Jabsco 240V AC Macerator Pump — Dockside / Commercial

$2,439.00

Jabsco 240V/50Hz AC macerator pump for heavy-duty commercial or dockside waste pump-out. 53 LPM open flow / 44 LPM @ 3m head. Self-priming to 1.2m. Thermal overload protected. 38mm barb and 1½” NPT inlet, 25mm (1″) outlet. Handles hard and soft solids.

Add to Quote
SKU: J11-113 Category:

Description

Jabsco 240V Macerator Pump — Dockside / Commercial

The Jabsco 240V AC macerator pump is the heavy-duty, mains-powered choice for commercial and dockside waste pump-out — grinding black-water waste through a stainless cutter and pumping it overboard or to a dockside pump-out. Running on 240 V / 50 Hz, it delivers 53 L/min open flow (44 L/min @ 3 m head), self-primes to 1.2 m and handles hard and soft solids. The continuously-rated AC motor is thermal-overload protected for the repeated pump-out cycles of a marina, workboat or shore installation where DC supply isn’t the limiting factor.

Specifications

Spec Value
Flow 53 L/min open · 44 L/min @ 3 m head
Cutter Stainless — handles hard & soft solids
Inlet 1½” (38 mm) hose barb over a 1½” NPT male thread
Outlet 1″ (25 mm) hose barb
Priming Self-priming to 1.2 m
Supply 240 V / 50 Hz AC — thermal overload protected
Duty Heavy / repeated pump-out cycles

What it’s for — emptying a holding tank

The macerator draws from the black-water holding tank (or a macerating toilet) and discharges it one of two ways:

  • Overboard — macerated and pumped straight out through a skin fitting, where discharge is legally permitted.
  • To a dockside pump-out — pumped up to a deck pump-out fitting for shore reception — the usual duty for a marina or commercial installation.

⚠️ Discharge is regulated — read before plumbing overboard

Discharging untreated black water overboard is restricted by law — MARPOL Annex IV internationally, plus national and local rules and no-discharge zones. In many waters you may only discharge a set distance offshore (or not at all), and inside marinas, harbours and protected areas you must pump out to shore. Always plumb the system so waste can go to a holding tank / deck pump-out, and only fit and use the overboard path where it is legal to do so. Check the rules for your waters and flag state before relying on overboard discharge. This is general guidance, not legal advice.

Selecting overboard or pump-out — fit a diverter valve

To choose between the two discharge routes from one pump, fit a Jabsco Y-Valve waste diverter (45490-1000) on the discharge: one lever sends flow overboard or to the deck pump-out. The Y-Valve ships with 1½” ports and an extra 1″ (25 mm) barbed port that matches this pump’s 1″ outlet. Two caveats: make sure the diverter is rated for the macerator’s discharge pressure, and fit a vented loop above the waterline on the overboard leg to stop back-siphon.

Port & plumbing mechanics

  • Inlet — 1½” (38 mm): a moulded hose barb stepped over a 1½” NPT male thread. Either push 38 mm bore sanitation hose over the barb and double-clamp it, or, to screw on a threaded fitting (hose tail, adapter or valve), cut the moulded barb back to the thread and thread on a 1½” NPT male fitting. (Jabsco ports are NPT — use an NPT fitting, or an NPT–BSP adapter if your plumbing is BSP.)
  • Outlet — 1″ (25 mm): a 1″ hose barb — run 25 mm bore discharge hose, double-clamped, up to a vented loop and then to the skin fitting or diverter.
  • Use proper sanitation hose throughout to avoid odour permeation, and keep the discharge run as short and straight as practical.

240V AC or the DC macerator?

  • This 240 V AC pump — for commercial, dockside and shore installations, and vessels with reliable mains or genset AC. Heavier motor, higher flow, built for frequent heavy-duty pump-out.
  • Run-dry DC macerator (12 / 24 V) — for vessels pumping out on the house battery bank, with patented run-dry protection for the normal tank pump-down.

Installation & dealer notes

  • 240 V wiring — licensed electrician only. Install on an RCD-protected circuit, correctly isolated and earthed; AC in a marine space must be fitted to standard.
  • Vented loop on the discharge, above the waterline — mandatory on an overboard leg to prevent back-siphon / down-flooding.
  • Mount above / beside the tank so it self-primes; keep the suction short.
  • Don’t run it dry for long. Thermal overload protects the motor from overrun — switch off once the tank is empty; let it cool between long pump-outs.

Common faults

  • Trips / stops: thermal overload from over-long running or a seized / jammed cutter.
  • Runs but won’t clear: air-locked or blocked discharge, or a dull cutter.
  • Lost prime / weak flow: suction air leak or a blocked inlet.

Key features

  • 240 V / 50 Hz AC — mains / genset powered, heavy-duty
  • 53 L/min open; 44 L/min @ 3 m head
  • Stainless cutter — hard & soft solids; self-priming to 1.2 m
  • Thermal-overload-protected continuous-rated motor
  • 1½” NPT/barb inlet · 1″ barb outlet
  • Overboard or dockside pump-out — pair with a Jabsco Y-Valve diverter

Genuine Jabsco (Xylem). Supplied by Y3 Marine.

Additional information

Type

240V AC waste macerator pump — commercial / dockside

Flow

53 L/min open · 44 L/min @ 3 m

Cutter

Stainless — hard & soft solids

Inlet

1½" (38 mm) barb over 1½" NPT male thread

Outlet

1" (25 mm) hose barb

Priming

Self-priming to 1.2 m

Supply

240 V / 50 Hz AC · thermal overload protected

Duty

Heavy / repeated pump-out

Discharge

Overboard (where legal) or dockside pump-out · pair with Jabsco Y-Valve diverter

Wiring

240V — licensed electrician · RCD-protected

Brand