Description
📦 Dispatch & Availability: This item is available on back order. Please allow up to 10 business days to dispatch from the date of order.
The Quick Nautic Boiler B3 is a compact, high-performance marine water heater designed for yachts and motorboats from 7 m upward. Dual-source heating means it works from your engine’s cooling circuit or 240 V shore power — whichever is available at the time, with no manual switching required.
Key features of the Quick Nautic Boiler B3
- 316L stainless steel tank, Argon-welded for superior corrosion resistance
- Wide-surface AISI 316 stainless steel heat exchanger — faster engine heating than competitor units
- Incoloy® electric element with adjustable safety bi-thermostat
- Composite outer casing with high-density injected PU foam insulation
- Australian-certified combined safety relief and non-return valve (fitted)
- Stainless steel mounting brackets included — horizontal or vertical installation
- Optional thermostatic mixing valve kit (anti-scald, sold separately)
- 3-year warranty
Choosing your size
The B3 spans seven capacities from 15 to 80 L — pick the volume to match your crew and hot-water demand:
- 15–20 L: a couple or day boat — galley and one head
- 25–30 L: cruising couple or small family — galley plus a head
- 40 L: family cruising or liveaboard — comfortable back-to-back use
- 60–80 L: larger crew — several outlets drawing at once
As a general rule of thumb, allow roughly 20–30 L of tank per person aboard for comfortable hot water, and step up a size if you run several outlets back-to-back. On each size a 500 W or 1200 W element is available — the higher output recovers faster but needs a correctly sized, dedicated circuit.
How it works — dual heating
The B3 heats two ways, automatically, with no switching:
- Engine heat exchanger — the wide-surface AISI 316 coil recovers waste heat from the engine’s cooling circuit, giving free hot water on passage with nothing running but the main engine.
- Electric element — the Incoloy® element heats the tank on 240 V shore power or generator when the engine is cold.
Whichever source is available does the work, so you have hot water underway and alongside.
Temperature, Legionella & usable capacity
The adjustable bi-thermostat sets the storage temperature. Store the water hot (60°C+) to suppress Legionella, which thrives in lukewarm water, then rely on a thermostatic mixing valve to temper delivery to a safe ≤50°C at the outlets. A hotter store also stretches your usable hot water — each litre of stored water blends into more litres of warm water at the tap, effectively increasing capacity without a bigger tank.
Maintenance & genuine spares
Keep to genuine Quick parts for the wear items:
- Check the sacrificial anode every 12 months and renew it before it is fully consumed.
- Renew the heating element (with its gasket) if it fails or scales — the element removal spanner is the correct tool.
- Replace the combined safety valve if it weeps continuously or fails a pressure test, and the bi-thermostat if temperature control fails.
- For installation in petrol/LPG or vapour-risk spaces, fit the ignition-protected Anti-Flare Protection element (ISO 8846).
Specifications
| Capacity | Length | Diameter | Weight | Element options |
|---|---|---|---|---|
| 15 L | 405 mm | Ø 300 mm | 7.0 kg | 500 W / 1200 W |
| 20 L | 500 mm | Ø 300 mm | 8.1 kg | 500 W / 1200 W |
| 25 L | — | Ø 300 mm | — | 500 W / 1200 W |
| 30 L | — | Ø 300 mm | — | 500 W / 1200 W |
| 40 L | — | Ø 300 mm | — | 500 W / 1200 W |
| 60 L | — | Ø 370 mm | — | 500 W / 1200 W |
| 80 L | — | Ø 370 mm | — | 500 W / 1200 W |
Working pressure: 5 bar. All models 230 V / 50 Hz. Connections: ½″ BSP.
Scaling up — multiple heaters in parallel or series
On larger vessels where a single tank can’t meet demand, calorifiers are installed in multiples:
- Parallel — two or more tanks share a common cold feed and combined hot outlet, storing and delivering hot water at the same time. This roughly multiplies both the stored volume and the peak simultaneous draw — the usual choice for several bathrooms drawing at once. For it to balance, the tanks must be equally matched (same capacity and rating) and set to the same temperature, with equal-length or reverse-return pipework so they draw and refill evenly. Each tank keeps its own relief valve and expansion provision.
- Series — the hot outlet of one tank feeds the cold inlet of the next, so the first pre-heats and the second brings the water to final temperature. The two tanks needn’t match: you can run the first (pre-heat) tank cooler and the second (final) tank hotter, and the second stage can even be a smaller tank, since it only has to lift already-warmed water the last step. The classic use is an engine heat-exchanger tank pre-heating water that then passes to an electric tank for final heating — recovering free engine heat while guaranteeing delivery temperature alongside. Series extends continuous draw but does not add simultaneous flow the way parallel does.
Match the layout to the load: parallel for peak simultaneous demand, series for pre-heat and sustained draw. Size and configure to the vessel’s hot-water demand, and confirm with your surveyor on commercial and passenger vessels.
Hot water circulation loops
On a vessel with long pipe runs, hot water can take a while to reach distant heads and galleys — you run the tap and wait, wasting time and precious fresh water. A hot water circulation loop fixes this: a circulation pump continuously moves hot water from the calorifier around the system and back via a return line, so hot water is available instantly at every outlet. It also keeps the whole system at temperature with no dead legs — good practice for Legionella control. Use a bronze or stainless circulation pump rated for potable hot water — such as the Calpeda NCE energy-saving circulation pump — controlled by a timer or thermostat to save energy, and insulate the loop.
Design & installation — we can help
Y3 Marine can design and install your complete hot-water system — sizing the calorifier(s), circulation loop, tempering and safety valves, and pump selection to suit your vessel and demand. Contact us to discuss your installation.
⚠ Australian Installation Requirements
All marine water heaters installed aboard vessels in Australian waters must comply with the following requirements. Failure to comply may constitute a vessel safety deficiency under the National Standard for Commercial Vessels (NSCV C5A).
- Temperature & Pressure Relief Valve (T&PRV): A T&PRV rated and certified to AS/NZS 1271 must be fitted to this unit. CE-marked or international relief valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm compliance with your marine surveyor before commissioning.
- Thermostatic Mixing Valve (TMV): A thermostatic mixing valve must be installed at all hot water outlets. The TMV limits delivery temperature to prevent scalding and is required as a safety measure on all commercial and passenger vessels.
Compliance is the responsibility of the installer and vessel operator. Y3 Marine recommends installation by a licensed marine plumber or qualified engineer.