Racor Turbine 1000 Series — Diesel Fuel Filter / Water Separator (Single, Duplex & Triplex)

Price range: $990.55 through $5,335.70

The Parker Racor Turbine 1000 Series is the largest-capacity Turbine platform — 681 LPH (180 GPH) per head — for gensets in the 50–120 kW range and main propulsion engines on motor yachts and commercial vessels. Three configurations: single 1000MA; duplex 751000MAX (6-way changeover valve, 1,363 LPH); and triplex 791000MAV (three individually-valved heads, 2,044 LPH) for high-output main engines, prime-power gensets and high-flow fuel transfer or polishing — where both maximum capacity and service-on-the-run matter. Its 3-stage turbine process removes 99% of free water and particulate into a clear or full-metal bowl. Built to ISO 10088 with ABS type-approval, it supports AMSA / NSCV fuel-system compliance on Australian commercial vessels. 30, 10 or 2 micron Aquabloc elements.

Add to Quote
SKU: N/A Category:

Description

📦 Dispatch & Availability: Most items are available on back order and typically dispatch within 10 business days. Filters not held in stock at the distributor can have a lead time of approximately 6–8 weeks from order.

The Racor Turbine 1000 Series is the largest-capacity Turbine platform — 681 LPH per head — for generator sets in the 50–120 kW range and main propulsion engines on motor yachts and commercial vessels. Available in three configurations: single 1000MA; duplex 751000MAX (two heads, 6-way changeover valve, 1,363 LPH); and triplex 791000MAV (three individually-valved heads, 2,044 LPH). The duplex adds a standby head with a 6-way changeover valve, so the active filter can be serviced without stopping the engine. The triplex goes further — three individually-valved heads give the range’s highest flow (2,044 LPH) while letting any one head be isolated and serviced on the run as the other two carry the load. The triplex is the configuration for high-output main propulsion diesels, prime and continuous-power generator sets, and high-flow fuel transfer or polishing on larger commercial vessels and superyachts. The 3-stage Turbine process delivers 99% water removal into a visible sump. Optional 12V/24V electric primer kit retrofittable. UL-listed, ABS type-approved, ISO 10088 and ASTM FS1201 certified.

Model & Options

Config Max Flow Bowl / Micron SKU
Single (1000MA) 681 LPH Clear / 30 micron (standard marine) 1000MA30
Single (1000MA) 681 LPH Clear / 10 micron 1000MA10
Single (1000MA) 681 LPH Full metal / 30 micron (fire-safe metal) 1000MAM30
Single (1000MA) 681 LPH Full metal / 10 micron 1000MAM10
Duplex (751000MAX) 1,363 LPH (681/head) Clear / 30 micron (standard marine) 751000MAX30
Duplex (751000MAX) 1,363 LPH (681/head) Clear / 10 micron 751000MAX10
Duplex (751000MAX) 1,363 LPH (681/head) Full metal / 30 micron (fire-safe metal) 751000MAXM30
Triplex (791000MAV) 2,044 LPH (681/head) Clear / 30 micron (standard marine) 791000MAV30
Triplex (791000MAV) 2,044 LPH (681/head) Clear / 10 micron 791000MAV10
Triplex (791000MAV) 2,044 LPH (681/head) Full metal / 30 micron (fire-safe metal) 791000MAVM30

Ports: 7/8″-14 SAE (single/duplex, metric on request); 3/4″-14 NPT (triplex). Element: 2020 Series (one per head). Duplex uses a 6-way changeover valve; triplex has an individual isolation valve per head. Single 4.5 kg (metal bowl 5.0 kg) / Duplex 13.6 kg / Triplex 23.6 kg. Allow 25.4 cm overhead clearance per head. Optional primer kit RKP1912 (12V) / RKP1924 (24V).

3-Stage Turbine Separation Process

Stage 1 — Turbine centrifuge: Fuel enters and is spun by internal turbine vanes, generating centrifugal force that throws large water droplets and heavy particulate to the outer wall of the bowl where they settle. Stage 2 — Aquabloc coalescence: Smaller water droplets contact the Aquabloc filter media where they coalesce into larger droplets and fall to the water sump below the element. Stage 3 — Aquabloc filtration: The Aquabloc element provides final particulate polishing at the rated micron. The result is 99% water removal efficiency into the clear sump, visible at a glance without opening the filter.

Replacement Elements — 1000 Series

The 1000 Series uses colour-coded 2020 Series Aquabloc elements, rated by micron: Red = 30 micron (primary filtration, most common marine application); Blue = 10 micron (secondary/finer filtration, more frequent service intervals); Brown = 2 micron (final polishing, for common-rail and high-pressure injection systems with tight injector tolerances). Always order elements with the “-OR” suffix to include the O-ring set. In a duplex or triplex unit, each head takes one element — order elements in matching sets.

Bowl Options

The standard configuration (no M suffix) uses a clear polycarbonate bowl behind a stainless-steel shield, letting crew read the water sump level at a glance without opening the filter. The full metal bowl (M suffix) trades that visibility for fire integrity — a metal bowl resists heat and flame where a polycarbonate bowl can soften or fail. On Australian commercial vessels, AMSA’s DCV framework and the NSCV require fuel-system components in machinery spaces to minimise fire risk, so the metal bowl is the safer specification where the filter sits in or near an enclosed engine space. Both bowls accept the same replacement elements and water-in-fuel probes. If you are unsure which bowl your survey requires, contact Y3 Marine — we will advise for your vessel and operating category.

Model Selection Guide — Turbine Series

Model Config Max Flow Element Typical Application
500MA Single 227 LPH 2010 Small diesels, chase boats, auxiliary engines to ~20 kW
900MA Single 341 LPH 2040 Gensets 20–50 kW, chase-boat main engines
75900MAX Duplex 681 LPH (341 LPH/head) 2040 Continuous-service gensets 20–50 kW
1000MA Single 681 LPH 2020 Gensets 50–120 kW, main engines on smaller yachts
751000MAX Duplex 1,363 LPH (681 LPH/head) 2020 Continuous-service large gensets and main engines
791000MAV Triplex (valved) 2,044 LPH (681 LPH/head) 2020 Large commercial engines and prime power

Size to the engine lift pump flow rate, not the burn rate. A duplex or triplex configuration is recommended for any single-engine vessel or generator set that cannot be taken offline for element servicing.

Installation Notes

  • Suction-side installation — fit between the fuel tank and the engine-mounted lift pump; the Racor Turbine is a primary suction-side filter and must not be installed downstream of the lift pump under positive pressure
  • Mounting height — mount as low as practical, ideally with the filter head at or below the fuel level in the tank so it primes by gravity and runs at low vacuum. Locate it between the bottom of the fuel tank and the fuel-pump inlet.
  • Suction lift — if the filter must sit above the fuel level, keep static lift to about 1.5 m (5 ft) maximum and total inlet restriction under 4 inHg (~135 mbar); excess lift promotes cavitation, fuel degassing and hard priming.
  • Tank above the filter — fit an inlet shut-off valve so the element can be changed without siphoning the tank, aiding clean, contained servicing.
  • Maximum allowable working pressure — 1.7 bar (25 PSI); do not exceed; suction-side installation keeps operating pressure well below this limit in normal service
  • Overhead clearance — allow clearance above each head for element removal: 12.7 cm (500 Series), 19.1 cm (900 Series), 25.4 cm (1000 Series); the bowl drains downward — allow bowl-length clearance below
  • Mounting orientation — vertical, bowl down; the head can be rotated to align inlet/outlet with the fuel lines before tightening
  • Duplex / triplex changeover — switch to the standby head before opening the active head for service; the engine keeps running throughout
  • Water sensor — connect the WIF probe (if fitted) to the vessel’s alarm panel; test at commissioning by deliberately running a small volume of water through the filter and confirming the alarm activates
  • Prime after service — prime the fuel system using the engine lift pump or the optional electric primer pump kit (RKP1912 12V / RKP1924 24V) before restarting the engine after element replacement
  • Emergency bypass — each element has a punch-out tab for a get-home run on unfiltered fuel (replace ASAP); on a duplex or triplex, switch to the standby head first — it keeps full filtration.

Additional information

Model

Racor Turbine 1000MA/MAM (single) · 751000MAX (duplex) · 791000MAV (triplex)

Configuration

Single, Duplex, Triplex

Max Flow Rate

681 LPH (180 GPH) per head — duplex 1,363 LPH · triplex 2,044 LPH

Bowl

Clear bowl, Full metal bowl

Micron

30 micron (Red), 10 micron (Blue)

Element Series

2020 Series — 2 / 10 / 30 micron Aquabloc

Filtration / Separation Media

Aquabloc® water-repelling, 3-stage turbine (centrifuge, coalescence, filtration)

Water Removal Efficiency

99%

Port Size

7/8"-14 UNF SAE (single/duplex; 22 mm × 1.5 metric on request) · 3/4"-14 NPT (triplex)

Max Allowable Working Pressure

1.7 bar (25 PSI)

Clean Pressure Drop

0.03 bar (0.43 PSI)

Dimensions (H × W × D)

Single 55.9 (metal 54.5) × 15.2 × 17.8 cm · Duplex 55.9 × 45.7 × 27.9 cm · Triplex 55.9 × 54.6 × 30.0 cm

Weight (dry)

Single 4.5 kg (clear) / 5.0 kg (metal) · Duplex ~13.6 kg · Triplex ~23.6 kg

Service Clearance

25.4 cm above · 5.1 cm below for element removal & bowl drain

Max Fuel Temperature

88 °C (190 °F)

Ambient Temperature Range

-40 °C to +124 °C

Changeover / Isolation

Duplex: 6-way changeover valve · Triplex: individual isolation valve per head

Mounting

Vertical, bowl down — single clamp bracket (duplex/triplex on common manifold)

Installation

Suction side — between fuel tank and engine lift pump

Optional Water Sensor

RK21069 (clear bowl) / RK23191 (metal bowl) WIF probe — requires detection module

Optional Primer Pump

RKP1912 (12 V) / RKP1924 (24 V) — retrofittable

Approvals

UL-listed · ABS type-approved · ISO 10088 · ASTM FS1201

Country of Origin

Made in USA (Parker Hannifin — Racor Division)

Brand

Parker Racor