Description
The Johnson multi-port shower sump system collects grey water from the shower, sinks and other drains in a sealed box and pumps it automatically overboard or to a grey-water tank — so it never sits in the bilge to go stagnant and smell. Three inlet ports feed one compact sump with a 972 GPH (61 L/min) pump, an automatic Ultima switch, a built-in check valve and a clear lid you can see the filter through.
Specifications
| Spec | Value |
|---|---|
| Flow | 61 L/min (972 GPH) straight · 53 L/min (844 GPH) @ 1 m head |
| Current / fuse | 3.4 A / 5 A |
| Voltage | 12 V DC |
| Inlet ports | 3 × 19 mm (3⁄4″) or 38 mm (1½″) |
| Discharge | 19 mm (3⁄4″) |
| Switch | Automatic Ultima (sealed field-effect — no moving float) |
| Body | White thermoplastic box · clear acrylic lid |
Why the Ultima switch and clear lid matter
Float-type sump switches are the usual failure point — hair and soap scum jam the float, so the pump won’t start (and the sump overflows) or won’t stop. The Ultima switch senses water electronically with no moving float, so there is nothing to stick. The clear lid lets you see the removable pump and inlet filter at a glance, and both lift out for cleaning — the filter catches hair before it can clog the pump.
Installation
- Mount the sump box below the shower tray and drain points so grey water gravity-feeds into it.
- Connect the shower, basins and any AC condensate to the 3⁄4″ or 1½″ inlets; blank off any unused port.
- Run the 3⁄4″ discharge to a skin fitting above the waterline with a vented loop / anti-siphon so waste can’t back-siphon into the sump.
- Fuse at 5 A and wire the Ultima switch per the instructions; keep the box accessible for cleaning.
Maintenance
Lift the clear lid and clean the inlet filter regularly — trapped hair and soap are the number-one cause of slow drainage and a smelly sump. Flush the box through occasionally, and check the built-in check valve seals so waste can’t drain back.
Troubleshooting
- Slow drainage / won’t clear — clogged inlet filter or a restricted / kinked inlet; clean the filter.
- Pump won’t run — fouled Ultima sensor, blown fuse, or a blocked discharge.
- Pump won’t stop / cycles — sensor fouled, or the check valve leaking back so the box refills.
- Smell — standing grey water; clean the filter and flush the box, and confirm the pump empties it fully.
Key features
- Multi-port sump — 3 inlets handle shower, sinks and condensate from one box
- 972 GPH (61 L/min) pump, 12 V, 3.4 A / 5 A fuse
- Automatic Ultima switch — no float to jam on hair or soap
- Clear lid; removable pump and inlet filter for easy cleaning
- Built-in check valve prevents back-drainage