Description
The Isotherm Slim Square marine water heater is a space-saving unit built around a slim, flat-profile tank that mounts hard against a bulkhead where a cylindrical unit won’t fit. At just 183 mm deep it suits tight lazarettes and lockers, while still delivering a full 16 L (4.2 gal) of hot water via both a 240V/115V electric element and an engine heat exchanger. AISI 316 stainless tank, thermostatic mixing valve included, and Australian Standards approved.
Key features of the Isotherm Slim Square marine water heater
- Slim, flat ‘Square’ profile — only 183 mm deep for bulkhead mounting
- AISI 316 acid-resistant stainless-steel inner tank
- Brushed stainless-steel outer casing
- Corrugated engine heat-exchanger coil for free hot water underway
- Plug-and-play 750W immersion element (240V or 115V)
- Thermostatic mixing valve included
- 5.0 bar / 70 psi safety valve
- Ultra-thick insulation for low standing heat loss
- 360° adjustable stainless feet — mounts on the flat or on a bulkhead
- 5-year limited tank warranty
Why ‘Slim Square’
The whole point of the Square is packaging. A cylindrical calorifier needs clear radial space; the Slim Square’s flat back and shallow 183 mm depth let it sit against a bulkhead or in a narrow void, freeing usable stowage. For a 16 L unit it is one of the easiest heaters to install in a tight boat.
How it works — dual heating
Like all quality marine calorifiers it heats two ways: the electric element on shore power or generator, and the engine heat exchanger, which recovers waste heat from the cooling circuit to give free hot water on passage with nothing running but the main engine. Choose 240V for Australian systems or 115V for US-spec / 60Hz vessels.
Temperature & Legionella control
Store the water hot (60°C+) to suppress Legionella, then rely on the supplied thermostatic mixing valve to temper delivery to a safe ≤50°C at the outlets. A hotter store also stretches your usable hot water, since each litre of stored water blends into more litres of warm water at the tap.
Maintenance & genuine spares
To get the full service life, service the wear items and keep to genuine Isotherm parts:
- Renew the immersion element if it fails or scales
- Replace the pressure relief valve if it weeps or seizes
- Service the thermostatic mixing valve as needed
Scaling up — multiple heaters in parallel or series
On larger vessels where a single tank can’t meet demand, calorifiers are installed in multiples:
- Parallel — two or more tanks share a common cold feed and combined hot outlet, storing and delivering hot water at the same time. This roughly multiplies both the stored volume and the peak simultaneous draw — the usual choice for several bathrooms drawing at once. For it to balance, the tanks must be equally matched (same capacity and rating) and set to the same temperature, with equal-length or reverse-return pipework so they draw and refill evenly. Each tank keeps its own relief valve and expansion provision.
- Series — the hot outlet of one tank feeds the cold inlet of the next, so the first pre-heats and the second brings the water to final temperature. The two tanks needn’t match: you can run the first (pre-heat) tank cooler and the second (final) tank hotter, and the second stage can even be a smaller tank, since it only has to lift already-warmed water the last step. The classic use is an engine heat-exchanger tank pre-heating water that then passes to an electric tank for final heating — recovering free engine heat while guaranteeing delivery temperature alongside. Series extends continuous draw but does not add simultaneous flow the way parallel does.
Match the layout to the load: parallel for peak simultaneous demand, series for pre-heat and sustained draw. Size and configure to the vessel’s hot-water demand, and confirm with your surveyor on commercial and passenger vessels.
Hot water circulation loops
On a vessel with long pipe runs, hot water can take a while to reach distant heads and galleys — you run the tap and wait, wasting time and precious fresh water. A hot water circulation loop fixes this: a circulation pump continuously moves hot water from the calorifier around the system and back via a return line, so hot water is available instantly at every outlet. It also keeps the whole system at temperature with no dead legs — good practice for Legionella control. Use a bronze or stainless circulation pump rated for potable hot water — such as the Calpeda NCE energy-saving circulation pump — controlled by a timer or thermostat to save energy, and insulate the loop.
Design & installation — we can help
Y3 Marine can design and install your complete hot-water system — sizing the calorifier(s), circulation loop, tempering and safety valves, and pump selection to suit your vessel and demand. Contact us to discuss your installation.
⚠ Australian Installation Requirements
Marine water heaters on vessels in Australian waters must comply with the following. Failure to comply may constitute a vessel safety deficiency under the National Standard for Commercial Vessels (NSCV C5A).
- Temperature & Pressure Relief Valve: must be rated and certified to AS/NZS 1271. Confirm compliance with your marine surveyor before commissioning.
- Thermostatic Mixing Valve (TMV): required at hot-water outlets to prevent scalding — a thermostatic mixing valve is supplied with this unit.
Installation is the responsibility of the installer and vessel operator. Y3 Marine recommends a licensed marine plumber and electrician.