Racor P Series Fuel Conditioning Module — Diesel Filter with Electric Pump

$1,175.90

Racor P Series diesel fuel conditioning module — filter/water separator with integral 12 V electric lift pump, 10 PSI regulator, water sensor and thermostatic PTC pre-heater (now standard). P3/P4/P5, 114–189 LPH, 10 micron. Diesel only. Install outside engine room (ABYC). Parker Racor.

Add to Quote
SKU: N/A Category:

Description

📦 Dispatch & Availability: Most items are available on back order and typically dispatch within 10 business days. Items not held in stock at the distributor can have a lead time of approximately 6–8 weeks from order.

The Racor P Series fuel conditioning module combines a diesel fuel filter/water separator with an integral 12 V DC roller-cell electric lift pump, pressure regulator, water sensor and a thermostatically-controlled PTC pre-heater in one self-contained unit. Installed on the vacuum (suction) side, it draws fuel from the tank, strips water and contaminant, warms the fuel against cold-weather waxing, and delivers clean fuel at a regulated 10 PSI to the engine — removing the need for a separate mechanical lift pump. Parker now supplies the range as a single configuration per size with the pre-heater fitted as standard. Available in P3 (114 LPH), P4 (151 LPH) and P5 (189 LPH). Diesel only — not for petrol. ABYC requires installation outside the engine room.

Models

Model SKU Max Flow Replacement Element
P3 P3210NH 114 LPH (30 GPH) R58060
P4 P4210NH 151 LPH (40 GPH) R58095
P5 P5210NH 189 LPH (50 GPH) R58039

Each module ships with a 10-micron Aquabloc® element, integral PTC pre-heater, water sensor and 10 PSI regulator as standard. Parker has discontinued the separate no-heater (“N”) builds and the 2-micron elements — the pre-heater is now integral to every module. Not for continuous-duty fuel transfer or polishing; the roller-cell pump is rated for intermittent lift-pump duty only.

Where the P Series fits

The P Series earns its keep wherever you need to deliver clean, primed, regulated fuel to a small-to-mid diesel without leaning on the engine’s own mechanical lift pump. Because it bundles the filter/water separator, electric lift pump, regulator, water sensor and pre-heater into one unit that mounts outside the engine room, it suits installations that value simple plumbing and reliable electric priming over engine-room-grade primary filtration.

  • Large tenders & chase boats — hard-run, refuelled from bowsers of variable quality, often with awkward tank-to-engine runs and crew who aren’t engineers. Push-button electric priming after a filter change or run-dry is the standout feature.
  • Sportfishers & fast day boats — a single compact conditioning unit for an inboard diesel, mounted clear of the engine space.
  • Small gensets — a genset wants clean, primed, regulated fuel and rarely has a robust lift arrangement of its own; the P Series is purpose-built as a conditioning module for exactly this.
  • Repowers & retrofits — where a new engine needs lift assistance and plumbing in a separate mechanical pump is difficult, the module is the lift pump.
  • Long-lift installations — where the tank sits well below or far from the engine and suction restriction is high, the integral electric pump does the lifting.
  • Small commercial, pilot & patrol craft — reliability and one-box simplicity where downtime is costly.

Where to use something else

The P Series is a supply-conditioning unit — not an engine-room primary or a polishing rig:

  • Main propulsion on larger vessels — fit a Racor Turbine (500 / 900 / 1000, single or duplex/triplex) in the engine room for engine-room-rated primary filtration with change-on-the-run capability.
  • Fuel polishing or transfer — the roller-cell pump is rated for intermittent lift-pump duty, not continuous running. For polishing, use a dedicated continuous-duty system such as CJC offline filtration.
  • Petrol — diesel only; the pre-heater is not for petrol.

Key Features

  • Filter + pump + regulator + heater in one unit — a single mounting location outside the engine room; only fuel, electrical and return connections to make.
  • Integral 12 V electric lift pump — roller-cell pump draws from the tank without a separate mechanical lift pump; 10 PSI regulated output.
  • Thermostatic PTC pre-heater — standard — prevents diesel waxing/gelling in cold operation; self-regulating (diesel only, not for petrol).
  • Water-in-fuel sensor included as standard — fitted to every P3/P4/P5 module at no extra cost (not an add-on option); wires to the vessel alarm panel or a dash warning light to flag water in the bowl the moment it collects. For a ready-made helm alarm, pair it with the Racor Water-in-Fuel Detection Kit (under-dash warning light, optional buzzer).

Specifications

Spec P3 P4 P5
Max flow rate 114 LPH (30 GPH) 151 LPH (40 GPH) 189 LPH (50 GPH)
Max outlet pressure 10 PSI (0.7 bar) 10 PSI (0.7 bar) 10 PSI (0.7 bar)
Micron 10 µm Aquabloc® 10 µm Aquabloc® 10 µm Aquabloc®
Pre-heater PTC thermostatic (std) PTC thermostatic (std) PTC thermostatic (std)
Port size 3/8"-18 NPT 3/8"-18 NPT 3/8"-18 NPT
Voltage 12 V DC 12 V DC 12 V DC
Element R58060 R58095 R58039
Weight (dry) — 1.7 kg 1.9 kg
Dimensions (H×D×W) — 22.9 × 13.2 × 12.2 cm 29.2 × 13.2 × 12.2 cm

Installation Notes

  • Install outside the engine room — ABYC requires the P Series in a non-engine-room location; mount in a dry, accessible space with short fuel runs to and from the tank.
  • Suction-side only — the electric pump draws from the tank; do not install downstream of a pressurised fuel supply.
  • Electrical — wire the 12 V pump to a fused, switched circuit that runs only with the engine; do not wire to a continuous-live circuit.
  • Prime before starting — run the pump briefly after an element change to fill the housing.

Additional information

Size

P3 — 114 LPH, P4 — 151 LPH, P5 — 189 LPH

Micron

10 µm · Blue (standard)

Heater

Integral thermostatic PTC pre-heater — standard

Type

Diesel fuel conditioning module — filter/water separator + electric pump + regulator (vacuum side)

Priming Pump

Integral 12 V roller-cell electric pump — on-demand repriming

Pressure Regulator

10 PSI (0.7 bar) — standard

Water Sensor

Standard

Ports

3/8"-18 NPT

Voltage

12 V DC

Fuel Type

Diesel only — NOT for petrol (heater is not for petrol use)

Install Note

ABYC: mount outside the engine room

Brand

Parker Racor