Description
Rule’s standard-range submersible bilge pumps deliver reliable bilge management for vessels from small runabouts to large yachts. The Next Generation DA Series features ignition-protected, water/air-cooled motors, moisture-tight wiring, stainless steel shaft, and snap-on strainer bases for easy cleaning and servicing. All models require a Rule float switch for automatic operation.
The compact round-base housing suits tight bilge installations. Available in 360, 500, 800, and 4,160 LPH capacities in both 12V and 24V (except 1,360 LPH which is 12V only). Backed by Rule’s 3-year limited warranty.
Specifications by model
| Model | Flow (open) | Voltage | Current draw |
|---|---|---|---|
| 1,360 LPH (RWB800) | 23 LPM | 12V | 2.3 A |
| 1,890 LPH (RWB801) | 31 LPM | 12V | 1.6 A |
| 1,890 LPH (RWB802) | 31 LPM | 24V | 0.8 A |
| 3,030 LPH (RWB803) | 50 LPM | 12V | 3.0 A |
| 3,030 LPH (RWB804) | 50 LPM | 24V | 1.5 A |
| 4,160 LPH (RWB805) | 69 LPM | 12V | 3.8 A |
| 4,160 LPH (RWB806) | 69 LPM | 24V | 2.0 A |
Nuisance water, MARPOL & oily-water discharge
These electric pumps are nuisance-water pumps. Their job is to keep the bilge dry in normal service — clearing the everyday accumulation of rainwater, deck washdown, spray, condensation and shaft-gland or packing drips. They are not an emergency dewatering system for a holed or flooding hull; that role belongs to a manual bilge pump and to fixed emergency pumps sized to the vessel.
Because a bilge pump discharges whatever is in the bilge overboard, oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm oil, and never discharge in a port or a designated special area. Smaller craft without a separator must hold oily bilge water and land it ashore — it must not be pumped over the side. A visible diesel or oil sheen in the bilge means overboard discharge is illegal. Keep machinery-space bilges clean and oil-free, and route the bilge to a holding tank or separator where contamination is possible — this matters most with automatic pumps, which can discharge unattended.
Test it monthly
A bilge pump that fails quietly is only discovered when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: lift the float or trigger the sensor, confirm the pump actually runs and moves water, and check that the strainer is clear, the non-return/check valve seats, and the discharge line runs freely with no air lock. Confirm any automatic model cuts in and out on its own. Keep a spare strainer base and service kit aboard so a blocked intake can be put right on the spot.
Dealer notes
- Non-automatic — needs a float switch or a panel’s AUTO leg to run on its own; on its own it’s manual-only.
- Size by flow & hull. 360 for small tenders up to 1100 for a cabin bilge; step up to the High-Capacity range above that.
- Snap-on strainer base lifts the pump for cleaning without touching the plumbing — keep a spare base on the shelf.
- Fuse and cable to the plate and avoid voltage drop on long runs — it kills flow.