body is 316 stainless steel with 1/4″ FNPT connections and a large hand knob for field adjustment under operating pressure. Replace when the valve can no longer hold a stable set point or shows signs of seat wear or internal leakage. Special order through Y3 Marine.
Key Specifications
- OEM FCI manual HP regulating needle valve — 316SS body, angle pattern
- Connections: 1/4″ FNPT inlet and outlet
- Function: manual HP pressure adjustment for product water quality control
Compatible With
- Aquamiser+ (framed and modular) — primary HP control valve
- MaxQ+ (framed and modular) — primary valve on manual models; backup valve on APC models
- Atlas+ (framed and modular) — primary valve on manual models; backup valve on APC models