Description
Genuine SEPAR replacement filter element for the SWK-2000/5/50 (300 LPH). The /5/50 uses the extended 50 mm element — taller than the standard /5 element, with more media area for greater water/dirt holding and longer service intervals. It provides the final polishing stage (stage 5) of the 5-stage separation process, after the centrifugal stages have already removed the bulk of water and heavy particulate — so it stays clean far longer than a conventional inline primary filter and can be backflushed up to 5 times before replacement.
Element Options
| Micron Rating | Part Number | Description |
|---|---|---|
| 10 micron — fine | 00510/50 | Fine filtration for contaminated fuel or injector-sensitive engines; shorter service interval. |
| 30 micron — standard | 00530/50 | General-purpose marine diesel; fitted as standard; best service life in normal operation. |
| 60 micron — stainless steel | 00560/50S | Heavy-duty stainless element; longest interval; for clean, well-managed fuel tanks. |
Elements ship with TPE seals as standard; HNBR seals (for biodiesel and aggressive fuels) are available to order.
Important — /5 and /5/50 elements are not interchangeable
The /5/50 element is taller than the standard /5 element. Fit only the /50 series (00510/50, 00530/50, 00560/50S) to a /5/50 unit — the standard /5 element will not seal or filter correctly in the taller /5/50 bowl.
Backflush Procedure
SEPAR elements can be backflushed up to 5 times before replacement, extending service life well beyond a conventional inline filter element.
- Close the upstream ball valve to shut off fuel supply to the filter.
- Open the bleed screw on the filter lid one full turn.
- Let fuel backflush through the element for ~30 seconds, or until the flow from the bleed screw runs clean.
- Close the bleed screw and reopen the upstream ball valve.
- Prime the fuel system before restarting the engine.
If backflushing no longer restores flow, the element has reached the end of its life — replace it. Do not run the engine with a blocked element.
Element Replacement
- Shut off fuel supply before opening the filter (upstream ball valve, or the tank outlet cock).
- In a duplex system, switch the changeover lever to the standby unit first; never open an active head under fuel flow.
- Remove the bowl with a container ready for residual fuel; fit the new element, seating it against the head O-ring.
- Inspect the bowl gasket / O-ring and replace if compressed, cracked or deformed.
- Refit the bowl hand-tight only — no tools; over-tightening damages the bowl or thread.
- Prime and check for leaks before leaving unattended.