Description
The Johnson SPX Cartridge submersible bilge pump pairs a compact thermoplastic pump with a genuinely serviceable design: the whole motor/impeller is a single cartridge that twist-locks in and out of the strainer base, so a jammed or failed pump is cleared or swapped afloat without cutting hose or disturbing the base. Available at ~3,800 and 4,731 LPH (1000 / 1250 GPH), 12 V and 24 V DC, with a water-cooled motor and lip-seal shaft.
Performance
| Model | Flow (open) | Port | 12 V draw / fuse |
|---|---|---|---|
| 1000 GPH | ~3,800 LPH | 3⁄4″ | per data sheet |
| 1250 GPH | 4,731 LPH · 4,380 LPH @ 3 ft head | 28 mm (1⅛″) | 3 A / 5 A |
24 V versions draw roughly half the 12 V current.
Choosing the right capacity
Bilge-pump ratings are open-flow figures (ISO 8849 / ABYC H-22); installed output is always lower once you add static head, hose length, elbows and a check valve — the 1250, for example, moves 4,731 LPH open but about 4,380 LPH at a metre of lift. Size for the volume of nuisance water you expect, with margin, and keep the discharge run short and smooth-bore.
Cartridge design — service in seconds
The base and strainer stay installed and hose-connected; the motor cartridge lifts straight out. Keep a spare aboard and a failed bilge pump becomes a two-minute fix — see the matching SPX bilge cartridge for the drop-in replacement motor.
Nuisance water, not damage control
This is a compact intermittent-duty pump for rain, spray, shaft-gland weep and washdown — not a means of dewatering a holed hull. Emergency dewatering is the job of a dedicated engine-driven or portable crash pump, and on commercial and survey vessels it falls under AMSA / NSCV bilge-pumping requirements. Fit it as one layer of the bilge system, and control it with a float switch or panel (it is a non-automatic pump).
Key features
- All-in-one removable motor cartridge — service without re-plumbing
- ~3,800 / 4,731 LPH (1000 / 1250 GPH), 12 V and 24 V DC
- Water-cooled motor; thermoplastic body; lip-seal shaft
- ¾″ discharge (1000) · 28 mm / 1⅛″ (1250)
- Drop-in replacement cartridge available as a low-cost spare
- Non-automatic — pair with a float switch or panel
MARPOL & oily-water discharge
A bilge pump discharges whatever is in the bilge overboard, so oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm and never discharge in a port or a special area; smaller craft without a separator must hold oily bilge water and land it ashore. A visible oil or diesel sheen means overboard discharge is illegal — keep the bilge clean and oil-free and route to a holding tank or separator where contamination is possible. This matters most with automatic pumps, which can discharge unattended.
Test it monthly
A bilge pump that fails quietly is only found when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: raise the water level or trigger the float/sensor, confirm the pump runs and moves water, and check that the strainer basket is clear, the check valve seats, and the discharge runs freely with no air lock. Confirm any automatic model cuts in and out on its own, and keep a spare strainer basket and service kit aboard.
Dealer notes
- Removable cartridge — keep a spare and a failed pump is a two-minute swap without re-plumbing (see the SPX bilge cartridge spare).
- Non-automatic — pair with a float switch or panel.
- Water-cooled motor — don’t run dry; 24V draws roughly half the 12V current. Test monthly.
Do not run dry. The water-cooled motor relies on the water it pumps for cooling — extended dry running will overheat and damage it.
Johnson Pump Marine by SPX FLOW. Supplied by Y3 Marine. Open-flow ratings (ISO 8849); confirm current draw and fusing against the Johnson data sheet for the model and voltage.