Quick Nautic Boiler BX 16L

The Quick Nautic Boiler BX 16L is a compact 16-litre dual-source marine water heater for tenders, day boats and small cruisers. It recovers free hot water from the engine’s cooling circuit underway and heats on 240 V shore power or generator, via an Argon-welded stainless tank, AISI 316 heat exchanger and Incoloy® element (500 / 600 / 1200 W). Thermoformed casing, adjustable bi-thermostat and combined safety valve — a full-featured calorifier in a small footprint.

Add to Quote
SKU: QUICK-BX-16L Categories: ,

Description

The Quick Nautic Boiler BX 16L is a slim-line version of the BX range — optimised for small vessels and single-berth installation spaces where a compact 16-litre capacity is sufficient. Thermoformed casing, stainless steel tank, and full dual-source heating capability.

Key features of the Quick Nautic Boiler BX 16L

  • Compact 16 L capacity — ideal for day boats, tenders and small cruisers
  • Thermoformed plastic outer casing
  • Stainless steel tank, Argon-welded
  • 316 SS heat exchanger
  • Incoloy® electric element (500 W, 600 W or 1200 W)
  • Adjustable bi-thermostat
  • Combined safety relief and non-return valve
  • Stainless mounting brackets

How it works — dual heating

The BX 16L heats two ways, automatically: the 316 stainless heat exchanger recovers waste heat from the engine’s cooling circuit for free hot water underway, and the Incoloy® element heats the tank on 240 V shore power or generator when the engine is cold. Whichever source is available does the work — no switching required.

Temperature, Legionella & usable capacity

The adjustable bi-thermostat sets the storage temperature. Store the water hot (60°C+) to suppress Legionella, then rely on a thermostatic mixing valve to temper delivery to a safe ≤50°C at the outlets. A hotter store also stretches a compact 16 L tank further — each litre of stored water blends into more litres of warm water at the tap.

Maintenance & genuine spares

Keep to genuine Quick parts for the wear items:

Scaling up — multiple heaters in parallel or series

On larger vessels where a single tank can’t meet demand, calorifiers are installed in multiples:

  • Parallel — two or more tanks share a common cold feed and combined hot outlet, storing and delivering hot water at the same time. This roughly multiplies both the stored volume and the peak simultaneous draw — the usual choice for several bathrooms drawing at once. For it to balance, the tanks must be equally matched (same capacity and rating) and set to the same temperature, with equal-length or reverse-return pipework so they draw and refill evenly. Each tank keeps its own relief valve and expansion provision.
  • Series — the hot outlet of one tank feeds the cold inlet of the next, so the first pre-heats and the second brings the water to final temperature. The two tanks needn’t match: you can run the first (pre-heat) tank cooler and the second (final) tank hotter, and the second stage can even be a smaller tank, since it only has to lift already-warmed water the last step. The classic use is an engine heat-exchanger tank pre-heating water that then passes to an electric tank for final heating — recovering free engine heat while guaranteeing delivery temperature alongside. Series extends continuous draw but does not add simultaneous flow the way parallel does.

Match the layout to the load: parallel for peak simultaneous demand, series for pre-heat and sustained draw. Size and configure to the vessel’s hot-water demand, and confirm with your surveyor on commercial and passenger vessels.

Hot water circulation loops

On a vessel with long pipe runs, hot water can take a while to reach distant heads and galleys — you run the tap and wait, wasting time and precious fresh water. A hot water circulation loop fixes this: a circulation pump continuously moves hot water from the calorifier around the system and back via a return line, so hot water is available instantly at every outlet. It also keeps the whole system at temperature with no dead legs — good practice for Legionella control. Use a bronze or stainless circulation pump rated for potable hot water — such as the Calpeda NCE energy-saving circulation pump — controlled by a timer or thermostat to save energy, and insulate the loop.

Design & installation — we can help

Y3 Marine can design and install your complete hot-water system — sizing the calorifier(s), circulation loop, tempering and safety valves, and pump selection to suit your vessel and demand. Contact us to discuss your installation.

⚠ Australian Installation Requirements

All marine water heaters installed aboard vessels in Australian waters must comply with the following requirements. Failure to comply may constitute a vessel safety deficiency under the National Standard for Commercial Vessels (NSCV C5A).

  • Temperature & Pressure Relief Valve (T&PRV): A T&PRV rated and certified to AS/NZS 1271 must be fitted to this unit. CE-marked or international relief valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm compliance with your marine surveyor before commissioning.
  • Thermostatic Mixing Valve (TMV): A thermostatic mixing valve must be installed at all hot water outlets. The TMV limits delivery temperature to prevent scalding and is required as a safety measure on all commercial and passenger vessels.

Compliance is the responsibility of the installer and vessel operator. Y3 Marine recommends installation by a licensed marine plumber or qualified engineer.

Additional information

Brand

Quick

Range

Nautic Boiler BX (16L)

Capacity

16 L

Tank Material

Stainless steel (Argon-welded)

Heat Exchanger

AISI 316 stainless steel

Heating Element

Incoloy® — 500W / 600W / 1200W (230V)

Casing

Thermoformed plastic

Safety Valve

Combined safety relief & non-return

Thermostat

Adjustable bi-thermostat

Voltage

230V / 50Hz

Working Pressure

5 bar

Water Connections

½" BSP

Mounting

Stainless steel brackets

Warranty

3 years