Description
📦 Dispatch & Availability: Most items are available on back order and typically dispatch within 10 business days. Items not held in stock at the distributor can have a lead time of approximately 6–8 weeks from order.
The Parker Racor RVFS Series is a high-capacity, two-stage fuel filter / water separator vessel for diesel fuel dispensing, bulk fuel transfer, fuel polishing and large-engine supply. Fabricated entirely in 304 stainless steel with Viton® O-rings, it strips emulsified free water and solid contamination from diesel, fuel oils and other hydrocarbon streams — protecting injection systems, extending element life downstream and keeping critical plant running clean.
How it works — two-stage coalesce then separate
The RVFS runs two elements in series: a coalescer (HOCP) first, then a separator (HSP). Fuel enters and passes through the coalescer, where fine, emulsified water droplets are merged (coalesced) into large droplets and heavy solids are captured. Those droplets fall into the internal water sump between the two stages; the hydrophobic separator stage then blocks any remaining water while letting clean, dry fuel pass to the outlet. A complete fuel filter/water separator therefore needs one coalescer plus one separator. The same vessel can alternatively run particulate prefilter, water-absorbing or clay-bag elements where the duty calls for it.
Where it fits — commercial, supply & large-yacht fuel systems
The RVFS is a high-capacity, code-stamped vessel built for professional fuel handling. It suits commercial and supply vessels as much as large yachts — wherever diesel is moved, dispensed, stored or polished in volume and fuel cleanliness is operationally critical.
- Commercial & supply/support vessels — OSVs, tugs, ferries, pilot, patrol and workboats under AMSA survey, where a dirty-fuel stoppage is a safety and commercial event. Two-stage coalesce-and-separate protects main-engine and genset injection at 25–75 GPM.
- Bulk fuel transfer & bunkering — strip free water and solids as fuel moves between storage, day and service tanks, or is taken on at the dock.
- Fuel polishing at scale — large tanks that sit between voyages gather condensation, sludge and diesel bug; the RVFS runs as a dedicated polishing loop to keep the whole bunker clean.
- Large-engine & standby-power supply — main-engine feed and emergency/standby generators that must have clean, dry fuel ready on demand.
- Large yachts & superyacht fuel systems — bunker conditioning and transfer where fuel volumes are well beyond a compact spin-on or Turbine primary.
- Shore-side & barge fuel points — dispensing and depot filtration for marinas, fuel barges and support facilities.
For smaller craft — tenders, chase boats and motoryachts — a compact Racor Turbine or the P510MAM polisher is the right tool; the RVFS is the step up for commercial-scale flow and duty.
Specifications
| Specification | RVFS-1 | RVFS-2 | RVFS-3 |
|---|---|---|---|
| Max flow (diesel) | 94 L/min (25 GPM) | 189 L/min (50 GPM) | 283 L/min (75 GPM) |
| Inlet / Outlet ports | 2″ NPT | 2″ NPT | 2″ NPT |
| Vent / Relief ports | 3/4″ NPT | 3/4″ NPT | 3/4″ NPT |
| Water-gauge ports | 1/2″ NPT | 1/2″ NPT | 1/2″ NPT |
| Diff-gauge ports | 1/8″ NPT | 1/8″ NPT | 1/8″ NPT |
| Pressure / temp | 250 PSI @ 250°F (17 bar @ 121°C) — ASME code stamped | ||
| Clean pressure drop | 2 PSID (0.14 bar) | ||
| Change-out ΔP | 15 PSID (1.0 bar) | ||
| Height | 89.7 cm | 126.5 cm | 162.1 cm |
| Width × Depth | 34.3 × 33.5 cm | ||
| Dry weight | 45 kg | 52 kg | 59 kg |
| Overhead service clearance | 40.6 cm | 81.3 cm | 119.4 cm |
Flow rating by element type
Rated flow depends on the element fitted — size the vessel to the element type for your duty, not just the vessel body:
| Element type | RVFS-1 | RVFS-2 | RVFS-3 |
|---|---|---|---|
| Coalescer / separator | 95 L/min | 190 L/min | 285 L/min |
| Prefilter (particulate) | 250 L/min | 500 L/min | 1000 L/min |
| Monitor | 110 L/min | 220 L/min | 330 L/min |
Sizing & biodiesel
The flow ratings above are for standard diesel. For biodiesel blends above B20, Racor recommends over-sizing the application by 50% to preserve coalescer performance (biodiesel is more difficult to de-water). Always size on the element type and the real transfer/dispense flow, and allow margin so the vessel runs below its rating for long element life and low restriction.
Replacement elements (order separately)
A fuel filter/water separator = 1 × HOCP coalescer + 1 × HSP separator, matched to the vessel size and the micron you need (1 / 5 / 10 / 25 µm):
| Vessel | Coalescer (HOCP) | Separator (HSP) |
|---|---|---|
| RVFS-1 | 1µm HOCP-15801 · 5µm 15805 · 10µm 15810 · 25µm 15825 | 1µm HSP-15401 · 5µm 15405 · 10µm 15410 · 25µm 15425 |
| RVFS-2 | 5µm HOCP-30805 · 10µm 30810 · 25µm 30825 | 1µm HSP-30401 · 5µm 30405 · 10µm 30410 · 25µm 30425 |
| RVFS-3 | 5µm HOCP-44805 · 10µm 44810 · 25µm 44825 | 1µm HSP-44401 · 5µm 44405 · 10µm 44410 · 25µm 44425 |
How to order the vessel
Vessel part numbers follow RVFS-[size]-MO-SS — e.g. RVFS-1-MO-SS. Choose the size (1 / 2 / 3); each vessel is supplied as a Minimal Options (MO) build — a differential-pressure gauge, one water sight glass, a manual air vent and a manual water drain, with the remaining ports plugged.
Build out from there with the fittings your installation needs — auto air eliminator, pressure relief valve, auto/manual water drains, stainless water-level gauge and sample points — from the RVFS Vessel Accessories & Fittings listing. Ask Y3 Marine to build the exact configuration for your site.
Installation & practical notes
- Plumbing — 2″ NPT inlet and outlet; pipe the vessel into the transfer/dispense line or a dedicated polishing loop on the day tank. Support the vessel independently — a full RVFS-3 is heavy (59 kg dry, more in service).
- Overhead service clearance is critical — you withdraw the elements vertically from the top, so leave 40.6 cm (RVFS-1), 81.3 cm (RVFS-2) or 119.4 cm (RVFS-3) clear above the lid. Design it in before mounting.
- Differential-pressure gauge — change the elements on restriction, not the calendar: a clean vessel reads ~2 PSID; change out at 15 PSID. The gauge takes the guesswork out of service intervals.
- Water management — check the sight glass(es) and drain the sump via the manual (or optional auto) water drain before water backs up to the separator stage. Sample probes let you pull fuel for testing without breaking into the line.
- Venting — use the 3/4″ NPT vent/relief ports; bleed air with the manual air vent (or fit the auto air eliminator) after an element change so the vessel primes cleanly.
- Materials — 304 SS body and Viton® seals suit ULSD and biodiesel blends; no internal/external painting to fail. ASME-stamped as standard (250 PSI / 17 bar); PED/CE (10 barg) construction available for European-code sites.
Pump & system integration — the RVFS is a filter vessel, not a pump
The RVFS has no integral pump. Unlike the Racor P Series module or the P510MAM polisher — both of which carry their own electric pump — the RVFS is a passive two-stage filtration vessel that must be driven by a separate pump plumbed into the fuel system. Getting that pump and its plumbing right is as important as the vessel itself: the coalescer/separator will only perform if the fuel is delivered at the correct flow, pressure and cleanliness. The guidance below is written so you can specify the pump correctly the first time.
Where the RVFS sits — push-through vs pull-through
Because the vessel is rated to 250 PSI (17 bar), it is happiest on the discharge (pressure) side of the pump — the pump draws clean from the tank and pushes fuel through the RVFS to the outlet, day tank or dispenser. This keeps the pump’s suction free of filter restriction and avoids starving it as the elements load. A pull-through arrangement (pump downstream, RVFS on the suction side) is possible but places the vessel’s restriction in series with the pump’s suction lift, which erodes the available suction head as the elements dirty — only use it with a short, low static lift and a vacuum gauge to watch it.
Pump type — use positive displacement
For transfer, dispensing and polishing duty, use a positive-displacement (PD) pump — gear, vane, lobe or screw (diaphragm for smaller flows). A PD pump is self-priming, delivers a near-constant flow regardless of the rising back-pressure as the elements load, and develops the head needed to push through a dirty filter. A centrifugal pump is a poor choice here: its flow collapses as differential pressure climbs, it will not reliably self-prime, and its output would fall away exactly as the elements approach change-out. Choose the pump’s wetted materials and seals for diesel/biodiesel compatibility (Viton®-class elastomers, as used in the vessel).
The single most important rule: do not over-flow the coalescer
A coalescer is flow-velocity sensitive. Its rated flow (94 / 189 / 283 L/min for RVFS-1 / 2 / 3, and different again for prefilter or monitor elements — see the flow-by-element table above) is the maximum for effective water coalescing, not a target to beat. Push fuel through faster than the element is rated and the higher media velocity shears and re-entrains the coalesced water droplets before they can drop into the sump — water removal efficiency falls off a cliff even though the vessel is ‘working’. Therefore the pump must deliver at or below the element’s rated flow. If your available pump is larger than the vessel rating, control the flow with a recirculation/bypass loop back to tank or a variable-speed (VFD) drive so the vessel never sees more than its rated flow. Under-flowing is fine (longer element life, better separation); over-flowing defeats the purpose of a coalescer/separator.
Sizing the pump — flow rate
Size the flow to the element type fitted, and to the duty:
- Transfer / dispensing — match the pump to the coalescer/separator rating (94 / 189 / 283 L/min) so a full-load transfer still coalesces cleanly.
- Fuel polishing — size on tank turnover, not engine burn. A common target is to circulate the tank contents several times per polishing cycle; pick a flow that turns the tank over at the interval you want, then confirm it is within the coalescer rating for the chosen vessel size (step up a vessel if not).
Sizing the pump — head / pressure
The pump must develop enough head to move the rated flow through the system in its dirtiest (change-out) state, not just when clean. Sum the components:
- Static lift from the tank draw point to the vessel/discharge.
- Pipe and fitting friction at the design flow (2″ NPT ports keep vessel-side losses low, but long runs, elbows and valves add up).
- Vessel restriction — ~2 PSID (0.14 bar) clean, rising to the 15 PSID (1.0 bar) change-out point as the elements load. Size the pump on the 15 PSID figure so flow holds all the way to service, then use the differential-pressure gauge to change out at 15 PSID.
- Downstream restriction — dispensing nozzle, flow meter, day-tank fill height, back-pressure valves.
Choosing the pump on the clean condition is the classic error — flow then sags as the elements dirty and the coalescer velocity/quality window shifts. Design for the loaded case.
Protect the pump — relief / bypass is mandatory
A positive-displacement pump will deadhead and over-pressure the system if a downstream valve is shut or the filter blocks completely. You must fit relief protection: either a pump-integral relief valve or the vessel’s pressure-relief-valve accessory (part 71330-150, 150 PSIG), piped back to tank. This is a safety item, not an option — it caps system pressure below the vessel’s 250 PSI rating and protects hoses, seals and the pump.
Suction conditions & cavitation (NPSH)
Keep the pump’s available NPSH above its required NPSH. Diesel has a low vapour pressure, but a long or high suction lift — made worse if the filter is on the suction side and loading up — can drop suction pressure toward the fuel’s vapour point and cause cavitation (noise, flow loss, pump wear), especially with warm fuel or biodiesel. Mitigate by mounting the pump close to and not far above the tank draw, keeping suction pipe generously sized and short, and — the simplest fix — putting the RVFS on the discharge side so its restriction never robs the suction. Fit the auto air eliminator (71679) or use the manual air vent to clear air after element changes so the vessel primes and the pump doesn’t draw air.
Fuel-polishing loop layout
On a polishing loop, draw from a low point at one end of the tank and return to the opposite end to sweep the whole tank and avoid short-circuiting clean fuel straight back to the pickup. Run at a low, steady flow within the coalescer rating — gentle circulation coalesces far better than a fast blast — on a timer or continuously for standby-power tanks that sit between runs. Draw low enough to lift the water and sludge that collect at the tank bottom, which is exactly what the RVFS is there to remove.
Monitoring, control & materials
Fit the differential-pressure gauge (72059) to time element changes on restriction, a water-level sight glass/gauge to watch the sump, and consider a flow meter to confirm the pump is holding the design flow. Sample probes let you draw fuel for testing without breaking the line. Ensure the whole circuit — pump, hose, seals and the 304 SS vessel — is compatible with ULSD and your biodiesel blend, and that the installation is properly bonded/earthed.
Y3 Marine can specify the complete package — the matched transfer or polishing pump, relief and control accessories, and the correct RVFS vessel and element set — sized to your flow, fuel and duty. Talk to us before you buy the pump.
Parker Racor.