Description
The Jabsco 100mm flangemount blower heavy duty (35760 series) — same 250 CFM (7.1 m³/min) airflow and 100 mm duct connection as the standard 35400, but with a reinforced motor featuring heavier copper windings and a higher-rated bearing assembly. In supply-and-extract configuration a matched pair delivers 850 m³/hr, achieving the 10 air changes per hour working minimum for diesel engine compartments up to ~42 m³ on motor cruisers and long-range motor sailors in the 45–80 ft bracket. The heavier motor rating is what matters on a passagemaker running 10–16 hours daily with engine-room ambients sustained above 50 °C — conditions where a standard-duty motor degrades rapidly. Four-screw bulkhead mount, single 100 mm slip-on inlet. Available in 12 V and 24 V DC.
Ignition-protected to USCG 183.410 and ISO 8846 — certified safe for enclosed fuel compartments and spaces where flammable vapours may accumulate.
Key features — Jabsco 100mm flangemount blower heavy duty
- Heavy-duty motor — reinforced copper windings and higher-rated bearing assembly for sustained operation at elevated ambient temperatures
- 250 CFM (7.1 m³/min) — matched pair delivers 850 m³/hr; 10 ACH for diesel compartments up to ~42 m³
- Flangemount — four-screw bulkhead attachment; single 100 mm slip-on inlet
- 12 V DC: 11.0 A / 24 V DC available
- Continuous duty — rated for full-passage engine-room operation without cycling
- Corrosion-resistant reinforced plastic housing; 1.8 kg (4 lb); NMMA Type Accepted
Typical Applications
- Long-passage and bluewater motor vessels 45–80 ft — where blowers run 10–16 hours daily and sustained engine-room temperatures above 50 °C expose standard-duty motors to accelerated winding degradation; the 35760 is built with the thermal margin to run the passage
- Live-aboard vessels with continuous generator operation — where the machinery rarely cools between uses and blower duty cycles approach 24 hours
- Twin-engine extract on motor cruisers 45–80 ft — the extract blower operates against the engine heat plume and in the highest ambient of the pair; upgrading the extract position to heavy-duty while leaving supply on standard duty is a common approach
- Superyacht tender and chase vessel engine rooms — where the tender works hard and blower reliability matters more than first cost
Centrifugal Blower vs Axial Fan
Centrifugal blowers are the right choice for restrictive ducting — runs with bends, grilles, deck fittings, and any meaningful hose length. Their static pressure characteristic maintains rated airflow against system resistance; the more restricted the duct, the more a centrifugal blower outperforms an axial fan. Axial fans are optimised for free-flowing installations — short, straight, low-restriction paths where they can move very high air volumes efficiently, but where duct resistance would significantly derate their output. For a typical yacht engine room with a louvred intake, a 3–8 m hose run, and two or three bends, a centrifugal blower is the correct tool. When compartment size demands airflow beyond 250 CFM per position, or where the installation allows a near-straight bulkhead-to-bulkhead run, the Centek axial range is the step up.
Installation & Compatibility Notes
- Direct replacement for the standard 35400 series — same flangemount footprint and 100 mm inlet; no duct or bulkhead modifications required
- 12 V variant draws 11 A at full load — confirm bus capacity where two units run simultaneously; 24 V DC halves current draw per blower
- For equivalent heavy-duty performance in a flexible installation, see the 100mm Heavy-Duty Flexmount (35770 series)