The Johnson Aqua Jet (compact) is the entry-level on-demand fresh-water pump — a small diaphragm pump delivering 3.8 L/min at 35 psi on 12 V DC, with a built-in pressure switch so it runs automatically when a tap is opened. Self-priming and low-draw, it’s the neat, low-cost choice for a single galley tap or a simple washdown on tenders and day boats.
Specifications
| Spec | Value |
|---|---|
| Flow | 3.8 L/min |
| Pressure cut-off | 35 psi |
| Voltage | 12 V DC |
| Control | Integral pressure switch — automatic on-demand |
| Priming | Self-priming |
Choosing between the three Aqua Jet pumps
Y3 Marine stocks three Aqua Jet demand pumps for different jobs — all self-priming, on-demand pumps with a built-in pressure switch, but suited to very different systems:
- Aqua Jet (compact — 3.8 L/min, 35 psi) — the entry pump for a single tap or a very small system on a tender or day boat. Lowest flow, pressure, current draw and cost.
- Aqua Jet WPS (2.9–5.2 GPM / 11–20 L/min, 41 psi) — the standard multi-outlet fresh-water pump. Pick the flow rating to suit the number of outlets (galley, head, shower); pair with an accumulator to smooth flow and cut cycling.
- Aqua Jet Flow Master 5.0 (variable flow to 5 GPM / 19 L/min, 51 psi) — the premium pump: electronic variable-speed control holds constant pressure and smooth flow however many taps are open, runs without an accumulator, and is the quietest of the three.
In short: single outlet → Aqua Jet; standard system → WPS (sized to outlets); large system or premium feel → Flow Master.
Installation & dealer notes
- Inlet strainer — always fit one. Grit reaching the diaphragm valves is the number-one cause of weak pressure and leaks.
- Accumulator tank. Fit on the pressure side to smooth pulsation, steady tap flow and cut pump cycling — quieter, with longer pump life.
- Flexible connections. Plumb a short length of flexible hose at inlet and outlet so the pump doesn’t transmit noise and vibration into the hull.
- Don’t starve the inlet. Keep the suction line short, full-bore and air-tight — a restricted or leaky inlet causes loss of prime and pulsing.
- Wiring. Size the cable for the run and fuse per the data sheet; these are automatic pumps — leave them powered and they run on demand.
Common faults
- Short-cycling / won’t stop: flat or missing accumulator, worn pressure switch, or a small leak downstream.
- Loss of prime / pulsing: air leak on the suction side or a blocked inlet strainer.
Key features
- Compact on-demand demand pump — 3.8 L/min @ 35 psi, 12 V
- Built-in pressure switch — automatic operation
- Self-priming; low current draw; quiet
- Ideal for a single outlet or a small fresh-water / washdown system