Description
The SEPAR SWK-2000/18 is a 1,080 LPH two-stage diesel fuel filter and water separator — the mid-large model in the SWK-2000 range, suited to large generator sets and the main engines of mid-size yachts with lift-pump flow up to about 830 LPH. Made in Germany by Willibrord Lösing Filtertechnik, it uses a patented multi-stage centrifugal process, independently certified by TÜV to 99.9% water separation at maximum flow (SAE J1839). The non-corroding aluminium-alloy housing and stainless hardware suit the vibration, salt air and thermal cycling of a marine engine room. A 30-micron cleanable element is fitted as standard (P30); 10-micron and 60-micron stainless alternatives are available. Single-unit ports are 1 1/16″-12 SAE straight O-ring (22 mm pipe); duplex units ship with #12 male JIC flare adapters.
Choose your configuration
Build the /18 with three choices — single or duplex, bowl type, and whether a water-in-fuel sensor is fitted:
- Type — Single, or Duplex (twin filters on a lever changeover, so one keeps the engine running while the other is serviced).
- Bowl — Clear bowl (see water at a glance) · Clear bowl + heat shield (adds the metal shield so the clear bowl is fire-safe for engine-room installation under AMSA/NSCV fire-safety provisions) · Metal bowl (inherently fire-safe and the most robust).
- Water sensor — add a water-in-fuel alarm contact (W01) that signals the vessel’s panel when water collects in the bowl, or leave it off.
Separ codes — U: duplex / changeover · D: clear bowl with heat shield · M: metal bowl · W01: water-in-fuel sensor · P30: 30-micron element · C01: 1 1/16″-12 SAE O-ring ports. An automatic-changeover duplex (“A”), plus heater kits (cold-climate anti-waxing), vacuum/restriction gauge, 60-micron stainless element and RINA class-approval builds, are available to order.
Clear bowl, metal bowl or heat shield — which to choose
The clear polycarbonate bowl lets the crew see water and debris collecting at a glance. In an enclosed engine space a bare plastic bowl can be a fire risk, so the clear-bowl + heat shield build adds a fire-safe metal shield — you keep the visual check while meeting engine-room fire / ignition-protection requirements under AMSA/NSCV. The metal bowl is inherently fire-safe and the most robust, trading away the visual check. A water sensor can be added to any bowl to signal the alarm panel.
Key Features
- 99.9% water separation at maximum flow — TÜV certified (SAE J1839) — strips free water from condensation, poor deliveries and tank ingress before it can reach the injection system.
- Five-stage centrifugal separation + filtration — water and heavy particulate are spun out mechanically before the element, so the element only polishes what remains — far longer element life than a plain inline primary filter.
- Backflushable element — cleanable up to ~5 times before replacement — cleaned in place via the bleed-screw procedure.
- Duplex changeover — no engine shutdown to service — switch to the standby unit, service the active one, switch back; auto-changeover (“A”) available to order.
- fire-safe metal heat shield on the clear-bowl (D) builds — keeps the visual water check while meeting engine-room fire / ignition-protection rules.
- Aluminium-alloy body, stainless hardware — non-corroding; diesel, biodiesel blends and marine distillate compatible.
Where It Fits in Your Fuel System
The SWK-2000 is a primary, suction-side fuel filter — fitted between the tank and the engine-mounted lift pump. The lift pump draws through it at all loads, so the SEPAR’s maximum flow must comfortably exceed the lift-pump flow. A duplex install is the recommended choice for any single-main-engine vessel or continuously-running generator — element maintenance never means stopping the engine.
Full Range — Model Selection Guide
| Model | Max Flow | Lift Pump Up To | Typical Marine Application |
|---|---|---|---|
| SWK-2000/5 | 300 LPH | ~230 LPH | Small diesels, tenders, outboards |
| SWK-2000/5/50 | 300 LPH | ~230 LPH | Same flow, extended element — longer service |
| SWK-2000/10 | 600 LPH | ~450 LPH | Gensets 20–80 kW, tender main engines |
| SWK-2000/18 | 1,080 LPH | ~830 LPH | Large gensets, main engines on smaller yachts |
| SWK-2000/40 | 2,400 LPH | ~1,900 LPH | Commercial engines, large main propulsion |
| SWK-2000/130 | 7,800 LPH | ~6,100 LPH | Very large commercial and industrial diesels |
Size to the engine lift-pump flow rate, not the burn rate. Contact Y3 Marine if you’re unsure of your lift-pump flow.
Installation Notes
- Suction side only — fit between the fuel tank and the lift pump, not downstream of it.
- Mounting height — at roughly the lift-pump height; if the tank top sits above the filter, fit a full-flow ball valve upstream so fuel can be shut off for element service without draining the tank.
- Orientation — mount vertically, bowl down and accessible from below for water draining and element service.
- Prime after install or element change — prime with the lift pump or the optional SEPAR hand-priming pump before starting.
- Element — 30-micron standard (01830); 10-micron (01810) or 60-micron stainless (01860S) as required; drain water at each service and backflush before replacing.
- Water alarm (W01 sensor option) — if the sensor is fitted, test the alarm at commissioning by introducing a little water to the bowl and confirming it triggers before draining.