Description
📦 Dispatch & Availability: This item is available on back order. Please allow up to 10 business days to dispatch from the date of order.
The Isotherm Basic marine water heater is a premium cylindrical unit with a brushed stainless steel exterior and innovative internal design. Available in four capacities from 24 to 75 litres, it suits everything from a day boat galley to a larger cruising yacht. The wider diameter format (395 mm) delivers greater volume in a shorter overall length compared to the Slim series.
The heating elements and engine heat exchanger coil are positioned at the lowest point of the tank, where water is coldest, ensuring even heating throughout the full tank volume. Specially designed water inlets and outlets minimise mixing of hot and cold water for efficient heat retention.
Key features of the Isotherm Basic marine water heater
- AISI 316 stainless steel tank — superior corrosion resistance in the marine environment
- No sacrificial anode to check or replace — the AISI 316 stainless tank will not rust from within the way a glass-lined steel tank can
- Brushed AISI 304 stainless steel outer casing and fixing feet
- Extra-long corrugated engine heat exchanger coil — provides hot water underway or when shore power is unavailable
- 750W plug-and-play immersion heating element (240V AC); 1200W and 2000W options available for 40L, 50L and 75L models
- Ultra-thick CFC-free polyurethane insulation for minimal heat loss
- 5.0 bar / 70 psi safety valve with simple winter drain function
- Thermostatic mixing valve fitted as standard — prevents scalding, delivers consistent hot water temperature
- 360° adjustable mounting feet — mounts vertically, horizontally, or at any angle
- ¾” BSP water connections
- 5-year Limited Warranty on tank; 2-year warranty on unit
- Australian Standards Approved (240V)
Choosing your size & format
The Basic is Isotherm’s wider (395 mm) format — more volume in a shorter overall length. Pick the capacity to match your crew and demand:
- 24 L: day boats and small cruisers — a couple, galley and one head
- 40 L: cruising yachts around 35–45 ft — a couple or small family
- 50 L: cruising yachts to around 50 ft — comfortable back-to-back showers
- 75 L: larger yachts up to around 60 ft — several outlets drawing at once
Need a narrower unit for a tight space? See the Slim (295 mm) format; for a flat bulkhead-mounting profile, see the Slim Square. As a general rule of thumb allow roughly 20–30 L of tank per person aboard for comfortable hot water, and step up a size if you run several outlets back-to-back. On the larger models a higher-output element is available for faster recovery (see the element listing for fitment).
How it works — dual heating
The Isotherm heats two ways: the 240V element on shore power or generator, and the engine heat exchanger coil, which recovers waste heat from the cooling circuit for free hot water underway. Isotherm positions both the element and the coil at the lowest point of the tank — where the water is coldest — so the full volume heats evenly rather than just the top.
Temperature, Legionella & usable capacity
Store the water hot (60°C+) to suppress Legionella, and rely on the thermostatic mixing valve fitted as standard to temper delivery to a safe ≤50°C at the outlets. A hotter store also stretches your hot water: because stored hot water blends with cold to reach a usable temperature, each litre of stored water yields more litres of warm water — effectively increasing capacity without a bigger tank.
Maintenance & genuine spares
The AISI 316 stainless tank resists corrosion without the sacrificial anode a glass-lined steel tank needs, so upkeep is minimal — keep to genuine Isotherm parts for the wear items:
- Renew the immersion element if it fails or scales (fit a new gasket set at the same time)
- Replace the pressure relief valve if it weeps or seizes
- Renew the operating thermostat or overheat thermostat if temperature control fails
- Service the thermostatic mixing valve as needed
Scaling up — multiple heaters in parallel or series
On larger vessels where a single tank can’t meet demand, calorifiers are installed in multiples:
- Parallel — two or more tanks share a common cold feed and combined hot outlet, storing and delivering hot water at the same time. This roughly multiplies both the stored volume and the peak simultaneous draw — the usual choice for several bathrooms drawing at once. For it to balance, the tanks must be equally matched (same capacity and rating) and set to the same temperature, with equal-length or reverse-return pipework so they draw and refill evenly. Each tank keeps its own relief valve and expansion provision.
- Series — the hot outlet of one tank feeds the cold inlet of the next, so the first pre-heats and the second brings the water to final temperature. The two tanks needn’t match: you can run the first (pre-heat) tank cooler and the second (final) tank hotter, and the second stage can even be a smaller tank, since it only has to lift already-warmed water the last step. The classic use is an engine heat-exchanger tank pre-heating water that then passes to an electric tank for final heating — recovering free engine heat while guaranteeing delivery temperature alongside. Series extends continuous draw but does not add simultaneous flow the way parallel does.
Match the layout to the load: parallel for peak simultaneous demand, series for pre-heat and sustained draw. Size and configure to the vessel’s hot-water demand, and confirm with your surveyor on commercial and passenger vessels.
Hot water circulation loops
On a vessel with long pipe runs, hot water can take a while to reach distant heads and galleys — you run the tap and wait, wasting time and precious fresh water. A hot water circulation loop fixes this: a circulation pump continuously moves hot water from the calorifier around the system and back via a return line, so hot water is available instantly at every outlet. It also keeps the whole system at temperature with no dead legs — good practice for Legionella control. Use a bronze or stainless circulation pump rated for potable hot water — such as the Calpeda NCE energy-saving circulation pump — controlled by a timer or thermostat to save energy, and insulate the loop.
Design & installation — we can help
Y3 Marine can design and install your complete hot-water system — sizing the calorifier(s), circulation loop, tempering and safety valves, and pump selection to suit your vessel and demand. Contact us to discuss your installation.
⚠ Australian Installation Requirements
All marine water heaters installed aboard vessels in Australian waters must comply with the following requirements. Failure to comply may constitute a vessel safety deficiency under the National Standard for Commercial Vessels (NSCV C5A).
- Temperature & Pressure Relief Valve (T&PRV): A T&PRV rated and certified to AS/NZS 1271 must be fitted to this unit. CE-marked or international relief valves do not automatically satisfy this requirement for Australian domestic commercial vessels. Confirm compliance with your marine surveyor before commissioning.
- Thermostatic Mixing Valve (TMV): A thermostatic mixing valve must be installed at all hot water outlets. The TMV limits delivery temperature to prevent scalding and is required as a safety measure on all commercial and passenger vessels.
Compliance is the responsibility of the installer and vessel operator. Y3 Marine recommends installation by a licensed marine plumber or qualified engineer.