Description
The Jabsco 75mm flangemount blower intermittent duty (35115-0020) is a compact 12 V DC bilge ventilator purpose-built for intermittent-duty pre-start purging of enclosed petrol and diesel engine compartments. Delivering 105 CFM (3.0 m³/min) through 75 mm ducting, a single unit achieves the ISO 9094-mandated four air changes in four minutes for compartments up to approximately 3 m³ — the working volume of a typical single-engine bay on a sailing yacht or small motor cruiser to around 50 ft. Four-screw bulkhead mount, salt-air-rated reinforced plastic housing, NMMA Type Accepted.
Ignition-protected to USCG 183.410 and ISO 8846 — certified safe for enclosed fuel compartments and spaces where flammable vapours may accumulate.
Key features — Jabsco 75mm flangemount blower intermittent duty
- 105 CFM (3.0 m³/min) — achieves ISO 9094 four-air-change-in-four-minute purge requirement for single-engine compartments up to ~3 m³
- Flangemount — four-screw bulkhead attachment; 75 mm slip-on hose inlet
- Intermittent-duty motor — optimised for cycling operation, not sustained run; low current draw
- 12 V DC, 6.0 A; recommended fuse: 10 A
- Corrosion-resistant reinforced plastic housing — salt-air rated throughout
- NMMA Type Accepted — satisfies recreational vessel ventilation certification
Typical Applications
- Petrol engine compartment pre-purge on sailing yachts and motor sailers to 40 ft — ISO 9094 and ABYC A-24 mandate a minimum four-minute blower run before ignition in enclosed petrol engine spaces; at 105 CFM the 35115-0020 clears compartments up to 3 m³ well within that window
- Diesel pre-start bilge ventilation on small motor cruisers to 40 ft — clearing accumulated heat soak, residual diesel vapour, and moisture from enclosed bilge spaces before starting
- Tender and RIB engine bay purge — compact 75 mm footprint suits the tight engine bays of GRP and aluminium tenders with inboard petrol or diesel installations
- Generator compartment pre-start on smaller vessels — gas clearance on single genset installations where the compartment volume falls within the 35115-0020’s rated airflow
Centrifugal Blower vs Axial Fan
Centrifugal blowers are the right choice for restrictive ducting — runs with bends, grilles, deck fittings, and any meaningful hose length. Their static pressure characteristic maintains rated airflow against system resistance; the more restricted the duct, the more a centrifugal blower outperforms an axial fan. Axial fans are optimised for free-flowing installations — short, straight, low-restriction paths where they can move very high air volumes efficiently, but where duct resistance would significantly derate their output. For a typical yacht engine room with a louvred intake, a 3–8 m hose run, and two or three bends, a centrifugal blower is the correct tool. When compartment size demands airflow beyond 250 CFM per position, or where the installation allows a near-straight bulkhead-to-bulkhead run, the Centek axial range is the step up.
Installation & Compatibility Notes
- Intermittent duty only — not rated for sustained continuous operation; for continuous engine-room ventilation use the Jabsco 34739 series (150 CFM, continuous duty)
- Flangemount to flat bulkhead; 75 mm slip-on hose on inlet; discharge open to compartment or connected to separate extract duct
- For petrol engine spaces requiring formal ignition protection to SAE J1171 / ISO 8846, confirm compliance with the relevant survey authority before installation; NMMA Type Acceptance addresses recreational vessel requirements
- For engine compartments above 3 m³, pair two units or step up to the 150 CFM 34739 series