Low Pressure Pump – Seal

$294.31

Genuine FCI OEM ceramic seal kit for the stainless steel low pressure (feed) pump on Atlas+, MaxQ+, and Neptune+ watermakers. Replace every 1,000 hours or at first sign of a leak. In stock at Y3 Marine.

1 in stock

Add to Quote

Description

The FCI Low Pressure Pump Seal Kit (SKU 43-2235) is the genuine OEM ceramic mechanical seal replacement for the stainless steel centrifugal feed pump on FCI Atlas+, MaxQ+, and Neptune+ watermakers. The low pressure pump draws seawater from the sea strainer and feeds it to the high-pressure pump — a leaking pump seal is an early failure warning that should not be ignored, as a worsening leak will cause the system to shut down on low feed pressure. The Atlas+, MaxQ+, and Neptune+ use a stainless steel pump body with a ceramic mechanical face seal — a more robust configuration than the Noryl polymer pump on smaller FCI models, suited to the higher flow demands of these large-output systems. FCI recommends replacing the ceramic seal every 1,000 operating hours or at the first sign of a leak, whichever comes first. In stock at Y3 Marine for immediate despatch.

Key Features

  • Genuine FCI OEM ceramic seal kit — SKU 43-2235, correct specification for the stainless steel LP pump (SS volute, SS bracket) on Atlas+, MaxQ+, and Neptune+ watermakers
  • Ceramic mechanical face seal — more robust than polymer seals; suited to continuous seawater service in high-flow applications
  • Service interval: replace every 1,000 operating hours or when a leak first develops — do not run through a weeping seal
  • Check LP pump for leaks at the 50-hour break-in service and at every subsequent scheduled maintenance
  • Compatible with the 1 HP stainless steel centrifugal LP pump assembly (FCI P/N 93-0047)
  • Not the same as the Noryl pump seal kit (SKU 43-7205) used on Aquamiser+ and Aqualite — confirm your pump body material before ordering
  • Stocked by Y3 Marine, Australia’s authorised FCI dealer — available for immediate despatch

Typical Superyacht Applications

  • Scheduled LP pump seal replacement at the 1,000-hour service interval on Atlas+, MaxQ+, or Neptune+ watermakers
  • Reactive repair following low feed pressure shutdown caused by a leaking pump seal
  • Preventive replacement during a haul-out or extended lay-up refit

Installation & Compatibility Notes

  • Compatible with: FCI Atlas+ (all models), MaxQ+ (all models), Neptune+ (all models) — stainless steel LP pump configuration
  • Not compatible with Aquamiser+ or Aqualite — those use the Noryl 6-bolt pump seal kit (SKU 43-7205)
  • Isolate seawater feed and disconnect electrical power before disassembling pump
  • Remove the four 3/8″-16 bolts from the volute; hold motor shaft with screwdriver via bearing cap access; remove impeller counter-clockwise
  • Refer to the Atlas+ / MaxQ+ / Neptune+ User Manual for full ceramic seal replacement procedure and exploded view

Brand

FCI Watermakers