Description
Rule’s high-capacity bilge pump range is built to the same commercial standards trusted by Yachtsmen and fishermen worldwide. All models feature double-insulated, dual water/air-cooled motors, moisture-tight wiring, Teflon seals, stainless steel shaft, anti-airlock design, and ignition-protected construction — won’t create a spark.
The 1500 and 7,570 LPH models share the same compact 152 mm H × 108 mm W housing with a 28 mm (1⅛”) hose outlet and snap-on strainer base. The 3700 and 15,140 LPH extra-heavy-duty models step up to a larger 184–197 mm housing, 38 mm or 50 mm hose outlets, and extra-heavy-duty motors capable of delivering up to 252 litres per minute. All include stainless mounting screws and carry Rule’s 3-year limited warranty. Requires a Rule float switch (RWB19 or RWB98 for 3700/15,140 LPH) to operate automatically.
Specifications by model
| Capacity | Flow (open) | Housing size | Hose outlet | Notes |
|---|---|---|---|---|
| 5,680 LPH | 94 LPM | 152 mm H × 108 mm W | 28 mm (1⅛”) | 4.8 A @ 12V / 2.3 A @ 24V |
| 7,570 LPH | 126 LPM | 152 mm H × 108 mm W | 28 mm (1⅛”) | 8.4 A @ 12V / 4.1 A @ 24V |
| 14,000 LPH | 233 LPM | 184 mm H × 124 mm W | 38 mm (1½”) | 15.5 A @ 12V / 6.9 A @ 24V — use RWB19/RWB98 float switch |
| 15,140 LPH | 252 LPM | 197 mm H × 124 mm W | 50 mm (2″) | 15.5 A @ 12V / 6.9 A @ 24V — use RWB19/RWB98 float switch |
Nuisance water, MARPOL & oily-water discharge
These electric pumps are nuisance-water pumps. Their job is to keep the bilge dry in normal service — clearing the everyday accumulation of rainwater, deck washdown, spray, condensation and shaft-gland or packing drips. They are not an emergency dewatering system for a holed or flooding hull; that role belongs to a manual bilge pump and to fixed emergency pumps sized to the vessel.
Because a bilge pump discharges whatever is in the bilge overboard, oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm oil, and never discharge in a port or a designated special area. Smaller craft without a separator must hold oily bilge water and land it ashore — it must not be pumped over the side. A visible diesel or oil sheen in the bilge means overboard discharge is illegal. Keep machinery-space bilges clean and oil-free, and route the bilge to a holding tank or separator where contamination is possible — this matters most with automatic pumps, which can discharge unattended.
Test it monthly
A bilge pump that fails quietly is only discovered when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: lift the float or trigger the sensor, confirm the pump actually runs and moves water, and check that the strainer is clear, the non-return/check valve seats, and the discharge line runs freely with no air lock. Confirm any automatic model cuts in and out on its own. Keep a spare strainer base and service kit aboard so a blocked intake can be put right on the spot.
Dealer notes
- Serious volume — 1500 to 4000 for large bilges, wells and emergency dewatering.
- Non-automatic — pair with a heavy-duty float switch or 3-way panel.
- Wire heavy. High current draw — size the cable and fuse to the plate or you’ll lose flow to voltage drop.
- Not a substitute for a survey-rated emergency pump on commercial vessels.