Description
The Gianneschi VCR is the backward-curved heavy-duty centrifugal marine blower — the high-efficiency choice when the duct run fights back. The backward-curved impeller reaches higher pressure and delivery than a forward-curved fan and runs a non-overloading power curve, so the motor stays within its rating as system resistance changes. Purpose-built for engine-room ventilation and harmful-gas extraction on yachts and commercial vessels.
Key features of the Gianneschi VCR
- Backward-curved steel impeller — high efficiency, high pressure, low noise
- Steel spiral (scroll) casing; stainless casing / impeller on request
- Non-overloading characteristic — stable motor load across the duty range
- Handles clean or slightly dusty air up to 80 °C; suited to harmful-gas extraction
- Voltages: 12–24 V DC; 230 V 1~ 50 Hz / 208–240 V 1~ 60 Hz; 230/400 V 3~ 50 Hz / 208–240 / 360–400 V 3~ 60 Hz
- Class F insulation; IP22 (DC) / IP44–55 (AC)
- No-spark / ATEX motor option for fuel-vapour zones
- Models VCR 352, 402, 452, 502, 562, 632, 712 (indicative — confirm current range at quote)
Typical Superyacht Applications
- Heavy-duty engine-room supply / extraction with real back-pressure
- Long or restrictive ducted runs where a forward-curved fan runs out of pressure
- Galley / kitchen-hood and toilet extraction; technical rooms and harmful-gas removal
Model line-up
The backward-curved VCR reaches higher pressure and delivery than the forward-curved VCP for a given frame. Frames rise in size and connection diameter from the 352 to the 712, and most come in several motor / speed variants (930–2800 rpm): the smaller frames (352–452) include high-speed 2800 rpm builds that give very high free-air flow, while the larger frames (502–712) run slower and are built to hold high static pressure. As with the VCP, the max delivery below — indicative free-air figures from the factory datasheet (Ed. 10/2009) — does not simply climb with frame size; choose by your flow-and-pressure duty and confirm at quote.
| Model | Motor (kW)1 | Speed (rpm) | Connection Ø | Max delivery2 |
|---|---|---|---|---|
| VCR 352 | 0.25–3.0 | 1450–2800 | 360 mm | ~190 m³/min |
| VCR 402 | 0.55–5.5 | 1450–2800 | 405 mm | ~230 m³/min |
| VCR 452 | 0.75–11 | 1450–2800 | 455 mm | ~300 m³/min |
| VCR 502 | 0.37–2.2 | 1450 | 505 mm | ~88 m³/min |
| VCR 562 | 0.75–4.0 | 930–1450 | 566 mm | ~112 m³/min |
| VCR 632 | 1.4–7.5 | 930–1450 | 636 mm | ~150 m³/min |
| VCR 712 | 3.0–4.0 | 930 | 716 mm | ~80 m³/min |
1 Installed-power range across the frame’s motor / speed variants (12–24 V DC and 1~/3~ AC available). 2 Indicative free-air delivery; the VCR holds delivery to much higher duct pressures than the VCP. Confirm duty at quote.
Configuration options
- Model — the frame size; sets airflow and pressure.
- Power Supply — 12/24 V DC or single/three-phase AC, 50 or 60 Hz (at 60 Hz the AC options run in the 208–240 V band).
- Motor — Standard, or No-spark / ATEX Ex-rated for spaces where fuel vapour or an explosive atmosphere may be present.
- Impeller Material — steel (standard) or stainless steel for greater corrosion resistance.
- Mounting — wall (bulkhead), roof / deckhead, or in-line within a duct run — pick to suit where the blower sits.
Installation & Compatibility Notes
- Configure-to-order: specify model, size, duty (m³/min @ mmH₂O), voltage/phase/Hz, mounting (wall / roof / in-line), motor type and impeller material
- Need maximum air-flow rather than pressure? Choose the forward-curved Gianneschi VCP. For lighter standard-duty extraction, the C series is the compact alternative.
- Pair with the Gianneschi Control Fan (G-Touch) VFD system for variable-speed control; add silencers / anti-vibration rings as needed