TDS Probe

$255.04

Genuine FCI OEM replacement TDS probe for Aqualite, Aquamiser+, MaxQ+, Atlas+, and Neptune+ watermakers. 5-wire, 4.6 m sensor cable with BNC connector. Monitors product water quality and triggers the quality valve. In stock at Y3 Marine.

2 in stock

Add to Quote

Description

The FCI TDS Probe (SKU 50-4862) is the genuine OEM replacement conductivity sensor for the product water quality circuit on FCI Aqualite, Aquamiser+, MaxQ+, Atlas+, and Neptune+ watermakers. The probe sits inline in the product water line and continuously monitors TDS (Total Dissolved Solids) — the control system reads the probe signal and opens the quality valve to pass water to tank when TDS is below the setpoint, or closes it to divert product water to drain when TDS is too high. A faulty, fouled, or damaged probe will cause incorrect quality readings: the system may shut down on a TDS fault despite the membrane producing good water, or — more critically — may pass poor-quality water to tank if the probe fails open. The probe features a 5-wire lead with a 4.6 m (15′) sensor cable and BNC connector. Stocked at Y3 Marine for immediate despatch.

Key Features

  • Genuine FCI OEM replacement TDS probe — SKU 50-4862, 5-wire leads, 4.6 m (15′) sensor cable, BNC connector
  • Monitors product water TDS continuously and signals the control system to open or close the quality valve
  • A fouled probe will cause false TDS faults and unnecessary system shutdowns — clean the probe before condemning it
  • A failed or damaged probe risks passing off-spec product water to tank — a critical failure mode on a potable water system
  • Compatible with all FCI systems: Aqualite, Aquamiser+, MaxQ+, Atlas+, Neptune+
  • Stocked by Y3 Marine, Australia’s authorised FCI dealer — available for immediate despatch

Typical Superyacht Applications

  • Replacement of a fouled or damaged TDS probe causing persistent TDS faults or incorrect quality readings
  • Scheduled probe replacement during a watermaker overhaul or control system service
  • Commissioning spare held onboard for immediate swap-out if probe failure occurs on passage

Installation & Compatibility Notes

  • Compatible with: FCI Aqualite, Aquamiser+, MaxQ+, Atlas+, Neptune+ (all models)
  • Clean probe regularly — mineral deposits on the sensor element cause false high-TDS readings; a soft brush and dilute acid solution will remove scale
  • BNC connector — plug directly into the FCI control board probe port
  • Refer to the applicable FCI User Manual for probe installation location and wiring details

Brand

FCI Watermakers