Description
The Johnson Pump AirV 3-280 Flangemount is a heavy-duty marine radial blower delivering 163 CFM (280 m³/hr) for continuous engine room ventilation and pre-start compartment purging on sailing yachts and motor cruisers. Part of SPX Flow’s AirV centrifugal range, the 3-280 is built to NMMA and USCG 183.410 ignition-protection requirements, making it fully compliant for installation in petrol engine compartments where the mandatory ISO 9094 four-minute purge cycle applies. Its double ball bearing motor, anti-shock ABS housing, and stainless steel shaft and fasteners are engineered for continuous bilge-atmosphere operation. At this airflow rating, a matched supply-and-extract pair delivers 326 CFM (556 m³/hr) — sufficient for 10 air changes per hour (ACH) in engine compartments up to approximately 55 m³, covering most installations on vessels to 50 ft.
Key features — AirV 3-280 flangemount
- 163 CFM (280 m³/hr) continuous-duty radial (centrifugal) airflow
- 75 mm (3″) slip-on inlet hose connection — fits standard 3″ bilge blower ducting
- Rectangular flanged outlet (92 × 80 mm) for direct duct or deck fitting attachment
- Double ball bearing motor rated for continuous engine-room ambient temperatures
- High-impact anti-shock ABS housing; stainless steel shaft and fasteners
- Low current draw: 3.9 A (12 V DC) / 2.5 A (24 V DC)
- CE marked: ISO 9097:1991, ISO 8846 (ignition protection), ISO 10133 (electrical systems)
- Compliant with NMMA and USCG 183.410
- Compact flangemount footprint — 198 × 171 × 195 mm (H×W×L)
- 1-year limited manufacturer warranty
Typical Applications
- Pre-start engine compartment purging — satisfies ISO 9094 mandatory 4 air changes in 4 minutes for enclosed petrol engine spaces
- Continuous engine room ventilation at 10 ACH minimum — sailing yachts and light motor cruisers to 50 ft
- Galley exhaust and heads extract in ducted ventilation systems aboard sailing yachts
- Battery compartment hydrogen venting — maintains safe atmospheric concentration below the lower explosive limit (LEL)
- General bilge ventilation and accommodation air movement in restricted duct runs
Centrifugal Blower vs Axial Fan
Centrifugal blowers are the right choice for restrictive ducting — runs with bends, grilles, deck fittings, and any meaningful hose length. Their static pressure characteristic maintains rated airflow against system resistance; the more restricted the duct, the more a centrifugal blower outperforms an axial fan. Axial fans are optimised for free-flowing installations — short, straight, low-restriction paths where they can move very high air volumes efficiently, but where duct resistance would significantly derate their output. For a typical yacht engine room with a louvred intake, a 3–8 m hose run, and two or three bends, a centrifugal blower is the correct tool. When compartment size demands airflow beyond 250 CFM per position, or where the installation allows a near-straight bulkhead-to-bulkhead run, the Centek axial range is the step up.
Installation & Compatibility Notes
- Flangemount — four-screw footprint on any flat bulkhead or horizontal surface; inlet slip-on, outlet rectangular flange
- Inlet: 75 mm (3″) slip-on hose connection; outlet: 92 × 80 mm flange — use a duct reducer or adaptor to connect standard round ducting to the rectangular outlet
- Install with the airflow direction arrow aligned to the intended flow (supply or extract)
- Recommended fuse: 5 A (12 V DC) / 5 A (24 V DC)
- For mid-duct installation without a bulkhead penetration, consider the AirV 4-550 Flexmount with slip-on connections on both ports