Johnson Pump Ultima Automatic Submersible Bilge Pump — Integrated Switch (600–1250)

Price range: $218.00 through $295.00

Johnson Pump Ultima — compact automatic submersible bilge pump with sealed integrated Ultima field-effect switch (no float, no mercury). Four sizes, 2,280–4,740 LPH, 12 V DC. Dura-Port discharge (600–1000), removable check valve included.

Johnson Pump by SPX FLOW.

Add to Quote
SKU: N/A Category:

Description

The Johnson Pump Ultima automatic submersible bilge pump is a sleek, compact unit with an integrated electronic switch — ready to install and run for years of reliable service. Available in four sizes from 2,280 to 4,740 LPH, all 12 V DC. The integrated Ultima switch uses the sealed Mirus field-effect detector — no float, no moving parts, no mercury, and never in contact with the water, so it will not corrode or foul on oil and debris. It switches the pump on at a 50 mm (2″) water level and off at 20 mm (¾″), with a 3-second delay to prevent false starts.

Performance

Model Flow (straight) Flow @1 m head Current Fuse Connection
Ultima 600 2,280 LPH 1,920 LPH 2.5 A 5 A ¾″
Ultima 800 3,060 LPH 2,280 LPH 3 A 5 A ¾″
Ultima 1000 3,840 LPH 2,640 LPH 3.2 A 5 A ¾″
Ultima 1250 4,740 LPH 3,060 LPH 3 A 5 A 1⅛″ & 1¼″

Choosing the right capacity

Bilge-pump ratings are open-flow figures (ISO 8849 / ABYC H-22); installed output is always lower once you add static head, hose length, elbows and the check valve. Size on the at-head column for your actual lift — the Ultima 1000, for example, moves 3,840 LPH open but about 2,640 LPH at a metre of head. Choose the size for the volume of nuisance water you expect, with margin, not for a hoped-for emergency figure.

Nuisance water, not damage control

The Ultima is a compact intermittent-duty automatic pump for rain, spray, shaft-gland weep and washdown — not a means of dewatering a holed hull. Emergency dewatering is the job of a dedicated engine-driven or portable crash pump, and on commercial and survey vessels it falls under AMSA / NSCV bilge-pumping requirements. Fit the Ultima as one layer of a system, not the last line of defence.

Why the integrated Ultima switch

The Ultima switch senses water with a sealed field-effect detector rather than a float, so there is nothing to jam with debris, oil or a stuck float, no mercury and nothing exposed to corrode. It switches on at a 50 mm (2″) water level and off at 20 mm (¾″), with a 3-second delay against false starts. Being built in, there is no separate switch to mount and wire — but it is still one device, so fit an independent high-water alarm as a backup rather than relying on a single sensor.

Redundancy & alarms

On a vessel left unattended, run a primary automatic pump at the lowest point and a larger backup mounted slightly higher, each on its own circuit, with an independent high-water alarm above them. The Ultima suits the primary role in small to mid bilges; step up to the Heavy Duty range for the backup or for larger compartments.

Wiring & voltage drop

Draw is modest (2.5–3.2 A by model), but the 0.9 m factory lead almost always needs extending — size the run for no more than about 3% voltage drop and keep it short, since undersized cable costs the pump flow and runs the motor hot. Fuse at the source at 5 A, and arrange the circuit so an automatic pump stays live with the main battery switch off, to suit your survey requirements.

Discharge & anti-siphon

The 600–1000 models use Dura-Port straight and 90° fittings — smooth-bore, with a free-spinning nut so there is no over-tightening or stress cracking; the 1250 takes 1⅛″ / 1¼″ hose directly (no Dura-Port). Run the discharge up and out above the waterline and fit a vented (anti-siphon) loop where the outlet is at or near the waterline. Keep the hose at full bore, minimise elbows, and inspect the supplied check valve for trapped debris when you service the strainer.

Mounting & maintenance

Mount at the lowest accessible point on a solid base where the strainer basket can be reached for cleaning. Keep the bilge free of oil and fuel, keep the basket clear, and test the pump and switch monthly by raising the water level. Genuine baskets and Dura-Port parts are listed under Johnson Pump Ultima Bilge Spares.

Part numbers

Model Part No.
Ultima 600 32-47258-008
Ultima 800 32-47259-008
Ultima 1000 32-47260-008
Ultima 1250 32-47261-005

MARPOL & oily-water discharge

A bilge pump discharges whatever is in the bilge overboard, so oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm and never discharge in a port or a special area; smaller craft without a separator must hold oily bilge water and land it ashore. A visible oil or diesel sheen means overboard discharge is illegal — keep the bilge clean and oil-free and route to a holding tank or separator where contamination is possible. This matters most with automatic pumps, which can discharge unattended.

Test it monthly

A bilge pump that fails quietly is only found when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: raise the water level or trigger the float/sensor, confirm the pump runs and moves water, and check that the strainer basket is clear, the check valve seats, and the discharge runs freely with no air lock. Confirm any automatic model cuts in and out on its own, and keep a spare strainer basket and service kit aboard.

Dealer notes

  • Integrated Mirus field-effect switch — no float, no mercury, nothing in the water to foul; still fit an independent high-water alarm.
  • Switches on at 50 mm, off at 20 mm, with a 3-second delay against false starts.
  • Good primary pump for small-to-mid bilges; step up to the Heavy Duty range for the backup or larger compartments.
  • Wire to stay live with the main switch off (survey), fuse at 5 A, and test the pump and switch monthly.

Do not run dry. The water-cooled motor relies on the water it pumps for cooling — extended dry running will overheat and damage it.

Johnson Pump by SPX FLOW.

Additional information

Configuration

Ultima 600 — 2,280 LPH — 12V, Ultima 800 — 3,060 LPH — 12V, Ultima 1000 — 3,840 LPH — 12V, Ultima 1250 — 4,740 LPH — 12V

Switch Type

Integrated Ultima field-effect switch — no moving parts, no mercury

Switch Activation

On at 50 mm (2″) water, off at 20 mm (¾″), 3-second false-start delay

Pump Body

ABS — fuel resistant — saltwater tested

Voltage

12V DC

Max Current

2.5–3.2 A (by model)

Fuse

5 A

Wiring

16 GA (1.3 mm²) — 0.9 m lead

Discharge Ports

Dura-Port straight & 90° included (Ultima 600–1000); Ultima 1250 uses 1⅛″ / 1¼″ hose — no Dura-Port

Check Valve

Removable check valve + rubber compression washer included

Dimensions

600–1000: 142 × 82 × 105 mm · 1250: 142 × 82 × 117 mm · weight 0.66 kg

Brand

Johnson Pump Marine

Brand

Johnson Pump Marine