Description
📦 Dispatch & Availability: Most items are available on back order and typically dispatch within 10 business days. Items not held in stock at the distributor can have a lead time of approximately 6–8 weeks from order.
The Racor P Series fuel conditioning module combines a diesel fuel filter/water separator with an integral 12 V DC roller-cell electric lift pump, pressure regulator, water sensor and a thermostatically-controlled PTC pre-heater in one self-contained unit. Installed on the vacuum (suction) side, it draws fuel from the tank, strips water and contaminant, warms the fuel against cold-weather waxing, and delivers clean fuel at a regulated 10 PSI to the engine — removing the need for a separate mechanical lift pump. Parker now supplies the range as a single configuration per size with the pre-heater fitted as standard. Available in P3 (114 LPH), P4 (151 LPH) and P5 (189 LPH). Diesel only — not for petrol. ABYC requires installation outside the engine room.
Models
| Model | SKU | Max Flow | Replacement Element |
|---|---|---|---|
| P3 | P3210NH | 114 LPH (30 GPH) | R58060 |
| P4 | P4210NH | 151 LPH (40 GPH) | R58095 |
| P5 | P5210NH | 189 LPH (50 GPH) | R58039 |
Each module ships with a 10-micron Aquabloc® element, integral PTC pre-heater, water sensor and 10 PSI regulator as standard. Parker has discontinued the separate no-heater (“N”) builds and the 2-micron elements — the pre-heater is now integral to every module. Not for continuous-duty fuel transfer or polishing; the roller-cell pump is rated for intermittent lift-pump duty only.
Where the P Series fits
The P Series earns its keep wherever you need to deliver clean, primed, regulated fuel to a small-to-mid diesel without leaning on the engine’s own mechanical lift pump. Because it bundles the filter/water separator, electric lift pump, regulator, water sensor and pre-heater into one unit that mounts outside the engine room, it suits installations that value simple plumbing and reliable electric priming over engine-room-grade primary filtration.
- Large tenders & chase boats — hard-run, refuelled from bowsers of variable quality, often with awkward tank-to-engine runs and crew who aren’t engineers. Push-button electric priming after a filter change or run-dry is the standout feature.
- Sportfishers & fast day boats — a single compact conditioning unit for an inboard diesel, mounted clear of the engine space.
- Small gensets — a genset wants clean, primed, regulated fuel and rarely has a robust lift arrangement of its own; the P Series is purpose-built as a conditioning module for exactly this.
- Repowers & retrofits — where a new engine needs lift assistance and plumbing in a separate mechanical pump is difficult, the module is the lift pump.
- Long-lift installations — where the tank sits well below or far from the engine and suction restriction is high, the integral electric pump does the lifting.
- Small commercial, pilot & patrol craft — reliability and one-box simplicity where downtime is costly.
Where to use something else
The P Series is a supply-conditioning unit — not an engine-room primary or a polishing rig:
- Main propulsion on larger vessels — fit a Racor Turbine (500 / 900 / 1000, single or duplex/triplex) in the engine room for engine-room-rated primary filtration with change-on-the-run capability.
- Fuel polishing or transfer — the roller-cell pump is rated for intermittent lift-pump duty, not continuous running. For polishing, use a dedicated continuous-duty system such as CJC offline filtration.
- Petrol — diesel only; the pre-heater is not for petrol.
Key Features
- Filter + pump + regulator + heater in one unit — a single mounting location outside the engine room; only fuel, electrical and return connections to make.
- Integral 12 V electric lift pump — roller-cell pump draws from the tank without a separate mechanical lift pump; 10 PSI regulated output.
- Thermostatic PTC pre-heater — standard — prevents diesel waxing/gelling in cold operation; self-regulating (diesel only, not for petrol).
- Water-in-fuel sensor included as standard — fitted to every P3/P4/P5 module at no extra cost (not an add-on option); wires to the vessel alarm panel or a dash warning light to flag water in the bowl the moment it collects. For a ready-made helm alarm, pair it with the Racor Water-in-Fuel Detection Kit (under-dash warning light, optional buzzer).
Specifications
| Spec | P3 | P4 | P5 |
|---|---|---|---|
| Max flow rate | 114 LPH (30 GPH) | 151 LPH (40 GPH) | 189 LPH (50 GPH) |
| Max outlet pressure | 10 PSI (0.7 bar) | 10 PSI (0.7 bar) | 10 PSI (0.7 bar) |
| Micron | 10 µm Aquabloc® | 10 µm Aquabloc® | 10 µm Aquabloc® |
| Pre-heater | PTC thermostatic (std) | PTC thermostatic (std) | PTC thermostatic (std) |
| Port size | 3/8"-18 NPT | 3/8"-18 NPT | 3/8"-18 NPT |
| Voltage | 12 V DC | 12 V DC | 12 V DC |
| Element | R58060 | R58095 | R58039 |
| Weight (dry) | — | 1.7 kg | 1.9 kg |
| Dimensions (H×D×W) | — | 22.9 × 13.2 × 12.2 cm | 29.2 × 13.2 × 12.2 cm |
Installation Notes
- Install outside the engine room — ABYC requires the P Series in a non-engine-room location; mount in a dry, accessible space with short fuel runs to and from the tank.
- Suction-side only — the electric pump draws from the tank; do not install downstream of a pressurised fuel supply.
- Electrical — wire the 12 V pump to a fused, switched circuit that runs only with the engine; do not wire to a continuous-live circuit.
- Prime before starting — run the pump briefly after an element change to fill the housing.