Jabsco 100mm Flangemount Blower — Standard

The Jabsco 35400 series is a 250 CFM (7.1 m³/min) 4″ flangemount blower for engine room ventilation, generator space exhaust, and machinery compartment air exchange on motor cruisers and sportfishers up to approximately 80 ft. A matched supply-and-extract pair delivers 850 m³/hr — achieving 10 ACH for diesel compartments up to ~42 m³ — and the 100 mm duct connection handles the higher airflow demands of twin-engine and larger single-diesel installations where the 3″ range falls short. The right choice for leisure and charter yachts with typical engine hours under 8 hours daily; step up to the heavy duty 35760 for passagemakers and live-aboards running blowers 10+ hours daily in hot engine rooms. Ignition-protected to USCG 183.410 and ISO 8846 — certified safe for enclosed fuel compartments and spaces where flammable vapours may accumulate. Available in 12V and 24V DC.

Add to Quote
SKU: N/A Category:

Description

The Jabsco 100mm flangemount blower standard (35400 series) is the most widely fitted centrifugal ventilator on production motor cruisers and sportfishers in the 45–80 ft bracket. Delivering 250 CFM (7.1 m³/min) through 100 mm ducting, a matched supply-and-extract pair provides 850 m³/hr — sufficient to achieve the 10 air changes per hour working minimum for diesel engine compartments up to approximately 42 m³. That covers twin-engine installations and larger single-diesel compartments where the 75mm range no longer has the airflow to maintain adequate temperatures. Four-screw bulkhead mount, single 100 mm slip-on inlet, NMMA Type Accepted. Available in 12 V and 24 V DC.

Ignition-protected to USCG 183.410 and ISO 8846 — certified safe for enclosed fuel compartments and spaces where flammable vapours may accumulate.

Key features — Jabsco 100mm flangemount blower standard

  • 250 CFM (7.1 m³/min) — matched pair delivers 850 m³/hr; 10 ACH for diesel compartments up to ~42 m³
  • Flangemount — four-screw bulkhead attachment; single 100 mm slip-on inlet hose connection
  • Continuous-duty rated motor
  • 12 V DC: 12.0 A, 15 A fuse / 24 V DC: 5.3 A
  • Corrosion-resistant reinforced plastic housing; 2.7 kg (6 lb)
  • NMMA Type Accepted

Typical Applications

  • Twin-engine diesel compartments on motor cruisers 45–80 ft — standard supply-and-extract configuration; one blower each side drawing air across both engines, exhausting hot air overboard; 850 m³/hr pair output satisfies ventilation requirements for most engine rooms in this bracket
  • High-output single-engine diesel installations on motor cruisers to 80 ft — where engine power output and compartment heat rejection exceed the capacity of the 75mm range
  • Generator room ventilation on 45–80 ft vessels — sustained supply and extract across a main genset compartment within the 42 m³ capacity envelope
  • Utility and auxiliary compartment ventilation on larger vessels — bilge pump rooms, steering gear spaces, and auxiliary machinery compartments on vessels beyond 70 ft where airflow demand is modest

Centrifugal Blower vs Axial Fan

Centrifugal blowers are the right choice for restrictive ducting — runs with bends, grilles, deck fittings, and any meaningful hose length. Their static pressure characteristic maintains rated airflow against system resistance; the more restricted the duct, the more a centrifugal blower outperforms an axial fan. Axial fans are optimised for free-flowing installations — short, straight, low-restriction paths where they can move very high air volumes efficiently, but where duct resistance would significantly derate their output. For a typical yacht engine room with a louvred intake, a 3–8 m hose run, and two or three bends, a centrifugal blower is the correct tool. When compartment size demands airflow beyond 250 CFM per position, or where the installation allows a near-straight bulkhead-to-bulkhead run, the Centek axial range is the step up.

Installation & Compatibility Notes

  • Run as a matched supply-and-extract pair; size the duct to maintain face velocity below 8 m/s to limit noise and pressure drop
  • 12 V variant draws 12 A — confirm bus capacity where two units run simultaneously; 24 V DC reduces current draw to 5.3 A per blower
  • For compartments above ~42 m³ or vessels above 80 ft requiring more airflow per blower position, multiple units or the Centek axial range are the correct step up
  • For demanding long-passage and live-aboard duty, consider upgrading to the heavy-duty 35760 series with reinforced motor windings

Additional information

Configuration

12V DC, 24V DC

Brand

Jabsco

Series

35400

Mount Type

Flangemount

Hose Connection

100 mm (4") — inlet only

Airflow

250 CFM (7.1 m³/min)

Duty Rating

Continuous

Current Draw

12.0 A (12V DC) / 5.3 A (24V DC)

Weight

2.7 kg (6 lb)

Certification

NMMA Type Accepted — Ignition Protected (USCG 183.410 / ISO 8846)

Housing

Corrosion-resistant reinforced plastic