Johnson Pump Heavy Duty Submersible Bilge Pump (1600 / 2200 / 4000)

Price range: $251.00 through $568.00

Johnson Pump Heavy Duty submersible bilge pumps — 6,000 / 7,800 / 15,120 LPH in 12 V & 24 V DC. Liquid-cooled 12-pole double-ball-bearing motor, mechanical seal (2200/4000), removable check valve, universal base plate. Available pump-only or with integrated Ultima automatic switch (1600 & 2200). ISO 8849 · CE.

Johnson Pump by SPX FLOW.

Add to Quote
SKU: N/A Category: Tag:

Description

The Johnson Pump Heavy Duty submersible bilge pumps are built for the demands of commercial and superyacht duty — a liquid-cooled 12-pole motor on double ball bearings for long service life, driving a high-flow impeller tuned for both head and flow. The range spans 6,000 to 15,120 LPH in 12 V and 24 V DC, with a universal base plate, a choice of two port sizes and a removable check valve included.

Performance

Model Flow straight Flow @1 m head 12 V A / fuse 24 V A / fuse Connection Seal
1600 6,000 LPH 5,880 LPH 7 A / 10 A 3.5 A / 6 A 1⅛″ & 1¼″ Lip
2200 7,800 LPH 7,200 LPH 7.5 A / 12 A 4.5 A / 6 A 1⅛″ & 1¼″ Mechanical
4000 15,120 LPH 9,840 LPH 15 A / 25 A 7.5 A / 15 A 1½″ & 2″ Mechanical

Choosing the right capacity

Bilge-pump ratings are open-flow figures measured to ISO 8849; real installed output is always lower once you add static head (the lift up to the discharge), hose length, elbows and the check valve. Size on the at-head column for your actual lift, then allow a generous margin — a pump rated 6,000 LPH open flow can deliver little more than half that through a typical run with a metre of lift, a check valve and a couple of 90° elbows. Match the model to the vessel and the volume of nuisance water you expect, not to a hoped-for emergency capacity.

Nuisance water, not damage control

Even the 4000 (15,120 LPH open flow) is an intermittent-duty dewatering pump for rain, spray, shaft-gland weep and washdown — not a means of keeping a holed hull afloat. Emergency dewatering is the job of a dedicated engine-driven or portable crash pump, and on commercial and survey vessels it is covered separately under AMSA / NSCV bilge-pumping requirements. Fit these pumps as one layer of a system, never as the last line of defence.

Switch options

The 1600 and 2200 are offered pump-only or with an integrated Ultima automatic switch — a sealed Mirus field-effect detector (no float, no moving parts, no mercury) that turns the pump on at a 50 mm (2″) water level and off at 20 mm (¾″), with a 3-second delay to prevent false starts. The 4000 is supplied pump-only and pairs with a separate float or electronic switch.

Redundancy & alarms

On any vessel left unattended, best practice is at least two pumps: a primary automatic pump at the lowest point and a larger backup mounted slightly higher, each on its own circuit and switch. Always pair an automatic pump with an independent high-water alarm — the switch that runs the pump should never be the only thing telling you the bilge is filling. A three-way panel (manual / off / auto) lets the crew override for testing or a manual pump-down.

Wiring & voltage drop

These are high-draw motors — up to 15 A at 12 V on the 4000. The 1.8 m factory lead almost always needs extending, so size the whole run for no more than about 3% voltage drop and keep it short: undersized cable robs the motor of voltage and the pump of flow, and runs the motor hot. Fuse at the source per the table, and arrange the automatic circuits so the pump stays live with the main switch off, to suit your survey requirements.

Discharge & anti-siphon

Run the discharge up and out through a skin fitting above the waterline, and fit a vented (anti-siphon) loop where the outlet sits at or near the waterline so the sea cannot siphon back into the bilge. Keep the hose at full port bore, use smooth-bore reinforced hose and minimise elbows — every reduction and bend costs flow. The removable check valve limits back-drain from the discharge column but can trap debris, so inspect it when you service the strainer.

Seals, duty & maintenance

The lip seal on the 1600 suits intermittent duty; the mechanical seal on the 2200 and 4000 stands up to more frequent or dirtier service. Keep the bilge free of oil and fuel (both attack seals and impellers), keep the strainer basket clear, and test every pump and switch monthly. Genuine strainer baskets and discharge ports are listed under Johnson Pump Heavy Duty Bilge Spares.

Part numbers

Model / version 12 V 24 V
1600 Pump only 32-1600-01 32-1600-02
1600 Ultima auto 32-1600UC-01 32-1600UC-02
2200 Pump only 32-2200-01 32-2200-02
2200 Ultima auto 32-2200UC-01 32-2200UC-02
4000 Pump only 32-4000-01 32-4000-02

MARPOL & oily-water discharge

A bilge pump discharges whatever is in the bilge overboard, so oily-water law applies. Under MARPOL Annex I — given effect in Australia by the Protection of the Sea (Prevention of Pollution from Ships) Act 1983 and enforced by AMSA — it is an offence to discharge bilge water containing oil above the permitted limit. Larger vessels must pass machinery-space bilge water through an approved oily-water separator to below 15 ppm and never discharge in a port or a special area; smaller craft without a separator must hold oily bilge water and land it ashore. A visible oil or diesel sheen means overboard discharge is illegal — keep the bilge clean and oil-free and route to a holding tank or separator where contamination is possible. This matters most with automatic pumps, which can discharge unattended.

Test it monthly

A bilge pump that fails quietly is only found when it is finally needed. Test every bilge pump and its switch or sensor at least monthly: raise the water level or trigger the float/sensor, confirm the pump runs and moves water, and check that the strainer basket is clear, the check valve seats, and the discharge runs freely with no air lock. Confirm any automatic model cuts in and out on its own, and keep a spare strainer basket and service kit aboard.

Dealer notes

  • Size on the at-head column, not open flow — a metre of lift plus elbows and a check valve roughly halves output.
  • 1600 = lip seal (intermittent duty); 2200 and 4000 = mechanical seal for harder, dirtier or more frequent service.
  • 1600/2200 available with integrated Ultima auto switch; 4000 is pump-only — pair with a float/electronic switch and an independent high-water alarm.
  • High draw (up to 15 A @12V on the 4000) — extend the lead in heavy gauge for under 3% volt drop, fuse at source, and test monthly.

Do not run dry. The water-cooled motor relies on the water it pumps for cooling — extended dry running will overheat and damage it.

Johnson Pump by SPX FLOW.

Additional information

Configuration

1600 — 6,000 LPH — 12V — Pump only, 1600 — 6,000 LPH — 24V — Pump only, 1600 — 6,000 LPH — 12V — Ultima auto switch, 1600 — 6,000 LPH — 24V — Ultima auto switch, 2200 — 7,800 LPH — 12V — Pump only, 2200 — 7,800 LPH — 24V — Pump only, 2200 — 7,800 LPH — 12V — Ultima auto switch, 2200 — 7,800 LPH — 24V — Ultima auto switch, 4000 — 15,120 LPH — 12V — Pump only, 4000 — 15,120 LPH — 24V — Pump only

Motor

12-pole, double ball bearing — liquid cooled

Seal Type

1600: Lip seal · 2200 & 4000: Mechanical seal

Pump Body

ABS — high-impact, non-corrosive

Shaft

Stainless steel

Switch Options

Pump-only, or integrated Ultima automatic switch (1600 & 2200)

Hose Size

1600 / 2200: 1⅛″ & 1¼″ · 4000: 1½″ & 2″

Wiring

16 AWG (1.31 mm²) — 1.8 m lead

Current / Fuse

7–15 A / 10–25 A at 12V · 3.5–7.5 A / 6–15 A at 24V (by model)

Check Valve

Removable check valve included · universal base plate

Certifications

ISO 8849 (electrically-operated bilge pumps) · CE

Brand

Johnson Pump Marine

Brand

Johnson Pump Marine