Quick Nautic Boiler BK3

The Quick Nautic Boiler BK3 is the highest-output model in the Nautic Boiler range — a 200-litre, electric-only superyacht calorifier with no engine heat exchanger. It heats purely by electricity via a twin Incoloy® element rated at 4000 W or 8000 W for fast recovery, ideal for large yachts with ample generator or inverter capacity. Argon-welded 316 stainless tank, integrated temperature control panel and adjustable levelling feet. Note the heavy supply current — size the circuits and AC source accordingly.

Add to Quote
SKU: QUICK-BK3 Categories: ,

Description

The Quick Nautic Boiler BK3 is the highest-output model in the Nautic Boiler range — a 200-litre electric-only superyacht water heater (no engine heat exchanger), heated by a twin Incoloy® element rated for 4000 W or 8000 W. Built for charter and large private yachts with multiple bathrooms and high simultaneous hot water demand. PVC and composite casing over a 316 SS Argon-welded tank. Includes temperature control panel and adjustable levelling feet.

Key features of the Quick Nautic Boiler BK3

  • 200 L capacity
  • Twin Incoloy® electric element (4000 W or 8000 W total)
  • 316 AISI stainless steel tank, Argon-welded
  • Electric-only — no engine heat exchanger
  • Integrated temperature control panel
  • Adjustable levelling feet
  • Relief / non-return valve

230 V / 50 Hz. Contact us for current pricing, lead time and installation engineering.

BK3 or BK2 — which to choose?

Both are large superyacht-grade calorifiers sharing the same 316 stainless tank, temperature control panel and levelling feet. The difference is how they heat:

  • BK3 (this model) — electric-only. No heat exchanger; instead a twin Incoloy® electric element for maximum output (4000 W or 8000 W), 200 L. Built for vessels that heat purely by generator or shore power.
  • BK2 — dual-source. Adds an engine heat exchanger alongside a 2000 W or 4000 W element, recovering free hot water from the engine cooling circuit underway. 160 L or 200 L.

Choose the BK3 for the highest pure-electric output; choose the BK2 to recover engine heat.

How it heats — high-output electric

Unlike the rest of the range, the BK3 has no engine heat exchanger — it heats purely by electricity, using a twin Incoloy® element for a high 4000 W or 8000 W output and fast recovery of its 200 L. This suits large yachts with ample generator or inverter capacity. Note the substantial current these elements draw — size the circuits, breakers and AC source accordingly.

Temperature, Legionella & usable capacity

The adjustable thermostat and integrated temperature control panel set the storage temperature. Store the water hot (60°C+) to suppress Legionella, then temper delivery to a safe ≤50°C at the outlets with a thermostatic mixing valve. A hotter store also stretches usable hot water — useful on a busy charter yacht.

Scaling up — multiple heaters in parallel or series

On larger vessels where a single tank can’t meet demand, calorifiers are installed in multiples:

  • Parallel — two or more tanks share a common cold feed and combined hot outlet, storing and delivering hot water at the same time. This roughly multiplies both the stored volume and the peak simultaneous draw — the usual choice for several bathrooms drawing at once. For it to balance, the tanks must be equally matched (same capacity and rating) and set to the same temperature, with equal-length or reverse-return pipework so they draw and refill evenly. Each tank keeps its own relief valve and expansion provision.
  • Series — the hot outlet of one tank feeds the cold inlet of the next, so the first pre-heats and the second brings the water to final temperature. The two tanks needn’t match: you can run the first (pre-heat) tank cooler and the second (final) tank hotter, and the second stage can even be a smaller tank, since it only has to lift already-warmed water the last step. The classic use is an engine heat-exchanger tank pre-heating water that then passes to an electric tank for final heating — recovering free engine heat while guaranteeing delivery temperature alongside. Series extends continuous draw but does not add simultaneous flow the way parallel does.

Match the layout to the load: parallel for peak simultaneous demand, series for pre-heat and sustained draw. Size and configure to the vessel’s hot-water demand, and confirm with your surveyor on commercial and passenger vessels.

Maintenance & spares

Service the wear items to keep it reliable: check the sacrificial anode, test the relief/non-return valve, and inspect the element for scale. The BK range uses higher-output elements and heavier-duty parts than the smaller B3/BX/BXS models, so its spares differ — contact us for the correct BK component.

Hot water circulation loops

On a vessel with long pipe runs, hot water can take a while to reach distant heads and galleys — you run the tap and wait, wasting time and precious fresh water. A hot water circulation loop fixes this: a circulation pump continuously moves hot water from the calorifier around the system and back via a return line, so hot water is available instantly at every outlet. It also keeps the whole system at temperature with no dead legs — good practice for Legionella control. Use a bronze or stainless circulation pump rated for potable hot water — such as the Calpeda NCE energy-saving circulation pump — controlled by a timer or thermostat to save energy, and insulate the loop.

Design & installation — we can help

Y3 Marine can design and install your complete hot-water system — sizing the calorifier(s), circulation loop, tempering and safety valves, and pump selection to suit your vessel and demand. Contact us to discuss your installation.

⚠ Australian Installation Requirements

All marine water heaters installed aboard vessels in Australian waters must comply with the following requirements. Failure to comply may constitute a vessel safety deficiency under the National Standard for Commercial Vessels (NSCV C5A).

  • Temperature & Pressure Relief Valve (T&PRV): A T&PRV rated and certified to AS/NZS 1271 must be fitted to this unit. CE-marked or international relief valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm compliance with your marine surveyor before commissioning.
  • Thermostatic Mixing Valve (TMV): A thermostatic mixing valve must be installed at all hot water outlets. The TMV limits delivery temperature to prevent scalding and is required as a safety measure on all commercial and passenger vessels.

Compliance is the responsibility of the installer and vessel operator. Y3 Marine recommends installation by a licensed marine plumber or qualified engineer.

Additional information

Brand

Quick

Range

Nautic Boiler BK3

Heating

Electric-only — no heat exchanger

Capacity

200 L

Tank Material

316 AISI stainless steel (Argon-welded)

Heating Element

Twin Incoloy® — 4000W or 8000W

Casing

PVC & composite

Safety Valve

Relief / non-return

Control

Integrated temperature control panel + adjustable thermostat

Voltage

230V / 50Hz

Mounting

Adjustable levelling feet