Description
Jabsco Mag-Drive Pump — Seal-Less Centrifugal
The Jabsco Mag-Drive is a seal-less, magnetically coupled centrifugal pump for small, sealed circulation loops. Instead of a shaft that passes through a seal into the motor, the impeller is spun by a magnet through a solid casing wall — so there is no shaft seal, and no path for the fluid to ever leak. It is a low-flow, low-head circulator: up to 24 L/min open flow (12.5 L/min @ 1 m head) on a tiny 1.2–1.8 A draw, silent and effectively maintenance-free. Dual-voltage — runs on 12 V or 24 V.
Specifications
| Spec | Value |
|---|---|
| Flow | Up to 24 L/min open · 12.5 L/min @ 1 m head |
| Head / pressure | Low — a circulator, not a pressure pump |
| Current | 1.2–1.8 A |
| Drive | Seal-less magnetic coupling — zero leakage |
| Voltage | 12 / 24 V DC (dual-voltage) |
| Suction | Flooded — not self-priming · do not run dry |
Why mag-drive (seal-less)?
The shaft seal is the part that fails on an ordinary circulating pump — it wears, weeps and eventually lets coolant or glycol escape. A mag-drive has no seal to fail:
- Zero leakage. The pump chamber is fully closed; the motor is magnetically isolated from the fluid. Nothing can drip onto machinery or into the bilge — ideal for glycol and sensitive fluids.
- Maintenance-free. No seal to service or replace; the brushless motor is rated for very long life.
- Quiet & low-power. 1.2–1.8 A and near-silent — built to run continuously.
- Corrosion-tolerant running gear (ceramic shaft / bushes) suits salt water and glycol loops.
The trade-off is flow: a mag-drive moves far less water than a sealed DC centrifugal. That is by design — it is a precision circulator, not a mover of bulk water.
Where it fits — low flow is the point
Compare it to our Jabsco Cyclone (a sealed DC centrifugal, ~110 L/min): the Cyclone wins on sheer flow for a big loop; the Mag-Drive wins where leak-free, set-and-forget circulation of a small loop matters more than volume. Choose the Mag-Drive for:
- Small marine air-conditioning — a single fan-coil chilled-water loop.
- Refrigeration & ice-makers — a small glycol or condenser-water loop that must never leak.
- Electronics / battery / inverter cooling loops.
- Small hydronic heating and any closed loop circulating glycol or treated water.
Installation & dealer notes
- Flooded suction — essential. Mag-drive pumps are not self-priming; mount at or below liquid level so the chamber stays full.
- Never run dry. The liquid cools and lubricates the magnetic bushes; running dry overheats and wears them.
- Bleed the loop on commissioning — an air-locked circuit gives no flow.
- Low head — keep the circuit low-resistance; it will not push through long or restricted runs.
Common faults
- No / low flow: air-locked, suction not flooded, or the loop too restrictive.
- Noisy / hot / stalled: run dry, or debris jamming the magnetic rotor.
Key features
- Seal-less magnetic drive — zero leakage, no seal to fail
- Brushless, quiet, very low draw (1.2–1.8 A) — continuous duty
- Up to 24 L/min — precision circulator for small sealed loops
- Glycol- and salt-water-tolerant running gear
- Small AC chilled-water, refrigeration, electronics & hydronic loops
- Dual-voltage — runs on 12 V or 24 V
Genuine Jabsco (Xylem). Supplied by Y3 Marine.