Switch – Low Pressure

OEM FCI 316 SS low pressure switch for Aqualite and Aquamiser+ watermakers. 1 PSI (6.9 kPa) trip point, normally open — closes to confirm adequate LP feed pressure and opens to trigger shutdown if pressure drops. Part of LP gauge assembly (Aqualite 93-8437). Special order.

Add to Quote
SKU: 56-0283 Categories: ,

Description

The FCI Low Pressure Switch (56-0283) is the OEM 316 stainless steel pressure switch that monitors feed water pressure on Aqualite and Aquamiser+ watermakers. With a 1 PSI (6.9 kPa) trip point and normally open contact configuration, it confirms the LP pump has built sufficient feed pressure before and during operation — closing the circuit above 1 PSI and opening it (triggering a system shutdown) if pressure drops below that threshold. Wired to the AQ3 control board (COM = pin 1 black, N.O. = pin 3 red), it is part of the LP gauge assembly on both platforms. A failed switch is a common cause of false low-pressure fault shutdowns when feed supply and pre-filter condition are otherwise healthy. Special order through Y3 Marine.

Key Features

  • OEM FCI LP pressure switch — 316 stainless steel body for seawater service
  • Trip point: 1 PSI (6.9 kPa) — normally open, closes above 1 PSI to confirm adequate feed pressure
  • System shuts down when circuit opens (pressure drops below 1 PSI)
  • Wired to AQ3 control board: COM pin 1 (black), N.O. pin 3 (red)
  • Part of LP gauge assembly: Aqualite (93-8437), Aquamiser+ (LP switch/gauge assembly)
  • Male thread connection — mounts into LP circuit PVC tee
  • Replace when generating false low-pressure faults with confirmed healthy feed supply and clean pre-filter

Typical Superyacht Applications

  • LP feed pressure monitoring and fault protection on FCI Aqualite and Aquamiser+ watermakers
  • Direct replacement during LP circuit service or fault diagnosis of low-pressure shutdowns
  • Part of a full LP gauge assembly rebuild

Installation & Compatibility Notes

  • Compatible with: Aqualite (framed), Aquamiser+ (framed)
  • Wiring connects to AQ3 control board — refer to wiring schematic in the relevant user manual
  • Do not confuse with the HP switch (56-0282, 1025 PSI trip point, N.C.) — different pressure rating, contact type, and circuit location
  • Companion LP gauge differs by model: Aqualite uses 78-5088 (15 PSI); Aquamiser+ uses 78-1869 (60 PSI)

⚠️ Special Order — This part is not stocked in Sydney. Lead times apply. Contact Y3 Marine to confirm availability and arrange supply.

Brand

FCI Watermakers