Description
The Johnson Pump bilge pump control panel puts manual and automatic bilge pumping under one helm switch, with an integrated fuse holder and an operating light that confirms at a glance the pump is running.
Two versions
- 3-Way — ON / AUTO / OFF (34-1224 12 V, 34-1225 24 V). The one to fit for a proper automatic bilge install. In AUTO the pump runs on its own via an automatic float / Ultima switch, AS888 or an electronic float switch; ON overrides for a manual pump-out; OFF isolates it.
- 2-Way — ON / OFF (34-82004 12 V, 34-82004-24V 24 V). Straightforward manual on/off control where automatic switching isn’t needed.
(In the US catalogue the 3-Way is numbered 82044 / 82044-24V and the 2-Way 82004 — same panels.)
Installation & wiring
Panel-mounts at the helm or switch board (73 × 60 mm, 40 mm deep). Wire battery positive through the panel’s fuse holder to the pump, with the automatic switch feeding the AUTO circuit so it can start the pump while you retain manual override. Fit a 6.3 × 32 mm fuse sized to the pump’s current draw — fuse not included.
Dealer notes
- Fit the 3-Way for any auto bilge system — AUTO plus manual override is what crews actually want; the 2-Way suits a purely manual pump.
- Pair it with the right switch — AS888 automatic switch or an electronic float switch on the AUTO circuit.
- The operating light is your tell — a glance confirms the pump is actually running, not just switched.
- Fuse correctly for the pump’s draw, and match 12 / 24 V to the boat’s system.
Key features
- 2-Way (ON/OFF) or 3-Way (ON/AUTO/OFF) · 12 V and 24 V
- Integrated fuse holder (6.3 × 32 mm) and operating light
- AUTO works with AS888, Ultima or electronic float switches
- Matt-black panel, 73 × 60 mm · helm / switch-board mount
- Genuine Johnson / SPX · supplied on back order, quote-only
Fitting & service guide — bilge switch / alarm / panel
- De-power and pull the fuse before wiring.
- Mount a float/field switch beside the pump, slightly higher, with clear room so it can’t foul hoses or wiring; mount a high-water alarm sensor above the pump cut-in level.
- Wire to a permanent, fused feed so the pump/alarm stays live with the main panel off; on a 3-way panel wire manual / off / auto. Marine crimps and heat-shrink, joints above the waterline.
- Test by raising the water: the pump must cut in and out cleanly, and the alarm must sound. Back every auto pump with an independent high-water alarm, and test monthly.
Johnson Pump Marine by SPX FLOW. Supplied by Y3 Marine.