Johnson Viking Power Vacuum Non-Return Valve

Genuine non-return (double check) valve for the SPX Viking Power Vacuum — holds vacuum in a vacuum-toilet system.

Johnson Pump Marine by SPX FLOW. Supplied by Y3 Marine.

Add to Quote
SKU: 01-36074 Categories: ,

Description

Genuine non-return / double check valve for the SPX Viking Power Vacuum — the valve that lets the Vacuum hold vacuum in a vacuum-toilet system. Renew if the system won’t build or hold vacuum, or the pump backflows.

The Vacuum shares its diaphragm service kit with the VP32 (09-47181).

Fitting & service guide — Viking diaphragm pump service

General guidance for servicing a Johnson Viking Power diaphragm pump. Follow the pump’s SPX service manual for exact parts and orientation.

1. Make it safe

  • Isolate the pump (de-power) and the line; relieve pressure and have a bucket and rags ready.
  • PPE for the duty — gloves/eye protection for black- or grey-water pumps; avoid skin contact with oily bilge water and dispose of it responsibly (never over the side — MARPOL).

2. Strip the wet end

  1. Record orientation (photograph each step).
  2. Open the housing and lift out the diaphragm; note the dome direction.
  3. Remove the valves / valve rubbers — note that inlet and outlet face opposite ways; a reversed valve stops the pump dead.

3. Renew & reassemble

  1. Renew the diaphragm and both valves together — they wear as a set. Clean the seats and body.
  2. Refit valves the correct way round, then the diaphragm; seat the housing and tighten fasteners evenly in a diagonal sequence (don’t overtighten plastic).
  3. Reconnect, re-power and test: confirm prime, full flow and no back-leak or weeps.

Where the housing itself is cracked or worn, fit the complete pump housing; otherwise the diaphragm/valve service kit restores a sound pump. If flow is still weak, check the suction for air leaks and the strainer for blockage.

Johnson Pump Marine by SPX FLOW. Supplied by Y3 Marine.