Genuine Raritan temperature & pressure (T&P) relief valve for the 1700 Series marine water heater. A safety-critical component that relieves on both over-temperature and over-pressure — the last line of defence if a thermostat sticks or the system over-pressurises. Available in 75 PSI and 100 PSI ratings with a ¾" NPT connection.
What it protects against
The T&P valve does two jobs at once. A temperature probe opens the valve if the stored water approaches ~99°C (210°F), venting before it can flash to steam; a spring relieves the tank if pressure exceeds the valve’s rating. Together they protect against tank rupture and scalding discharge. A stored-hot-water vessel must never run without a working, correctly-rated T&P valve.
Choosing 75 or 100 PSI
Match the valve to your system. The relief pressure must sit above the freshwater pump’s cut-out pressure but below the tank’s rating:
- 75 PSI (WH3) — standard fit on the 1700 Series; suits systems with a nominal working pressure up to ~50 PSI.
- 100 PSI (WH3A) — for higher-pressure systems running around ~60 PSI.
Never fit a higher-rated valve simply to stop an existing one weeping — that masks a real fault (see below) and reduces the tank’s protection.
Weeping valve? Check the accumulator first
A T&P valve that weeps a little every heating cycle is usually not faulty — it is relieving thermal expansion. As water heats it expands by 2–3%, and that extra volume has to go somewhere.
On a vessel the freshwater system’s pressure accumulator normally absorbs this expansion — its air cushion takes up the extra volume, exactly like a domestic expansion tank. Two things are essential for that to work:
- Never fit a non-return or isolating valve in the line between the water heater and the accumulator. Close that path and the calorifier becomes a sealed vessel — expansion is trapped and forced out through the T&P valve on every cycle. Any check valve used to stop hot water thermosiphoning into the cold lines must be positioned so the accumulator still communicates with the heated tank.
- Keep the accumulator healthy. A waterlogged accumulator, or one with the wrong air pre-charge, cannot absorb expansion and is a common real-world cause of a weeping T&P valve. Check the air charge before condemning the valve.
If the valve still weeps once the accumulator is confirmed healthy and the line to it is open, the valve itself is due for replacement.
When to replace
Replace the T&P valve if it:
- weeps or discharges during normal operation (once thermal expansion is ruled out)
- shows corrosion or mineral scaling around the seat
- has a seized or stiff test lever
- fails to reseat cleanly after operating
A relief valve must never be plugged, bypassed or swapped for a plain plug — that removes the tank’s only over-temperature and over-pressure protection.
Installation & discharge
Fit the valve in the heater’s designated relief port. Route the discharge line downhill to a safe, visible drain point, keep it full-size, and fit no valve or restriction anywhere in the discharge line. Operate the test lever at least annually and confirm the valve reseats cleanly.
⚠ Australian Compliance
Marine water heaters on vessels in Australian waters require a temperature & pressure relief valve certified to AS/NZS 1271. CE-marked or international valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm the correct rating and compliance with your marine surveyor before commissioning.