Description
📦 Dispatch & Availability: Most items are available on back order and typically dispatch within 10 business days. Filters not held in stock at the distributor can have a lead time of approximately 6–8 weeks from order.
The Racor Turbine 1000 Series is the largest-capacity Turbine platform — 681 LPH per head — for generator sets in the 50–120 kW range and main propulsion engines on motor yachts and commercial vessels. Available in three configurations: single 1000MA; duplex 751000MAX (two heads, 6-way changeover valve, 1,363 LPH); and triplex 791000MAV (three individually-valved heads, 2,044 LPH). The duplex adds a standby head with a 6-way changeover valve, so the active filter can be serviced without stopping the engine. The triplex goes further — three individually-valved heads give the range’s highest flow (2,044 LPH) while letting any one head be isolated and serviced on the run as the other two carry the load. The triplex is the configuration for high-output main propulsion diesels, prime and continuous-power generator sets, and high-flow fuel transfer or polishing on larger commercial vessels and superyachts. The 3-stage Turbine process delivers 99% water removal into a visible sump. Optional 12V/24V electric primer kit retrofittable. UL-listed, ABS type-approved, ISO 10088 and ASTM FS1201 certified.
Model & Options
| Config | Max Flow | Bowl / Micron | SKU |
|---|---|---|---|
| Single (1000MA) | 681 LPH | Clear / 30 micron (standard marine) | 1000MA30 |
| Single (1000MA) | 681 LPH | Clear / 10 micron | 1000MA10 |
| Single (1000MA) | 681 LPH | Full metal / 30 micron (fire-safe metal) | 1000MAM30 |
| Single (1000MA) | 681 LPH | Full metal / 10 micron | 1000MAM10 |
| Duplex (751000MAX) | 1,363 LPH (681/head) | Clear / 30 micron (standard marine) | 751000MAX30 |
| Duplex (751000MAX) | 1,363 LPH (681/head) | Clear / 10 micron | 751000MAX10 |
| Duplex (751000MAX) | 1,363 LPH (681/head) | Full metal / 30 micron (fire-safe metal) | 751000MAXM30 |
| Triplex (791000MAV) | 2,044 LPH (681/head) | Clear / 30 micron (standard marine) | 791000MAV30 |
| Triplex (791000MAV) | 2,044 LPH (681/head) | Clear / 10 micron | 791000MAV10 |
| Triplex (791000MAV) | 2,044 LPH (681/head) | Full metal / 30 micron (fire-safe metal) | 791000MAVM30 |
Ports: 7/8″-14 SAE (single/duplex, metric on request); 3/4″-14 NPT (triplex). Element: 2020 Series (one per head). Duplex uses a 6-way changeover valve; triplex has an individual isolation valve per head. Single 4.5 kg (metal bowl 5.0 kg) / Duplex 13.6 kg / Triplex 23.6 kg. Allow 25.4 cm overhead clearance per head. Optional primer kit RKP1912 (12V) / RKP1924 (24V).
3-Stage Turbine Separation Process
Stage 1 — Turbine centrifuge: Fuel enters and is spun by internal turbine vanes, generating centrifugal force that throws large water droplets and heavy particulate to the outer wall of the bowl where they settle. Stage 2 — Aquabloc coalescence: Smaller water droplets contact the Aquabloc filter media where they coalesce into larger droplets and fall to the water sump below the element. Stage 3 — Aquabloc filtration: The Aquabloc element provides final particulate polishing at the rated micron. The result is 99% water removal efficiency into the clear sump, visible at a glance without opening the filter.
Replacement Elements — 1000 Series
The 1000 Series uses colour-coded 2020 Series Aquabloc elements, rated by micron: Red = 30 micron (primary filtration, most common marine application); Blue = 10 micron (secondary/finer filtration, more frequent service intervals); Brown = 2 micron (final polishing, for common-rail and high-pressure injection systems with tight injector tolerances). Always order elements with the “-OR” suffix to include the O-ring set. In a duplex or triplex unit, each head takes one element — order elements in matching sets.
Bowl Options
The standard configuration (no M suffix) uses a clear polycarbonate bowl behind a stainless-steel shield, letting crew read the water sump level at a glance without opening the filter. The full metal bowl (M suffix) trades that visibility for fire integrity — a metal bowl resists heat and flame where a polycarbonate bowl can soften or fail. On Australian commercial vessels, AMSA’s DCV framework and the NSCV require fuel-system components in machinery spaces to minimise fire risk, so the metal bowl is the safer specification where the filter sits in or near an enclosed engine space. Both bowls accept the same replacement elements and water-in-fuel probes. If you are unsure which bowl your survey requires, contact Y3 Marine — we will advise for your vessel and operating category.
Model Selection Guide — Turbine Series
| Model | Config | Max Flow | Element | Typical Application |
|---|---|---|---|---|
| 500MA | Single | 227 LPH | 2010 | Small diesels, chase boats, auxiliary engines to ~20 kW |
| 900MA | Single | 341 LPH | 2040 | Gensets 20–50 kW, chase-boat main engines |
| 75900MAX | Duplex | 681 LPH (341 LPH/head) | 2040 | Continuous-service gensets 20–50 kW |
| 1000MA | Single | 681 LPH | 2020 | Gensets 50–120 kW, main engines on smaller yachts |
| 751000MAX | Duplex | 1,363 LPH (681 LPH/head) | 2020 | Continuous-service large gensets and main engines |
| 791000MAV | Triplex (valved) | 2,044 LPH (681 LPH/head) | 2020 | Large commercial engines and prime power |
Size to the engine lift pump flow rate, not the burn rate. A duplex or triplex configuration is recommended for any single-engine vessel or generator set that cannot be taken offline for element servicing.
Installation Notes
- Suction-side installation — fit between the fuel tank and the engine-mounted lift pump; the Racor Turbine is a primary suction-side filter and must not be installed downstream of the lift pump under positive pressure
- Mounting height — mount as low as practical, ideally with the filter head at or below the fuel level in the tank so it primes by gravity and runs at low vacuum. Locate it between the bottom of the fuel tank and the fuel-pump inlet.
- Suction lift — if the filter must sit above the fuel level, keep static lift to about 1.5 m (5 ft) maximum and total inlet restriction under 4 inHg (~135 mbar); excess lift promotes cavitation, fuel degassing and hard priming.
- Tank above the filter — fit an inlet shut-off valve so the element can be changed without siphoning the tank, aiding clean, contained servicing.
- Maximum allowable working pressure — 1.7 bar (25 PSI); do not exceed; suction-side installation keeps operating pressure well below this limit in normal service
- Overhead clearance — allow clearance above each head for element removal: 12.7 cm (500 Series), 19.1 cm (900 Series), 25.4 cm (1000 Series); the bowl drains downward — allow bowl-length clearance below
- Mounting orientation — vertical, bowl down; the head can be rotated to align inlet/outlet with the fuel lines before tightening
- Duplex / triplex changeover — switch to the standby head before opening the active head for service; the engine keeps running throughout
- Water sensor — connect the WIF probe (if fitted) to the vessel’s alarm panel; test at commissioning by deliberately running a small volume of water through the filter and confirming the alarm activates
- Prime after service — prime the fuel system using the engine lift pump or the optional electric primer pump kit (RKP1912 12V / RKP1924 24V) before restarting the engine after element replacement
- Emergency bypass — each element has a punch-out tab for a get-home run on unfiltered fuel (replace ASAP); on a duplex or triplex, switch to the standby head first — it keeps full filtration.