Description
The Johnson Ultima Switch is the sealed Mirus field-effect switch that gives the Ultima bilge pumps their automatic operation — no float, no moving parts, no mercury. Because it never touches the water it won’t corrode or foul on oil, and a built-in delay stops false starts. 12 / 24 V.
If an Ultima pump won’t start automatically, or won’t switch off, the switch is the first thing to replace. Also catalogued as 34-36303 / 36303.
Fitting & service guide — bilge switch / alarm / panel
- De-power and pull the fuse before wiring.
- Mount a float/field switch beside the pump, slightly higher, with clear room so it can’t foul hoses or wiring; mount a high-water alarm sensor above the pump cut-in level.
- Wire to a permanent, fused feed so the pump/alarm stays live with the main panel off; on a 3-way panel wire manual / off / auto. Marine crimps and heat-shrink, joints above the waterline.
- Test by raising the water: the pump must cut in and out cleanly, and the alarm must sound. Back every auto pump with an independent high-water alarm, and test monthly.
Johnson Pump Marine by SPX FLOW. Supplied by Y3 Marine.