Description
Rule-A-Matic Plus Float Switch
A bilge float switch is the automatic brain of the bilge system. A non-automatic (manual) bilge pump only runs when someone throws a switch — fine until water starts coming in while the boat is unattended. Wired in, the float switch senses the rising bilge level and starts the pump by itself, then shuts it off once the water drops, so the vessel is protected around the clock whether anyone is aboard or not.
The Rule-A-Matic Plus is the first choice of boatbuilders worldwide. Its strong fully integrated cover protects against debris jamming the switch, while the built-in manual test feature lets you verify operation at any time. 14-gauge highly abrasion-resistant blocked wiring exits the top of the switch to minimise wear.
Suits all Rule non-automatic DC bilge pumps (12V / 24V / 32V) with a maximum draw of 20 A. Removable snap-on base for easy fitting, cleaning and servicing. Base 135 × 63 mm; height 72 mm. 2-year limited warranty.
Test it every month
A float switch is a safety-critical part that spends its whole life sitting in a dark, wet, dirty bilge — exactly where things seize, foul and corrode. A stuck switch gives no warning: it simply fails to fire on the one day it’s needed. At least once a month, lift the float by hand (or pour water into the bilge) and confirm the pump cuts in, then cuts out again as the float drops back. Check that the hinge is free of hair, oil film and debris, that the wiring and connections are clean, tight and dry, and that the base is still mounted level and secure. Treat a sluggish, noisy or intermittent switch as a failed one and replace it — a float switch costs a fraction of the pump it protects, and far less than the boat it can save.
Dealer notes
- 20 A rated — drives the bigger Rule pumps a 14 A switch can’t.
- Caged float resists fouling from bilge debris — still check it’s free each month.
- Built-in manual test makes the monthly check quick — use it.
- Wire in parallel with a 3-way panel for AUTO plus manual override.
Fitting & service guide — float switch / panel
Mounting & wiring
- De-power first — switch off and pull the fuse before wiring; confirm dead.
- Mount the float switch beside the pump and slightly higher, on a solid base, with clear swing room so the float can’t foul hoses, wiring or bilge frames.
- Wire the switch into the pump’s positive feed; for automatic operation take a permanent, fused feed so the pump still works with the main panel off. On a 3-way panel, wire manual / off / auto.
- Use marine-grade crimps and heat-shrink and keep all joints above the waterline.
Test
- Raise the water (or lift the float) and confirm the pump cuts in and out cleanly at the right level.
- Always back an automatic pump with an independent high-water alarm — the switch that runs the pump should never be the only thing telling you the bilge is filling.
- Test monthly as routine — a bilge switch that fails quietly is only found when it is needed.
Genuine Rule (Xylem). Supplied by Y3 Marine.