Rule SuperSwitch Float Switch

A bilge float switch is the automatic brain of the bilge system. A non-automatic (manual) bilge pump only runs when someone throws a switch — fine until water starts coming in while the boat is unattended. Wired in, the float switch senses the rising bilge level and starts the pump by itself, then shuts it off once the water drops, so the vessel is protected around the clock whether anyone is aboard or not.

The Rule SuperSwitch is the go-to float switch for heavy-duty bilge pump installations and is required for the Rule 14,000 LPH and 15,140 LPH pumps. Heavy-duty double-insulated blocked wiring and a wide, free-action float give superior buoyancy and performance in challenging bilge environments. Removable snap-on base for easy fitting, cleaning and servicing.

Suits any brand of submersible bilge pump (12V / 24V / 32V) with a maximum draw of 20 A. Base footprint 66 × 45 mm; overall 135 mm L × 54 mm W. 5-year limited warranty.

Test it every month

A float switch is a safety-critical part that spends its whole life sitting in a dark, wet, dirty bilge — exactly where things seize, foul and corrode. A stuck switch gives no warning: it simply fails to fire on the one day it’s needed. At least once a month, lift the float by hand (or pour water into the bilge) and confirm the pump cuts in, then cuts out again as the float drops back. Check that the hinge is free of hair, oil film and debris, that the wiring and connections are clean, tight and dry, and that the base is still mounted level and secure. Treat a sluggish, noisy or intermittent switch as a failed one and replace it — a float switch costs a fraction of the pump it protects, and far less than the boat it can save.

Dealer notes

  • Low-profile 20 A switch — fits shallow bilges where a caged float won’t.
  • Ideal partner for the LoPro and standard submersibles; required for the 14,000 / 15,140 LPH pumps.
  • Wide free-action float — keep the hinge and float path clear of debris.
  • Mount on a level surface and test the float action monthly.

Fitting & service guide — float switch / panel

Mounting & wiring

  1. De-power first — switch off and pull the fuse before wiring; confirm dead.
  2. Mount the float switch beside the pump and slightly higher, on a solid base, with clear swing room so the float can’t foul hoses, wiring or bilge frames.
  3. Wire the switch into the pump’s positive feed; for automatic operation take a permanent, fused feed so the pump still works with the main panel off. On a 3-way panel, wire manual / off / auto.
  4. Use marine-grade crimps and heat-shrink and keep all joints above the waterline.

Test

  • Raise the water (or lift the float) and confirm the pump cuts in and out cleanly at the right level.
  • Always back an automatic pump with an independent high-water alarm — the switch that runs the pump should never be the only thing telling you the bilge is filling.
  • Test monthly as routine — a bilge switch that fails quietly is only found when it is needed.